RapidBrachyIVBT: A dosimetry software for patient‐specific intravascular brachytherapy dose calculations on optical coherence tomography images.

Saved in:
Bibliographic Details
Title: RapidBrachyIVBT: A dosimetry software for patient‐specific intravascular brachytherapy dose calculations on optical coherence tomography images.
Authors: Rahbaran, Maryam1,2 (AUTHOR) maryam.rahbaran@mail.mcgill.ca, Kalinowski, Jonathan1,2 (AUTHOR), DeCunha, Joseph M.3,4 (AUTHOR), Croce, Kevin J.5 (AUTHOR), Bergmark, Brian A.5 (AUTHOR), Tsui, James M. G.6 (AUTHOR), Devlin, Phillip M.7 (AUTHOR), Enger, Shirin A.1,2 (AUTHOR)
Source: Medical Physics. Feb2025, Vol. 52 Issue 2, p1256-1267. 12p.
Subjects: Coronary artery disease, Optical coherence tomography, Medical dosimetry, Radioisotope brachytherapy, Interstitial brachytherapy, Drug-eluting stents, Monte Carlo method, Hyperplasia
Abstract: Background: Coronary artery disease is the most common form of cardiovascular disease. It is caused by excess plaque along the arterial wall, blocking blood flow to the heart (stenosis). A percutaneous coronary intervention widens the arterial wall with the inflation of a balloon inside the lesion area and leaves behind a metal stent to prevent re‐narrowing of the artery (restenosis). However, in‐stent restenosis may occur due to damage to the arterial wall tissue, triggering neointimal hyperplasia, producing fibrotic and calcified plaques and narrowing the artery again. Drug‐eluting stents, which slowly release medication to inhibit neointimal hyperplasia, are used to prevent in‐stent restenosis but fail up to 20% of cases. Coronary intravascular brachytherapy (IVBT), which uses β$\beta$‐emitting radionuclides to prevent in‐stent restenosis, is used in these failed cases to prevent in‐stent restenosis. However, current clinical dosimetry for IVBT is water‐based, and heterogeneities such as the guidewire of the IVBT device, fibrotic and calcified plaques and stents are not considered. Purpose: This study aimed to develop a Monte Carlo‐based dose calculation software, accounting for patient‐specific geometry from Optical Coherence Tomography (OCT) images. Methods: RapidBrachyIVBT, a Monte Carlo dose calculation software based on the Geant4 toolkit v. 10.02.p02, was developed and integrated into RapidBrachyMCTPS, a treatment planning system for brachytherapy applications. The only commercially available IVBT delivery system, the Novoste Beta‐Cath 3.5F, with a 90Sr90Y$^{90}{\rm Sr}^{90}{\rm Y}$ source train, was modeled with 30, 40, and 60 mm source train lengths. The software was validated with published TG‐149 parameters compared to Monte Carlo simulations in water. The dose calculation engine was tested with OCT images from a patient undergoing coronary IVBT for recurrent in‐stent restenosis at Brigham and Women's Hospital in Boston, Massachusetts. Considering the heterogeneities, the images were segmented and used to calculate the absorbed dose to water and the absorbed dose to medium. The prescribed dose was normalized to 23 Gy at 2.0 mm from the source center, which is the target volume in IVBT. Results: The dose rate values in water obtained using RapidBrachyIVBT aligned with TG‐149 consensus values, showing agreement within a range of 0.03% to 1.7%. Considering the heterogeneities present in the patient's OCT images, the absorbed dose in the entire artery segment was up to 77.5% lower, while within the target volume, it was up to 56.6% lower, compared to the dose calculated in a homogeneous water phantom. Conclusion: RapidBrachyIVBT, a Monte Carlo dose calculation software for IVBT, was developed and successfully integrated into RapidBrachyMCTPS, a treatment planning system for brachytherapy applications, where accurate attenuation of the absorbed dose by heterogeneities is considered. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 183916611
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: RapidBrachyIVBT: A dosimetry software for patient‐specific intravascular brachytherapy dose calculations on optical coherence tomography images.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Rahbaran%2C+Maryam%22">Rahbaran, Maryam</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<i> maryam.rahbaran@mail.mcgill.ca</i><br /><searchLink fieldCode="AR" term="%22Kalinowski%2C+Jonathan%22">Kalinowski, Jonathan</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22DeCunha%2C+Joseph+M%2E%22">DeCunha, Joseph M.</searchLink><relatesTo>3,4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Croce%2C+Kevin+J%2E%22">Croce, Kevin J.</searchLink><relatesTo>5</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Bergmark%2C+Brian+A%2E%22">Bergmark, Brian A.</searchLink><relatesTo>5</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Tsui%2C+James+M%2E+G%2E%22">Tsui, James M. G.</searchLink><relatesTo>6</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Devlin%2C+Phillip+M%2E%22">Devlin, Phillip M.</searchLink><relatesTo>7</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Enger%2C+Shirin+A%2E%22">Enger, Shirin A.</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Feb2025, Vol. 52 Issue 2, p1256-1267. 