Vascular Flow Phantom of A Cohort-Based Averaged Abdominal Aortic Aneurysm: Design, Fabrication and Characterization.
Saved in:
| Title: | Vascular Flow Phantom of A Cohort-Based Averaged Abdominal Aortic Aneurysm: Design, Fabrication and Characterization. |
|---|---|
| Authors: | Mirgolbabaee, H.1,2 (AUTHOR), Nagel, J. R.1,2 (AUTHOR) j.r.nagel@utwente.nl, Plomp, J.1,2 (AUTHOR), Ghanbarzadeh-Dagheyan, A.3 (AUTHOR), Simmering, J. A.1,4 (AUTHOR), Versluis, M.2 (AUTHOR), Reijnen, M. M. P. J.1,5 (AUTHOR), Groot Jebbink, E.1,5 (AUTHOR) e.grootjebbink@utwente.nl |
| Source: | Annals of Biomedical Engineering. Jun2025, Vol. 53 Issue 6, p1439-1452. 14p. |
| Subjects: | Particle image velocimetry, Abdominal aortic aneurysms, Flow sensors, Computed tomography, Ultrasonic imaging |
| Abstract: | Purpose: Vascular flow phantoms are an invaluable tool for in vitro and in silico studies, but their design and fabrication processes are often not reported. In this study, a framework is introduced to design and fabricate 3D printable high-fidelity cohort-based averaged abdominal aortic aneurysm (AAA) phantoms. Methods: AAA geometries of 50 patients were segmented from preoperative computed tomography angiography scans. The segmented geometries and center lumen lines (CLL) were used in an in-house developed algorithm to average the CLL coordinates and corresponding diameters over the entire cohort. The reconstructed averaged anatomy was 3D printed as a thin-walled flow phantom with Formlabs Flexible 80A resin. The acoustic properties of the resin were characterized and the feasibility of flow field quantification inside the phantom with ultrasound particle imaging velocimetry (echoPIV) was investigated. Results: Comparison between patient-specific models generated by our method and their corresponding reference segmentations, for ten patients, showed a mean Sørensen–Dice similarity coefficient of 0.916 ± 0.21 and the largest distances (5-10% of the lumen diameter) were found at the aneurysmal sac. The Flexible 80A resin had an average speed of sound of 1785 m/s, attenuation of 7.8 dB/mm and density of 1130 kg/m3. Volumetric flow profiles obtained with echoPIV in the suprarenal artery (i.e. phantom inlet) matched the flow sensor data. Conclusion: The reported framework was used to make an averaged, cohort-based AAA model, which showed a good match with its reference model. A 3D printed, thin-walled phantom was made based on this model and the feasibility of flow field quantification inside the phantom was shown. [ABSTRACT FROM AUTHOR] |
| Copyright of Annals of Biomedical Engineering is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 185134756 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Vascular Flow Phantom of A Cohort-Based Averaged Abdominal Aortic Aneurysm: Design, Fabrication and Characterization. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Mirgolbabaee%2C+H%2E%22">Mirgolbabaee, H.</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Nagel%2C+J%2E+R%2E%22">Nagel, J. R.</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<i> j.r.nagel@utwente.nl</i><br /><searchLink fieldCode="AR" term="%22Plomp%2C+J%2E%22">Plomp, J.</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Ghanbarzadeh-Dagheyan%2C+A%2E%22">Ghanbarzadeh-Dagheyan, A.</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Simmering%2C+J%2E+A%2E%22">Simmering, J. A.</searchLink><relatesTo>1,4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Versluis%2C+M%2E%22">Versluis, M.</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Reijnen%2C+M%2E+M%2E+P%2E+J%2E%22">Reijnen, M. M. P. J.</searchLink><relatesTo>1,5</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Groot+Jebbink%2C+E%2E%22">Groot Jebbink, E.</searchLink><relatesTo>1,5</relatesTo> (AUTHOR)<i> e.grootjebbink@utwente.nl</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Annals+of+Biomedical+Engineering%22">Annals of Biomedical Engineering</searchLink>. Jun2025, Vol. 53 Issue 6, p1439-1452. 14p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Particle+image+velocimetry%22">Particle image velocimetry</searchLink><br /><searchLink fieldCode="DE" term="%22Abdominal+aortic+aneurysms%22">Abdominal aortic aneurysms</searchLink><br /><searchLink fieldCode="DE" term="%22Flow+sensors%22">Flow sensors</searchLink><br /><searchLink fieldCode="DE" term="%22Computed+tomography%22">Computed tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Ultrasonic+imaging%22">Ultrasonic imaging</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Purpose: Vascular flow phantoms are an invaluable tool for in vitro and in silico studies, but their design and fabrication processes are often not reported. In this study, a framework is introduced to design and fabricate 3D printable high-fidelity cohort-based averaged abdominal aortic aneurysm (AAA) phantoms. Methods: AAA geometries of 50 patients were segmented from preoperative computed tomography angiography scans. The segmented geometries and center lumen lines (CLL) were used in an in-house developed algorithm to average the CLL coordinates and corresponding diameters over the entire cohort. The reconstructed averaged anatomy was 3D printed as a thin-walled flow phantom with Formlabs Flexible 80A resin. The acoustic properties of the resin were characterized and the feasibility of flow field quantification inside the phantom with ultrasound particle imaging velocimetry (echoPIV) was investigated. Results: Comparison between patient-specific models generated by our method and their corresponding reference segmentations, for ten patients, showed a mean Sørensen–Dice similarity coefficient of 0.916 ± 0.21 and the largest distances (5-10% of the lumen diameter) were found at the aneurysmal sac. The Flexible 80A resin had an average speed of sound of 1785 m/s, attenuation of 7.8 dB/mm and density of 1130 kg/m3. Volumetric flow profiles obtained with echoPIV in the suprarenal artery (i.e. phantom inlet) matched the flow sensor data. Conclusion: The reported framework was used to make an averaged, cohort-based AAA model, which showed a good match with its reference model. A 3D printed, thin-walled phantom was made based on this model and the feasibility of flow field quantification inside the phantom was shown. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Annals of Biomedical Engineering is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=185134756 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1007/s10439-025-03717-y Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 14 StartPage: 1439 Subjects: – SubjectFull: Particle image velocimetry Type: general – SubjectFull: Abdominal aortic aneurysms Type: general – SubjectFull: Flow sensors Type: general – SubjectFull: Computed tomography Type: general – SubjectFull: Ultrasonic imaging Type: general Titles: – TitleFull: Vascular Flow Phantom of A Cohort-Based Averaged Abdominal Aortic Aneurysm: Design, Fabrication and Characterization. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Mirgolbabaee, H. – PersonEntity: Name: NameFull: Nagel, J. R. – PersonEntity: Name: NameFull: Plomp, J. – PersonEntity: Name: NameFull: Ghanbarzadeh-Dagheyan, A. – PersonEntity: Name: NameFull: Simmering, J. A. – PersonEntity: Name: NameFull: Versluis, M. – PersonEntity: Name: NameFull: Reijnen, M. M. P. J. – PersonEntity: Name: NameFull: Groot Jebbink, E. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 06 Text: Jun2025 Type: published Y: 2025 Identifiers: – Type: issn-print Value: 00906964 Numbering: – Type: volume Value: 53 – Type: issue Value: 6 Titles: – TitleFull: Annals of Biomedical Engineering Type: main |
| ResultId | 1 |