Improved ECG‐gated cardiac cine imaging with variable initial value based tiny golden‐angle radial trajectory.

Saved in:
Bibliographic Details
Title: Improved ECG‐gated cardiac cine imaging with variable initial value based tiny golden‐angle radial trajectory.
Authors: Hu, Jiaojiao1 (AUTHOR), Hao, Xiaohan1 (AUTHOR), Zhang, Huabin1 (AUTHOR), Zhou, Jiantai1 (AUTHOR), Wang, Yanming1 (AUTHOR), He, Kewu2 (AUTHOR), Sun, Li3 (AUTHOR), Ji, Yang4 (AUTHOR) jiyang@ustc.edu.cn, Qiu, Bensheng1 (AUTHOR) bqiu@ustc.edu.cn
Source: Medical Physics. Dec2024, Vol. 51 Issue 12, p9155-9165. 11p.
Subjects: Cardiac magnetic resonance imaging, Golden ratio, Cardiac imaging, Statistical significance, Standard deviations
Abstract: Background: Breath‐held electrocardiogram‐gated cardiac cine imaging (ECG‐CINE), as the gold standard for assessing cardiac function in magnetic resonance imaging (MRI), is prone to motion artifacts. Conventional golden‐angle (CGA) sampling has emerged as a promising technique for mitigating motion effects in real‐time cardiac cine imaging. However, in ECG‐CINE, the irregular re‐binning of radial k‐space profiles based on CGA can exacerbate k‐space non‐uniformity, resulting in severe streaking artifacts. The recently introduced segmented golden‐angle ratio (SGA) scheme aims to solve this problem; nevertheless, it sacrifices the desired motion insensitivity. Purpose: The study aims to develop a more efficient k‐space sampling scheme for ECG‐CINE that guarantees both improved motion insensitivity and optimized k‐space coverage. Method: Theoretically, to enhance motion insensitivity, it is essential that the single‐frame radial k‐space profiles acquired within each heartbeat (HB) span as close to a full 360‐degree range as possible. Meanwhile, to ensure uniform data coverage, the sequentially acquired k‐space profiles need to be evenly distributed both within each HB and across multiple HBs. In this study, we propose a Variable Initial value‐based tiny Golden‐Angle radial trajectory (VIGA) to achieve these two goals. Specifically, VIGA is a two‐step approach: First, the tiny golden‐angle ratio is applied to the k‐space profiles within each HB to maintain motion insensitivity and k‐space uniformity as in CGA. Second, a golden ratio of the golden angle used within each HB is applied to the initial k‐space profiles across adjacent HBs to optimize coverage further. We validated the proposed VIGA method through numerical simulations, phantom experiments, and prospective and retrospective in vivo cardiac cine experiments. Results: Numerical simulations revealed that the k‐space uniformity of CGA is highly dependent on the number of spokes per HB, whereas VIGA and SGA maintained nearly optimal k‐space coverage regardless of this parameter. Both phantom and prospective studies demonstrated that VIGA outperforms CGA when the number of spokes per HB is suboptimal, and surpasses SGA in conditions with residual respiratory motion. The standard deviation of gradient scores indicates statistical significance between CGA and VIGA under free‐breathing conditions (p = 0.039) and between SGA and VIGA under all conditions tested (Free‐breathing, 200 spokes/HB: p = 0.028; Breath‐holding, 200 spokes/HB: p = 0.008; Free‐breathing, 200 spokes/HB: p = 0.013; Breath‐holding, 200 spokes/HB: p = 0.011). Retrospective results demonstrated that doctor ratings for SGA were lower than those for VIGA, and the ratings for systole images using VIGA were significantly higher than those using CGA (2.55 ± 0.45 vs. 3.29 ± 0.52; p = 0.04). Conclusion: A novel and efficient k‐space sampling scheme, named VIGA, was proposed to improve k‐space uniformity and motion insensitivity. VIGA facilitates robust image quality in both prospective and retrospective cardiac cine imaging, demonstrating its potential as a clinically viable alternative to CGA and SGA. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 181778090
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Improved ECG‐gated cardiac cine imaging with variable initial value based tiny golden‐angle radial trajectory.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Hu%2C+Jiaojiao%22">Hu, Jiaojiao</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Hao%2C+Xiaohan%22">Hao, Xiaohan</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Zhang%2C+Huabin%22">Zhang, Huabin</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Zhou%2C+Jiantai%22">Zhou, Jiantai</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Wang%2C+Yanming%22">Wang, Yanming</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22He%2C+Kewu%22">He, Kewu</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Sun%2C+Li%22">Sun, Li</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Ji%2C+Yang%22">Ji, Yang</searchLink><relatesTo>4</relatesTo> (AUTHOR)<i> jiyang@ustc.edu.cn</i><br /><searchLink fieldCode="AR" term="%22Qiu%2C+Bensheng%22">Qiu, Bensheng</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> bqiu@ustc.edu.cn</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Dec2024, Vol. 51 Issue 12, p9155-9165. 