Simulation of accidental temperature and humidity in the pipeline rooms of the VVER NPP primary circuit.
Saved in:
| Title: | Simulation of accidental temperature and humidity in the pipeline rooms of the VVER NPP primary circuit. |
|---|---|
| Authors: | Matveev, E. L.1 (AUTHOR) matveevel@nikiet.ru, Cherkasova, M. S.1 (AUTHOR), Tutukin, A. V.1 (AUTHOR) |
| Source: | Atomic Energy. Sep2025, Vol. 136 Issue 5, p326-331. 6p. |
| Subjects: | Leak detection, Artificial intelligence, Image processing, Humidity, Coolants |
| Abstract: | The paper considers temperature and humidity simulation of the primary circuit pipeline rooms located at power units No. 3 and 4 of the Kola NPP upon the occurrence of equipment leakage. Simulation results were used to describe the dependence of the leakage on the temperature and relative humidity recorded by the sensors. Thus, advanced methods of automated coolant leak detection were developed; existing methods were adjusted. [ABSTRACT FROM AUTHOR] |
| Copyright of Atomic Energy is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Links: – Type: pdflink Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 183536902 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Simulation of accidental temperature and humidity in the pipeline rooms of the VVER NPP primary circuit. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Matveev%2C+E%2E+L%2E%22">Matveev, E. L.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> matveevel@nikiet.ru</i><br /><searchLink fieldCode="AR" term="%22Cherkasova%2C+M%2E+S%2E%22">Cherkasova, M. S.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Tutukin%2C+A%2E+V%2E%22">Tutukin, A. V.</searchLink><relatesTo>1</relatesTo> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Atomic+Energy%22">Atomic Energy</searchLink>. Sep2025, Vol. 136 Issue 5, p326-331. 6p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Leak+detection%22">Leak detection</searchLink><br /><searchLink fieldCode="DE" term="%22Artificial+intelligence%22">Artificial intelligence</searchLink><br /><searchLink fieldCode="DE" term="%22Image+processing%22">Image processing</searchLink><br /><searchLink fieldCode="DE" term="%22Humidity%22">Humidity</searchLink><br /><searchLink fieldCode="DE" term="%22Coolants%22">Coolants</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: The paper considers temperature and humidity simulation of the primary circuit pipeline rooms located at power units No. 3 and 4 of the Kola NPP upon the occurrence of equipment leakage. Simulation results were used to describe the dependence of the leakage on the temperature and relative humidity recorded by the sensors. Thus, advanced methods of automated coolant leak detection were developed; existing methods were adjusted. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Atomic Energy is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=183536902 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1007/s10512-024-01168-7 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 6 StartPage: 326 Subjects: – SubjectFull: Leak detection Type: general – SubjectFull: Artificial intelligence Type: general – SubjectFull: Image processing Type: general – SubjectFull: Humidity Type: general – SubjectFull: Coolants Type: general Titles: – TitleFull: Simulation of accidental temperature and humidity in the pipeline rooms of the VVER NPP primary circuit. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Matveev, E. L. – PersonEntity: Name: NameFull: Cherkasova, M. S. – PersonEntity: Name: NameFull: Tutukin, A. V. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 09 Text: Sep2025 Type: published Y: 2025 Identifiers: – Type: issn-print Value: 10634258 Numbering: – Type: volume Value: 136 – Type: issue Value: 5 Titles: – TitleFull: Atomic Energy Type: main |
| ResultId | 1 |