Enhanced Voltage Sensorless Control for a PWM Converter with DSOGI-FLL Under Grid Disturbances.
Saved in:
| Title: | Enhanced Voltage Sensorless Control for a PWM Converter with DSOGI-FLL Under Grid Disturbances. |
|---|---|
| Authors: | Kang, Seung-Pyo1 (AUTHOR), Kim, Dong-Youn2 (AUTHOR), Kim, Jang-Mok3 (AUTHOR) jmok@pusan.ac.kr |
| Source: | Energies (19961073). May2025, Vol. 18 Issue 9, p2199. 27p. |
| Subjects: | Signal generators, Ideal sources (Electric circuits), Voltage control, Voltage, Detectors |
| Abstract: | This paper presents Enhanced Voltage Sensorless Control for PWM converter with DSOGI-FLL under grid disturbances. Even without grid voltage sensors, the proposed method accurately estimates the grid angle and voltage, which are necessary for power transfer between the DC link of the PWM converter and the grid. The estimated grid voltage obtained through observer design is separated into positive and negative sequence components, and the grid frequency is estimated using the Dual Second-Order Generalized Integrator Quadrature Signal Generator (DSOGI-QSG) and Dual Second-Order Generalized Integrator Frequency-Locked Loop (DSOGI-FLL). The estimated positive and negative sequence voltages were effectively controlled using a dual current controller. The method operates effectively under normal, balanced AC source conditions and in various grid fault scenarios, including unbalanced voltage, harmonic distortion, voltage sag, and frequency step changes. The validity of the proposed method was evaluated through experimental results by using a grid simulator to implement the fault condition. [ABSTRACT FROM AUTHOR] |
| Copyright of Energies (19961073) is the property of MDPI and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| Abstract: | This paper presents Enhanced Voltage Sensorless Control for PWM converter with DSOGI-FLL under grid disturbances. Even without grid voltage sensors, the proposed method accurately estimates the grid angle and voltage, which are necessary for power transfer between the DC link of the PWM converter and the grid. The estimated grid voltage obtained through observer design is separated into positive and negative sequence components, and the grid frequency is estimated using the Dual Second-Order Generalized Integrator Quadrature Signal Generator (DSOGI-QSG) and Dual Second-Order Generalized Integrator Frequency-Locked Loop (DSOGI-FLL). The estimated positive and negative sequence voltages were effectively controlled using a dual current controller. The method operates effectively under normal, balanced AC source conditions and in various grid fault scenarios, including unbalanced voltage, harmonic distortion, voltage sag, and frequency step changes. The validity of the proposed method was evaluated through experimental results by using a grid simulator to implement the fault condition. [ABSTRACT FROM AUTHOR] |
|---|---|
| ISSN: | 19961073 |
| DOI: | 10.3390/en18092199 |