12p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Coronary+artery+disease%22">Coronary artery disease</searchLink><br /><searchLink fieldCode="DE" term="%22Optical+coherence+tomography%22">Optical coherence tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+dosimetry%22">Medical dosimetry</searchLink><br /><searchLink fieldCode="DE" term="%22Radioisotope+brachytherapy%22">Radioisotope brachytherapy</searchLink><br /><searchLink fieldCode="DE" term="%22Interstitial+brachytherapy%22">Interstitial brachytherapy</searchLink><br /><searchLink fieldCode="DE" term="%22Drug-eluting+stents%22">Drug-eluting stents</searchLink><br /><searchLink fieldCode="DE" term="%22Monte+Carlo+method%22">Monte Carlo method</searchLink><br /><searchLink fieldCode="DE" term="%22Hyperplasia%22">Hyperplasia</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Background: Coronary artery disease is the most common form of cardiovascular disease. It is caused by excess plaque along the arterial wall, blocking blood flow to the heart (stenosis). A percutaneous coronary intervention widens the arterial wall with the inflation of a balloon inside the lesion area and leaves behind a metal stent to prevent re‐narrowing of the artery (restenosis). However, in‐stent restenosis may occur due to damage to the arterial wall tissue, triggering neointimal hyperplasia, producing fibrotic and calcified plaques and narrowing the artery again. Drug‐eluting stents, which slowly release medication to inhibit neointimal hyperplasia, are used to prevent in‐stent restenosis but fail up to 20% of cases. Coronary intravascular brachytherapy (IVBT), which uses β$\beta$‐emitting radionuclides to prevent in‐stent restenosis, is used in these failed cases to prevent in‐stent restenosis. However, current clinical dosimetry for IVBT is water‐based, and heterogeneities such as the guidewire of the IVBT device, fibrotic and calcified plaques and stents are not considered. Purpose: This study aimed to develop a Monte Carlo‐based dose calculation software, accounting for patient‐specific geometry from Optical Coherence Tomography (OCT) images. Methods: RapidBrachyIVBT, a Monte Carlo dose calculation software based on the Geant4 toolkit v. 10.02.p02, was developed and integrated into RapidBrachyMCTPS, a treatment planning system for brachytherapy applications. The only commercially available IVBT delivery system, the Novoste Beta‐Cath 3.5F, with a 90Sr90Y$^{90}{\rm Sr}^{90}{\rm Y}$ source train, was modeled with 30, 40, and 60 mm source train lengths. The software was validated with published TG‐149 parameters compared to Monte Carlo simulations in water. The dose calculation engine was tested with OCT images from a patient undergoing coronary IVBT for recurrent in‐stent restenosis at Brigham and Women's Hospital in Boston, Massachusetts. Considering the heterogeneities, the images were segmented and used to calculate the absorbed dose to water and the absorbed dose to medium. The prescribed dose was normalized to 23 Gy at 2.0 mm from the source center, which is the target volume in IVBT. Results: The dose rate values in water obtained using RapidBrachyIVBT aligned with TG‐149 consensus values, showing agreement within a range of 0.03% to 1.7%. Considering the heterogeneities present in the patient's OCT images, the absorbed dose in the entire artery segment was up to 77.5% lower, while within the target volume, it was up to 56.6% lower, compared to the dose calculated in a homogeneous water phantom. Conclusion: RapidBrachyIVBT, a Monte Carlo dose calculation software for IVBT, was developed and successfully integrated into RapidBrachyMCTPS, a treatment planning system for brachytherapy applications, where accurate attenuation of the absorbed dose by heterogeneities is considered. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=183916611
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mp.17525
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 12
        StartPage: 1256
    Subjects:
      – SubjectFull: Coronary artery disease
        Type: general
      – SubjectFull: Optical coherence tomography
        Type: general
      – SubjectFull: Medical dosimetry
        Type: general
      – SubjectFull: Radioisotope brachytherapy
        Type: general
      – SubjectFull: Interstitial brachytherapy
        Type: general
      – SubjectFull: Drug-eluting stents
        Type: general
      – SubjectFull: Monte Carlo method
        Type: general
      – SubjectFull: Hyperplasia
        Type: general
    Titles:
      – TitleFull: RapidBrachyIVBT: A dosimetry software for patient‐specific intravascular brachytherapy dose calculations on optical coherence tomography images.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Rahbaran, Maryam
      – PersonEntity:
          Name:
            NameFull: Kalinowski, Jonathan
      – PersonEntity:
          Name:
            NameFull: DeCunha, Joseph M.
      – PersonEntity:
          Name:
            NameFull: Croce, Kevin J.
      – PersonEntity:
          Name:
            NameFull: Bergmark, Brian A.
      – PersonEntity:
          Name:
            NameFull: Tsui, James M. G.
      – PersonEntity:
          Name:
            NameFull: Devlin, Phillip M.
      – PersonEntity:
          Name:
            NameFull: Enger, Shirin A.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 02
              Text: Feb2025
              Type: published
              Y: 2025
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 52
            – Type: issue
              Value: 2
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1