Dual-Contrast Agent with Nanoparticle and Molecular Components in Photon-Counting Computed Tomography: Assessing Articular Cartilage Health.

Saved in:
Bibliographic Details
Title: Dual-Contrast Agent with Nanoparticle and Molecular Components in Photon-Counting Computed Tomography: Assessing Articular Cartilage Health.
Authors: Paakkari, Petri1,2 (AUTHOR) petri.paakkari@uef.fi, Inkinen, Satu I.3 (AUTHOR), Jäntti, Jiri1,2 (AUTHOR), Tuppurainen, Juuso1,2 (AUTHOR), Fugazzola, Maria C.4 (AUTHOR), Joenathan, Anisha5 (AUTHOR), Ylisiurua, Sampo6,7 (AUTHOR), Nieminen, Miika T.7 (AUTHOR), Kröger, Heikki8,9 (AUTHOR), Mikkonen, Santtu1,10 (AUTHOR), van Weeren, René4 (AUTHOR), Snyder, Brian D.11 (AUTHOR), Töyräs, Juha1,12,13 (AUTHOR), Honkanen, Miitu K. M.2 (AUTHOR), Matikka, Hanna2 (AUTHOR), Grinstaff, Mark W.5 (AUTHOR), Honkanen, Juuso T. J.14 (AUTHOR), Mäkelä, Janne T. A.1,2 (AUTHOR)
Source: Annals of Biomedical Engineering. Jun2025, Vol. 53 Issue 6, p1423-1438. 16p.
Subjects: Dual energy CT (Tomography), Articular cartilage, Contrast media, Biomedical engineering, Medical sciences
Abstract: Purpose: Photon-counting detectors (PCDs) are cutting-edge technology that enable spectral computed tomography (CT) imaging with a single scan. Spectral imaging is particularly effective in contrast-enhanced CT (CECT) imaging, especially when multiple contrast agents are utilized, as materials are distinguishable based on their unique X-ray absorption. One application of CECT is joint imaging, where it assesses the structure and composition of articular cartilage soft tissue. This evaluates articular cartilage and reveals compositional changes associated with early-stage osteoarthritis (OA) using a photon-counting detector CT (PCD-CT) technique combined with a dual-contrast agent method. Methods: A dual-contrast agent combination was used, consisting of proteoglycan-binding cationic tantalum oxide nanoparticles, developed in our lab, and a commercial non-ionic iodinated iodixanol agent. Ex vivo equine stifle joint cartilage samples (N = 30) were immersed in the contrast agent bath for 96 hours and imaged at multiple timepoints for analysis of proteoglycan, collagen, and water contents as well as collagen orientation, histological scoring, and biomechanical parameters. Results: By analyzing contrast agent concentrations, the technique provided a simultaneous assessment of the solid constituents and function of cartilage. Contrast agent diffusion depended on contrast agent composition and was significantly different between healthy and early-stage OA groups within 12 hours. Conclusion: The present study shows the promising utility of the dual-contrast PCD-CT technique for articular cartilage assessment and early-stage OA detection. [ABSTRACT FROM AUTHOR]
Copyright of Annals of Biomedical Engineering is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 185134755
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Dual-Contrast Agent with Nanoparticle and Molecular Components in Photon-Counting Computed Tomography: Assessing Articular Cartilage Health.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Paakkari%2C+Petri%22">Paakkari, Petri</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<i> petri.paakkari@uef.fi</i><br /><searchLink fieldCode="AR" term="%22Inkinen%2C+Satu+I%2E%22">Inkinen, Satu I.</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Jäntti%2C+Jiri%22">Jäntti, Jiri</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Tuppurainen%2C+Juuso%22">Tuppurainen, Juuso</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Fugazzola%2C+Maria+C%2E%22">Fugazzola, Maria C.</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Joenathan%2C+Anisha%22">Joenathan, Anisha</searchLink><relatesTo>5</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Ylisiurua%2C+Sampo%22">Ylisiurua, Sampo</searchLink><relatesTo>6,7</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Nieminen%2C+Miika+T%2E%22">Nieminen, Miika T.</searchLink><relatesTo>7</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kröger%2C+Heikki%22">Kröger, Heikki</searchLink><relatesTo>8,9</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Mikkonen%2C+Santtu%22">Mikkonen, Santtu</searchLink><relatesTo>1,10</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22van+Weeren%2C+René%22">van Weeren, René</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Snyder%2C+Brian+D%2E%22">Snyder, Brian D.</searchLink><relatesTo>11</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Töyräs%2C+Juha%22">Töyräs, Juha</searchLink><relatesTo>1,12,13</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Honkanen%2C+Miitu+K%2E+M%2E%22">Honkanen, Miitu K. M.</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Matikka%2C+Hanna%22">Matikka, Hanna</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Grinstaff%2C+Mark+W%2E%22">Grinstaff, Mark W.</searchLink><relatesTo>5</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Honkanen%2C+Juuso+T%2E+J%2E%22">Honkanen, Juuso T. J.</searchLink><relatesTo>14</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Mäkelä%2C+Janne+T%2E+A%2E%22">Mäkelä, Janne T. A.