11p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Cardiac+magnetic+resonance+imaging%22">Cardiac magnetic resonance imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Golden+ratio%22">Golden ratio</searchLink><br /><searchLink fieldCode="DE" term="%22Cardiac+imaging%22">Cardiac imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Statistical+significance%22">Statistical significance</searchLink><br /><searchLink fieldCode="DE" term="%22Standard+deviations%22">Standard deviations</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Background: Breath‐held electrocardiogram‐gated cardiac cine imaging (ECG‐CINE), as the gold standard for assessing cardiac function in magnetic resonance imaging (MRI), is prone to motion artifacts. Conventional golden‐angle (CGA) sampling has emerged as a promising technique for mitigating motion effects in real‐time cardiac cine imaging. However, in ECG‐CINE, the irregular re‐binning of radial k‐space profiles based on CGA can exacerbate k‐space non‐uniformity, resulting in severe streaking artifacts. The recently introduced segmented golden‐angle ratio (SGA) scheme aims to solve this problem; nevertheless, it sacrifices the desired motion insensitivity. Purpose: The study aims to develop a more efficient k‐space sampling scheme for ECG‐CINE that guarantees both improved motion insensitivity and optimized k‐space coverage. Method: Theoretically, to enhance motion insensitivity, it is essential that the single‐frame radial k‐space profiles acquired within each heartbeat (HB) span as close to a full 360‐degree range as possible. Meanwhile, to ensure uniform data coverage, the sequentially acquired k‐space profiles need to be evenly distributed both within each HB and across multiple HBs. In this study, we propose a Variable Initial value‐based tiny Golden‐Angle radial trajectory (VIGA) to achieve these two goals. Specifically, VIGA is a two‐step approach: First, the tiny golden‐angle ratio is applied to the k‐space profiles within each HB to maintain motion insensitivity and k‐space uniformity as in CGA. Second, a golden ratio of the golden angle used within each HB is applied to the initial k‐space profiles across adjacent HBs to optimize coverage further. We validated the proposed VIGA method through numerical simulations, phantom experiments, and prospective and retrospective in vivo cardiac cine experiments. Results: Numerical simulations revealed that the k‐space uniformity of CGA is highly dependent on the number of spokes per HB, whereas VIGA and SGA maintained nearly optimal k‐space coverage regardless of this parameter. Both phantom and prospective studies demonstrated that VIGA outperforms CGA when the number of spokes per HB is suboptimal, and surpasses SGA in conditions with residual respiratory motion. The standard deviation of gradient scores indicates statistical significance between CGA and VIGA under free‐breathing conditions (p = 0.039) and between SGA and VIGA under all conditions tested (Free‐breathing, 200 spokes/HB: p = 0.028; Breath‐holding, 200 spokes/HB: p = 0.008; Free‐breathing, 200 spokes/HB: p = 0.013; Breath‐holding, 200 spokes/HB: p = 0.011). Retrospective results demonstrated that doctor ratings for SGA were lower than those for VIGA, and the ratings for systole images using VIGA were significantly higher than those using CGA (2.55 ± 0.45 vs. 3.29 ± 0.52; p = 0.04). Conclusion: A novel and efficient k‐space sampling scheme, named VIGA, was proposed to improve k‐space uniformity and motion insensitivity. VIGA facilitates robust image quality in both prospective and retrospective cardiac cine imaging, demonstrating its potential as a clinically viable alternative to CGA and SGA. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=181778090
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mp.17417
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 11
        StartPage: 9155
    Subjects:
      – SubjectFull: Cardiac magnetic resonance imaging
        Type: general
      – SubjectFull: Golden ratio
        Type: general
      – SubjectFull: Cardiac imaging
        Type: general
      – SubjectFull: Statistical significance
        Type: general
      – SubjectFull: Standard deviations
        Type: general
    Titles:
      – TitleFull: Improved ECG‐gated cardiac cine imaging with variable initial value based tiny golden‐angle radial trajectory.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Hu, Jiaojiao
      – PersonEntity:
          Name:
            NameFull: Hao, Xiaohan
      – PersonEntity:
          Name:
            NameFull: Zhang, Huabin
      – PersonEntity:
          Name:
            NameFull: Zhou, Jiantai
      – PersonEntity:
          Name:
            NameFull: Wang, Yanming
      – PersonEntity:
          Name:
            NameFull: He, Kewu
      – PersonEntity:
          Name:
            NameFull: Sun, Li
      – PersonEntity:
          Name:
            NameFull: Ji, Yang
      – PersonEntity:
          Name:
            NameFull: Qiu, Bensheng
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 12
              Text: Dec2024
              Type: published
              Y: 2024
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 51
            – Type: issue
              Value: 12
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1