Cantilever-based biaxial FBG inclinometer with low cross-axis sensitivity.

Saved in:
Bibliographic Details
Title: Cantilever-based biaxial FBG inclinometer with low cross-axis sensitivity.
Authors: RAMALINGAM, NIMALRAJH1, HANGTING YANG1, KOK-SING LIM1 kslim@um.edu.my, AHMAD, HARITH1,2
Source: Optica Applicata. 2024, Vol. 54 Issue 2, p189-203. 15p.
Subjects: Fiber Bragg gratings, Inclinometer, Cantilevers, Angles
Abstract: This work proposes and demonstrates a biaxial sensing inclinometer based on two FBGs surfacemounted on two separate thin cantilevers with a diminishable cross-axis sensitivity. The measured sensitivities for the inclination angles in the x-z plane and y-z plane are 34.87 and 33.49 pm/deg, respectively. To enhance the protection of the delicate FBGs and minimize axis-to-axis cross-sensitivity, the carbon-steel cantilevers are strategically arranged in a perpendicular configuration, resulting in an impressively low cross-sensitivity value of just 0.9275%. This alignment not only offers mechanical shielding but also ensures optimal performance and accuracy for the FBGs. [ABSTRACT FROM AUTHOR]
Copyright of Optica Applicata is the property of Oficyna Wydawnicza Politechniki Wroclawskiej and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 182918622
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Cantilever-based biaxial FBG inclinometer with low cross-axis sensitivity.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22RAMALINGAM%2C+NIMALRAJH%22">RAMALINGAM, NIMALRAJH</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22HANGTING+YANG%22">HANGTING YANG</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22KOK-SING+LIM%22">KOK-SING LIM</searchLink><relatesTo>1</relatesTo><i> kslim@um.edu.my</i><br /><searchLink fieldCode="AR" term="%22AHMAD%2C+HARITH%22">AHMAD, HARITH</searchLink><relatesTo>1,2</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Optica+Applicata%22">Optica Applicata</searchLink>. 2024, Vol. 54 Issue 2, p189-203. 15p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Fiber+Bragg+gratings%22">Fiber Bragg gratings</searchLink><br /><searchLink fieldCode="DE" term="%22Inclinometer%22">Inclinometer</searchLink><br /><searchLink fieldCode="DE" term="%22Cantilevers%22">Cantilevers</searchLink><br /><searchLink fieldCode="DE" term="%22Angles%22">Angles</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: This work proposes and demonstrates a biaxial sensing inclinometer based on two FBGs surfacemounted on two separate thin cantilevers with a diminishable cross-axis sensitivity. The measured sensitivities for the inclination angles in the x-z plane and y-z plane are 34.87 and 33.49 pm/deg, respectively. To enhance the protection of the delicate FBGs and minimize axis-to-axis cross-sensitivity, the carbon-steel cantilevers are strategically arranged in a perpendicular configuration, resulting in an impressively low cross-sensitivity value of just 0.9275%. This alignment not only offers mechanical shielding but also ensures optimal performance and accuracy for the FBGs. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Optica Applicata is the property of Oficyna Wydawnicza Politechniki Wroclawskiej and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=182918622
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.37190/oa240206
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 15
        StartPage: 189
    Subjects:
      – SubjectFull: Fiber Bragg gratings
        Type: general
      – SubjectFull: Inclinometer
        Type: general
      – SubjectFull: Cantilevers
        Type: general
      – SubjectFull: Angles
        Type: general
    Titles:
      – TitleFull: Cantilever-based biaxial FBG inclinometer with low cross-axis sensitivity.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: RAMALINGAM, NIMALRAJH
      – PersonEntity:
          Name:
            NameFull: HANGTING YANG
      – PersonEntity:
          Name:
            NameFull: KOK-SING LIM
      – PersonEntity:
          Name:
            NameFull: AHMAD, HARITH
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 04
              Text: 2024
              Type: published
              Y: 2024
          Identifiers:
            – Type: issn-print
              Value: 00785466
          Numbering:
            – Type: volume
              Value: 54
            – Type: issue
              Value: 2
          Titles:
            – TitleFull: Optica Applicata
              Type: main
ResultId 1