Intraoperative Ablation Control Based on Real-Time Necrosis Monitoring Feedback: Numerical Evaluation.
Saved in:
| Title: | Intraoperative Ablation Control Based on Real-Time Necrosis Monitoring Feedback: Numerical Evaluation. |
|---|---|
| Authors: | Murakami, Ryo1 (AUTHOR), Mori, Satoshi2 (AUTHOR), Zhang, Haichong K.1,3,4 (AUTHOR) hzhang10@wpi.edu |
| Source: | Annals of Biomedical Engineering. Dec2024, Vol. 52 Issue 12, p3312-3325. 14p. |
| Subjects: | Automatic control systems, Ablation techniques, Acoustic imaging, Finite element method, Robust control |
| Abstract: | Ablation therapy is a type of minimally invasive treatment, utilized for various organs including the brain, heart, and kidneys. The accuracy of the ablation process is critically important to avoid both insufficient and excessive ablation, which may result in compromised efficacy or complications. The thermal ablation is formulated by two theoretical models: the heat transfer (HT) and necrosis formation (NF) models. In modern medical practices, feed-forward (FF) and temperature feedback (TFB) controls are primarily used as ablation control methodologies. FF involves pre-therapy procedure planning based on previous experiences and theoretical knowledge without monitoring the intraoperative tissue response, hence, it can't compensate for discrepancies in the assumed HT or NF models. These discrepancies can arise due to individual patient's tissue characteristic differences and specific environmental conditions. Conversely, TFB control is based on the intraoperative temperature profile. It estimates the resulting heat damage based on the monitored temperature distribution and assumed NF model. Therefore, TFB can make necessary adjustments even if there is an error in the assumed HT model. TFB is thus seen as a more robust control method against modeling errors in the HT model. Still, TFB is limited as it assumes a fixed NF model, irrespective of the patient or the ablation technique used. An ideal solution to these limitations would be to actively monitor heat damage to the tissue during the operation and utilize this data to control ablation. This strategy is defined as necrosis feedback (NFB) in this study. Such real-time necrosis monitoring modalities making NFB possible are emerging, however, there is an absence of a generalized study that discusses the integration and quantifies the significance of the real-time necrosis monitor techniques for ablation therapy. Such an investigation is expected to clarify the universal principles of how these techniques would improve ablation therapy. In this study, we examine the potential of NFB in suppressing errors associated with the NF model as NFB is theoretically capable of monitoring and suppressing the errors associated with the NF models in its closed control loop. We simulate and compare the performances of TFB and NFB with artificially generated modeling errors using the finite element method (FEM). The results show that NFB provides more accurate ablation control than TFB when NF-oriented errors are applied, indicating NFB's potential to improve the ablation control accuracy and highlighting the value of the ongoing research to make real-time necrosis monitoring a clinically viable option. [ABSTRACT FROM AUTHOR] |
| Copyright of Annals of Biomedical Engineering is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 182280531 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Intraoperative Ablation Control Based on Real-Time Necrosis Monitoring Feedback: Numerical Evaluation. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Murakami%2C+Ryo%22">Murakami, Ryo</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Mori%2C+Satoshi%22">Mori, Satoshi</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Zhang%2C+Haichong+K%2E%22">Zhang, Haichong K.</searchLink><relatesTo>1,3,4</relatesTo> (AUTHOR)<i> hzhang10@wpi.edu</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Annals+of+Biomedical+Engineering%22">Annals of Biomedical Engineering</searchLink>. Dec2024, Vol. 52 Issue 12, p3312-3325. 14p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Automatic+control+systems%22">Automatic control systems</searchLink><br /><searchLink fieldCode="DE" term="%22Ablation+techniques%22">Ablation techniques</searchLink><br /><searchLink fieldCode="DE" term="%22Acoustic+imaging%22">Acoustic imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Finite+element+method%22">Finite element method</searchLink><br /><searchLink fieldCode="DE" term="%22Robust+control%22">Robust control</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Ablation therapy is a type of minimally invasive treatment, utilized for various organs including the brain, heart, and kidneys. The accuracy of the ablation process is critically important to avoid both insufficient and excessive ablation, which may result in compromised efficacy or complications. The thermal ablation is formulated by two theoretical models: the heat transfer (HT) and necrosis formation (NF) models. In modern medical practices, feed-forward (FF) and temperature feedback (TFB) controls are primarily used as ablation control methodologies. FF involves pre-therapy procedure planning based on previous experiences and theoretical knowledge without monitoring the intraoperative tissue response, hence, it can't compensate for discrepancies in the assumed HT or NF models. These discrepancies can arise due to individual patient's tissue characteristic differences and specific environmental conditions. Conversely, TFB control is based on the intraoperative temperature profile. It estimates the resulting heat damage based on the monitored temperature distribution and assumed NF model. Therefore, TFB can make necessary adjustments even if there is an error in the assumed HT model. TFB is thus seen as a more robust control method against modeling errors in the HT model. Still, TFB is limited as it assumes a fixed NF model, irrespective of the patient or the ablation technique used. An ideal solution to these limitations would be to actively monitor heat damage to the tissue during the operation and utilize this data to control ablation. This strategy is defined as necrosis feedback (NFB) in this study. Such real-time necrosis monitoring modalities making NFB possible are emerging, however, there is an absence of a generalized study that discusses the integration and quantifies the significance of the real-time necrosis monitor techniques for ablation therapy. Such an investigation is expected to clarify the universal principles of how these techniques would improve ablation therapy. In this study, we examine the potential of NFB in suppressing errors associated with the NF model as NFB is theoretically capable of monitoring and suppressing the errors associated with the NF models in its closed control loop. We simulate and compare the performances of TFB and NFB with artificially generated modeling errors using the finite element method (FEM). The results show that NFB provides more accurate ablation control than TFB when NF-oriented errors are applied, indicating NFB's potential to improve the ablation control accuracy and highlighting the value of the ongoing research to make real-time necrosis monitoring a clinically viable option. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Annals of Biomedical Engineering is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=182280531 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1007/s10439-024-03599-6 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 14 StartPage: 3312 Subjects: – SubjectFull: Automatic control systems Type: general – SubjectFull: Ablation techniques Type: general – SubjectFull: Acoustic imaging Type: general – SubjectFull: Finite element method Type: general – SubjectFull: Robust control Type: general Titles: – TitleFull: Intraoperative Ablation Control Based on Real-Time Necrosis Monitoring Feedback: Numerical Evaluation. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Murakami, Ryo – PersonEntity: Name: NameFull: Mori, Satoshi – PersonEntity: Name: NameFull: Zhang, Haichong K. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 12 Text: Dec2024 Type: published Y: 2024 Identifiers: – Type: issn-print Value: 00906964 Numbering: – Type: volume Value: 52 – Type: issue Value: 12 Titles: – TitleFull: Annals of Biomedical Engineering Type: main |
| ResultId | 1 |