Real-time monitoring method for gadolinium concentration in a water Cherenkov detector: Real-time monitoring method for gadolinium concentration in a water Cherenkov detector: Y. Iwata et al.

Saved in:
Bibliographic Details
Title: Real-time monitoring method for gadolinium concentration in a water Cherenkov detector: Real-time monitoring method for gadolinium concentration in a water Cherenkov detector: Y. Iwata et al.
Authors: Iwata, Yoshihiro1 (AUTHOR) iwata.yoshihiro@jaea.go.jp, Sekiya, Hiroyuki2,3 (AUTHOR), Ito, Chikara4 (AUTHOR)
Source: Applied Physics A: Materials Science & Processing. Mar2025, Vol. 131 Issue 3, p1-8. 8p.
Subjects: Physical sciences, Cherenkov counters, Photomultipliers, Luminescence spectroscopy, Ion emission, Inductively coupled plasma atomic emission spectrometry, Laser-induced breakdown spectroscopy
Abstract: Time-resolved laser-induced luminescence spectroscopy is useful for real-time measurement of lanthanide ion concentrations in aqueous solution. Gadolinium ions (Gd 3 + ), in particular, have a long (∼ ms) emission lifetime, so that the ion emission can be easily distinguished from scattering of the excitation pulsed laser without the need for a monochromator. In this work, we have developed a real-time monitoring method for Gd concentration in water, aiming at application to the Super-Kamiokande (SK) water Cherenkov detector in which 0.03% Gd is currently dissolved in the form of sulfate for the observation of supernova relic neutrino events. The basic concept is to install a tube to run a portion of the water sample through a quartz cell (2 cm on each side), where a ns-pulsed laser at 266 nm is irradiated to excite Gd 3 + ions. The generated Gd 3 + ion emission at 312 nm is collimated by a lens, transmitted through a bandpass filter, and then detected by a photomultiplier tube placed about 10 cm away from the quartz cell. While lower Gd concentration and higher pulsed laser energy resulted in shorter Gd 3 + emission lifetime, good linearity was confirmed between Gd concentration and normalized peak emission voltage in the wide range of 1–1000 ppm (0.1%) Gd in ultrapure water. The detection limit, defined as three times the standard deviation of the background level, was determined to be ∼ 60 ppb for Gd sulfate in ultrapure water. This value is about two orders of magnitude better than the reported value using laser-induced breakdown spectroscopy, and is close to that using inductively coupled plasma optical emission spectrometry which requires sample introduction into the spectrometer. Sulfate ions in aqueous solution appear to have a smaller quenching effect than O–H vibrations of water molecules coordinated to the cation. By confirming a detection sensitivity below the ppm-level, this method could be effective for monitoring of drainage water from the SK detector tank as well. Our real-time monitoring method is expected to support the long-term operation of the SK-Gd project. [ABSTRACT FROM AUTHOR]
Copyright of Applied Physics A: Materials Science & Processing is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 183892127
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Real-time monitoring method for gadolinium concentration in a water Cherenkov detector: Real-time monitoring method for gadolinium concentration in a water Cherenkov detector: Y. Iwata et al.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Iwata%2C+Yoshihiro%22">Iwata, Yoshihiro</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> iwata.yoshihiro@jaea.go.jp</i><br /><searchLink fieldCode="AR" term="%22Sekiya%2C+Hiroyuki%22">Sekiya, Hiroyuki</searchLink><relatesTo>2,3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Ito%2C+Chikara%22">Ito, Chikara</searchLink><relatesTo>4</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Applied+Physics+A%3A+Materials+Science+%26+Processing%22">Applied Physics A: Materials Science & Processing</searchLink>. Mar2025, Vol. 131 Issue 3, p1-8. 