Revolution or risk?—Assessing the potential and challenges of GPT-4V in radiologic image interpretation.

Saved in:
Bibliographic Details
Title: Revolution or risk?—Assessing the potential and challenges of GPT-4V in radiologic image interpretation.
Authors: Huppertz, Marc Sebastian1 (AUTHOR) mhuppertz@ukaachen.de, Siepmann, Robert1 (AUTHOR), Topp, David1 (AUTHOR), Nikoubashman, Omid2 (AUTHOR), Yüksel, Can1 (AUTHOR), Kuhl, Christiane Katharina1 (AUTHOR), Truhn, Daniel1 (AUTHOR), Nebelung, Sven1 (AUTHOR)
Source: European Radiology. Mar2025, Vol. 35 Issue 3, p1111-1121. 11p.
Subjects: Generative pre-trained transformers, Language models, Magnetic resonance imaging, Medical personnel, Differential diagnosis
Abstract: Objectives: ChatGPT-4 Vision (GPT-4V) is a state-of-the-art multimodal large language model (LLM) that may be queried using images. We aimed to evaluate the tool's diagnostic performance when autonomously assessing clinical imaging studies. Materials and methods: A total of 206 imaging studies (i.e., radiography (n = 60), CT (n = 60), MRI (n = 60), and angiography (n = 26)) with unequivocal findings and established reference diagnoses from the radiologic practice of a large university hospital were accessed. Readings were performed uncontextualized, with only the image provided, and contextualized, with additional clinical and demographic information. Responses were assessed along multiple diagnostic dimensions and analyzed using appropriate statistical tests. Results: With its pronounced propensity to favor context over image information, the tool's diagnostic accuracy improved from 8.3% (uncontextualized) to 29.1% (contextualized, first diagnosis correct) and 63.6% (contextualized, correct diagnosis among differential diagnoses) (p ≤ 0.001, Cochran's Q test). Diagnostic accuracy declined by up to 30% when 20 images were re-read after 30 and 90 days and seemed unrelated to the tool's self-reported confidence (Spearman's ρ = 0.117 (p = 0.776)). While the described imaging findings matched the suggested diagnoses in 92.7%, indicating valid diagnostic reasoning, the tool fabricated 258 imaging findings in 412 responses and misidentified imaging modalities or anatomic regions in 65 images. Conclusion: GPT-4V, in its current form, cannot reliably interpret radiologic images. Its tendency to disregard the image, fabricate findings, and misidentify details, especially without clinical context, may misguide healthcare providers and put patients at risk. Key Points: QuestionCan Generative Pre-trained Transformer 4 Vision (GPT-4V) interpret radiologic images—with and without clinical context? FindingsGPT-4V performed poorly, demonstrating diagnostic accuracy rates of 8% (uncontextualized), 29% (contextualized, most likely diagnosis correct), and 64% (contextualized, correct diagnosis among differential diagnoses). Clinical relevanceThe utility of commercial multimodal large language models, such as GPT-4V, in radiologic practice is limited. Without clinical context, diagnostic errors and fabricated findings may compromise patient safety and misguide clinical decision-making. These models must be further refined to be beneficial. [ABSTRACT FROM AUTHOR]
Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
Description
Abstract:Objectives: ChatGPT-4 Vision (GPT-4V) is a state-of-the-art multimodal large language model (LLM) that may be queried using images. We aimed to evaluate the tool's diagnostic performance when autonomously assessing clinical imaging studies. Materials and methods: A total of 206 imaging studies (i.e., radiography (n = 60), CT (n = 60), MRI (n = 60), and angiography (n = 26)) with unequivocal findings and established reference diagnoses from the radiologic practice of a large university hospital were accessed. Readings were performed uncontextualized, with only the image provided, and contextualized, with additional clinical and demographic information. Responses were assessed along multiple diagnostic dimensions and analyzed using appropriate statistical tests. Results: With its pronounced propensity to favor context over image information, the tool's diagnostic accuracy improved from 8.3% (uncontextualized) to 29.1% (contextualized, first diagnosis correct) and 63.6% (contextualized, correct diagnosis among differential diagnoses) (p ≤ 0.001, Cochran's Q test). Diagnostic accuracy declined by up to 30% when 20 images were re-read after 30 and 90 days and seemed unrelated to the tool's self-reported confidence (Spearman's ρ = 0.117 (p = 0.776)). While the described imaging findings matched the suggested diagnoses in 92.7%, indicating valid diagnostic reasoning, the tool fabricated 258 imaging findings in 412 responses and misidentified imaging modalities or anatomic regions in 65 images. Conclusion: GPT-4V, in its current form, cannot reliably interpret radiologic images. Its tendency to disregard the image, fabricate findings, and misidentify details, especially without clinical context, may misguide healthcare providers and put patients at risk. Key Points: QuestionCan Generative Pre-trained Transformer 4 Vision (GPT-4V) interpret radiologic images—with and without clinical context? FindingsGPT-4V performed poorly, demonstrating diagnostic accuracy rates of 8% (uncontextualized), 29% (contextualized, most likely diagnosis correct), and 64% (contextualized, correct diagnosis among differential diagnoses). Clinical relevanceThe utility of commercial multimodal large language models, such as GPT-4V, in radiologic practice is limited. Without clinical context, diagnostic errors and fabricated findings may compromise patient safety and misguide clinical decision-making. These models must be further refined to be beneficial. [ABSTRACT FROM AUTHOR]
ISSN:09387994
DOI:10.1007/s00330-024-11115-6