</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Annals+of+Biomedical+Engineering%22">Annals of Biomedical Engineering</searchLink>. Jun2025, Vol. 53 Issue 6, p1423-1438. 16p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Dual+energy+CT+%28Tomography%29%22">Dual energy CT (Tomography)</searchLink><br /><searchLink fieldCode="DE" term="%22Articular+cartilage%22">Articular cartilage</searchLink><br /><searchLink fieldCode="DE" term="%22Contrast+media%22">Contrast media</searchLink><br /><searchLink fieldCode="DE" term="%22Biomedical+engineering%22">Biomedical engineering</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+sciences%22">Medical sciences</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose: Photon-counting detectors (PCDs) are cutting-edge technology that enable spectral computed tomography (CT) imaging with a single scan. Spectral imaging is particularly effective in contrast-enhanced CT (CECT) imaging, especially when multiple contrast agents are utilized, as materials are distinguishable based on their unique X-ray absorption. One application of CECT is joint imaging, where it assesses the structure and composition of articular cartilage soft tissue. This evaluates articular cartilage and reveals compositional changes associated with early-stage osteoarthritis (OA) using a photon-counting detector CT (PCD-CT) technique combined with a dual-contrast agent method. Methods: A dual-contrast agent combination was used, consisting of proteoglycan-binding cationic tantalum oxide nanoparticles, developed in our lab, and a commercial non-ionic iodinated iodixanol agent. Ex vivo equine stifle joint cartilage samples (N = 30) were immersed in the contrast agent bath for 96 hours and imaged at multiple timepoints for analysis of proteoglycan, collagen, and water contents as well as collagen orientation, histological scoring, and biomechanical parameters. Results: By analyzing contrast agent concentrations, the technique provided a simultaneous assessment of the solid constituents and function of cartilage. Contrast agent diffusion depended on contrast agent composition and was significantly different between healthy and early-stage OA groups within 12 hours. Conclusion: The present study shows the promising utility of the dual-contrast PCD-CT technique for articular cartilage assessment and early-stage OA detection. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Annals of Biomedical Engineering is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=185134755
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s10439-025-03715-0
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 16
        StartPage: 1423
    Subjects:
      – SubjectFull: Dual energy CT (Tomography)
        Type: general
      – SubjectFull: Articular cartilage
        Type: general
      – SubjectFull: Contrast media
        Type: general
      – SubjectFull: Biomedical engineering
        Type: general
      – SubjectFull: Medical sciences
        Type: general
    Titles:
      – TitleFull: Dual-Contrast Agent with Nanoparticle and Molecular Components in Photon-Counting Computed Tomography: Assessing Articular Cartilage Health.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Paakkari, Petri
      – PersonEntity:
          Name:
            NameFull: Inkinen, Satu I.
      – PersonEntity:
          Name:
            NameFull: Jäntti, Jiri
      – PersonEntity:
          Name:
            NameFull: Tuppurainen, Juuso
      – PersonEntity:
          Name:
            NameFull: Fugazzola, Maria C.
      – PersonEntity:
          Name:
            NameFull: Joenathan, Anisha
      – PersonEntity:
          Name:
            NameFull: Ylisiurua, Sampo
      – PersonEntity:
          Name:
            NameFull: Nieminen, Miika T.
      – PersonEntity:
          Name:
            NameFull: Kröger, Heikki
      – PersonEntity:
          Name:
            NameFull: Mikkonen, Santtu
      – PersonEntity:
          Name:
            NameFull: van Weeren, René
      – PersonEntity:
          Name:
            NameFull: Snyder, Brian D.
      – PersonEntity:
          Name:
            NameFull: Töyräs, Juha
      – PersonEntity:
          Name:
            NameFull: Honkanen, Miitu K. M.
      – PersonEntity:
          Name:
            NameFull: Matikka, Hanna
      – PersonEntity:
          Name:
            NameFull: Grinstaff, Mark W.
      – PersonEntity:
          Name:
            NameFull: Honkanen, Juuso T. J.
      – PersonEntity:
          Name:
            NameFull: Mäkelä, Janne T. A.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 06
              Text: Jun2025
              Type: published
              Y: 2025
          Identifiers:
            – Type: issn-print
              Value: 00906964
          Numbering:
            – Type: volume
              Value: 53
            – Type: issue
              Value: 6
          Titles:
            – TitleFull: Annals of Biomedical Engineering
              Type: main
ResultId 1