8p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Physical+sciences%22">Physical sciences</searchLink><br /><searchLink fieldCode="DE" term="%22Cherenkov+counters%22">Cherenkov counters</searchLink><br /><searchLink fieldCode="DE" term="%22Photomultipliers%22">Photomultipliers</searchLink><br /><searchLink fieldCode="DE" term="%22Luminescence+spectroscopy%22">Luminescence spectroscopy</searchLink><br /><searchLink fieldCode="DE" term="%22Ion+emission%22">Ion emission</searchLink><br /><searchLink fieldCode="DE" term="%22Inductively+coupled+plasma+atomic+emission+spectrometry%22">Inductively coupled plasma atomic emission spectrometry</searchLink><br /><searchLink fieldCode="DE" term="%22Laser-induced+breakdown+spectroscopy%22">Laser-induced breakdown spectroscopy</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Time-resolved laser-induced luminescence spectroscopy is useful for real-time measurement of lanthanide ion concentrations in aqueous solution. Gadolinium ions (Gd 3 + ), in particular, have a long (∼ ms) emission lifetime, so that the ion emission can be easily distinguished from scattering of the excitation pulsed laser without the need for a monochromator. In this work, we have developed a real-time monitoring method for Gd concentration in water, aiming at application to the Super-Kamiokande (SK) water Cherenkov detector in which 0.03% Gd is currently dissolved in the form of sulfate for the observation of supernova relic neutrino events. The basic concept is to install a tube to run a portion of the water sample through a quartz cell (2 cm on each side), where a ns-pulsed laser at 266 nm is irradiated to excite Gd 3 + ions. The generated Gd 3 + ion emission at 312 nm is collimated by a lens, transmitted through a bandpass filter, and then detected by a photomultiplier tube placed about 10 cm away from the quartz cell. While lower Gd concentration and higher pulsed laser energy resulted in shorter Gd 3 + emission lifetime, good linearity was confirmed between Gd concentration and normalized peak emission voltage in the wide range of 1–1000 ppm (0.1%) Gd in ultrapure water. The detection limit, defined as three times the standard deviation of the background level, was determined to be ∼ 60 ppb for Gd sulfate in ultrapure water. This value is about two orders of magnitude better than the reported value using laser-induced breakdown spectroscopy, and is close to that using inductively coupled plasma optical emission spectrometry which requires sample introduction into the spectrometer. Sulfate ions in aqueous solution appear to have a smaller quenching effect than O–H vibrations of water molecules coordinated to the cation. By confirming a detection sensitivity below the ppm-level, this method could be effective for monitoring of drainage water from the SK detector tank as well. Our real-time monitoring method is expected to support the long-term operation of the SK-Gd project. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Applied Physics A: Materials Science & Processing is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=183892127
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s00339-025-08283-7
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 8
        StartPage: 1
    Subjects:
      – SubjectFull: Physical sciences
        Type: general
      – SubjectFull: Cherenkov counters
        Type: general
      – SubjectFull: Photomultipliers
        Type: general
      – SubjectFull: Luminescence spectroscopy
        Type: general
      – SubjectFull: Ion emission
        Type: general
      – SubjectFull: Inductively coupled plasma atomic emission spectrometry
        Type: general
      – SubjectFull: Laser-induced breakdown spectroscopy
        Type: general
    Titles:
      – TitleFull: Real-time monitoring method for gadolinium concentration in a water Cherenkov detector: Real-time monitoring method for gadolinium concentration in a water Cherenkov detector: Y. Iwata et al.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Iwata, Yoshihiro
      – PersonEntity:
          Name:
            NameFull: Sekiya, Hiroyuki
      – PersonEntity:
          Name:
            NameFull: Ito, Chikara
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 03
              Text: Mar2025
              Type: published
              Y: 2025
          Identifiers:
            – Type: issn-print
              Value: 09478396
          Numbering:
            – Type: volume
              Value: 131
            – Type: issue
              Value: 3
          Titles:
            – TitleFull: Applied Physics A: Materials Science & Processing
              Type: main
ResultId 1