Application of Fuzzy Controllers for Power Control of the VVER-1200 Nuclear Reactor.

Saved in:
Bibliographic Details
Title: Application of Fuzzy Controllers for Power Control of the VVER-1200 Nuclear Reactor.
Authors: Pravosud, S. S.1,2 (AUTHOR) ssepravosud@rosatom.ru, Maslakov, D. S.2 (AUTHOR), Yakubov, Ya. O.2 (AUTHOR)
Source: Physics of Atomic Nuclei. Dec2024, Vol. 87 Issue 10, p1430-1439. 10p.
Subjects: Automatic control systems, Control elements (Nuclear reactors), Nuclear reactor control, Neutron flux, Nuclear reactors
Abstract: This article deals with fuzzy and fuzzy PI controllers for the automatic power control system of a linearized mathematical model of the VVER-1200 nuclear reactor. The automatic power control system includes a mathematical model of a step-by-step electromagnetic drive (SED), a model of in-core and ex-core neutron flux sensors, and a refined mathematical model of the group 12 of control and protection system of control rods (CPS CR) obtained by approximating experimental data using the Levenberg–Marquardt algorithm for the nonlinear least squares problem. Based on the state space model, ten transfer function matrices of the nuclear reactor corresponding to a power range of from 10 to 100% of the nominal power were determined, and ten classical PI controllers were designed to ensure stability margins of at least 60° in phase and at least 10 decibels in amplitude for each power level of the plant. Simulation results show a significant advantage of the developed fuzzy controllers both in the steady-state power maintenance mode considering noise in the neutron flux sensor channel and in the load-following mode at different power levels. [ABSTRACT FROM AUTHOR]
Copyright of Physics of Atomic Nuclei is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
Description
Abstract:This article deals with fuzzy and fuzzy PI controllers for the automatic power control system of a linearized mathematical model of the VVER-1200 nuclear reactor. The automatic power control system includes a mathematical model of a step-by-step electromagnetic drive (SED), a model of in-core and ex-core neutron flux sensors, and a refined mathematical model of the group 12 of control and protection system of control rods (CPS CR) obtained by approximating experimental data using the Levenberg–Marquardt algorithm for the nonlinear least squares problem. Based on the state space model, ten transfer function matrices of the nuclear reactor corresponding to a power range of from 10 to 100% of the nominal power were determined, and ten classical PI controllers were designed to ensure stability margins of at least 60° in phase and at least 10 decibels in amplitude for each power level of the plant. Simulation results show a significant advantage of the developed fuzzy controllers both in the steady-state power maintenance mode considering noise in the neutron flux sensor channel and in the load-following mode at different power levels. [ABSTRACT FROM AUTHOR]
ISSN:10637788
DOI:10.1134/S1063778824100387