Hyperpolarized 129Xe diffusion‐weighted MRI of the lung with 3D golden‐angle radial sampling and keyhole reconstruction.
Saved in:
| Title: | Hyperpolarized 129Xe diffusion‐weighted MRI of the lung with 3D golden‐angle radial sampling and keyhole reconstruction. |
|---|---|
| Authors: | Shen, Luyang1 (AUTHOR), Li, Haidong1,2 (AUTHOR), Fang, Yuan1 (AUTHOR), Luo, Ming1 (AUTHOR), Li, Yecheng1,2 (AUTHOR), Zhou, Qian1 (AUTHOR), Rao, Qiuchen1 (AUTHOR), Zhang, Ming1,2 (AUTHOR), Zhao, Xiuchao1,2 (AUTHOR), Shi, Lei1,2 (AUTHOR), Han, Yeqing1,2 (AUTHOR), Guo, Fumin1 (AUTHOR), Zhou, Xin1,2,3 (AUTHOR) xinzhou@wipm.ac.cn |
| Source: | Medical Physics. Jun2025, Vol. 52 Issue 6, p4068-4078. 11p. |
| Subjects: | Diffusion magnetic resonance imaging, Xenon, Compressed sensing, Lungs, Pulmonary function tests |
| Abstract: | Background: Hyperpolarized (HP) 129Xe multiple b‐values diffusion‐weighted imaging (DWI) facilitates the assessment of pulmonary morphology. However, conventional DWI method, such as 2D GRE DWI, is limited in its application due to the long acquisition time and relatively thick slice. Purpose: To develop a method combining 3D golden‐angle radial sampling with keyhole reconstruction (GRSK) for accelerating 129Xe multiple b‐values DWI and obtaining thinner slice. Methods: For 3D GRSK DWI, 3D kooshball golden‐angle radial sampling was used for image acquisition, with each spoke assigned to 1 of 4 b‐values, and keyhole method was applied for reconstructing DW images under different b‐values. 2D fully sampled GRE DWI and 3D GRSK DWI were obtained in five healthy young volunteers (HYV; 25 [24–26] years). Lung morphological parameter maps, including mean linear intercept (Lm) and surface‐to‐volume ratio (SVR), were generated using a cylinder model (CM) from the four b‐values DW images, and apparent diffusion coefficient (ADC) maps were derived through mono‐exponential fitting. Spearman correlation and Bland‐Altman analysis were performed to compare Lm, SVR and ADC from 2D GRE and 3D GRSK DWI. In addition, 3D GRSK DWI was applied in five emphysema patients (66 [60–69] years) and five age‐matched healthy controls (AMC; 59 [54–68] years), and Lm, SVR and ADC maps were also derived. Wilcoxon rank‐sum test was utilized to contrast Lm, SVR and ADC from patients with those from AMC. Results: DW images with an isotropic resolution (5 mm) were obtained with 3D GRSK DWI within 11.4 s. In comparison, 2D GRE DWI acquired four slices with 30 mm thickness in 15.9 s. For Lm, SVR and ADC from 2D GRE and 3D GRSK DWI, the Spearman correlation coefficients were 0.975, 0.900, and 1.000, with corresponding p‐values of 0.005, 0.037, and < 0.001, and the Bland–Altman analysis had biases of −3.19%, 1.44%, and −3.71%, respectively. Furthermore, Lm and ADC in patients were significantly higher (p = 0.008 and p = 0.008) than those in AMC, while SVR was notably reduced (p = 0.008). Conclusion: The proposed method could obtain isotropic resolution DW images with four b‐values within an 11.4 s breath‐hold duration, mitigating the problems of long scan time and large slice thickness in conventional DWI. [ABSTRACT FROM AUTHOR] |
| Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 185839740 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Hyperpolarized <superscript>129</superscript>Xe diffusion‐weighted MRI of the lung with 3D golden‐angle radial sampling and keyhole reconstruction. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Shen%2C+Luyang%22">Shen, Luyang</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Li%2C+Haidong%22">Li, Haidong</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Fang%2C+Yuan%22">Fang, Yuan</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Luo%2C+Ming%22">Luo, Ming</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Li%2C+Yecheng%22">Li, Yecheng</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Zhou%2C+Qian%22">Zhou, Qian</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Rao%2C+Qiuchen%22">Rao, Qiuchen</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Zhang%2C+Ming%22">Zhang, Ming</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Zhao%2C+Xiuchao%22">Zhao, Xiuchao</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Shi%2C+Lei%22">Shi, Lei</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Han%2C+Yeqing%22">Han, Yeqing</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Guo%2C+Fumin%22">Guo, Fumin</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Zhou%2C+Xin%22">Zhou, Xin</searchLink><relatesTo>1,2,3</relatesTo> (AUTHOR)<i> xinzhou@wipm.ac.cn</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Jun2025, Vol. 52 Issue 6, p4068-4078. 11p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Diffusion+magnetic+resonance+imaging%22">Diffusion magnetic resonance imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Xenon%22">Xenon</searchLink><br /><searchLink fieldCode="DE" term="%22Compressed+sensing%22">Compressed sensing</searchLink><br /><searchLink fieldCode="DE" term="%22Lungs%22">Lungs</searchLink><br /><searchLink fieldCode="DE" term="%22Pulmonary+function+tests%22">Pulmonary function tests</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Background: Hyperpolarized (HP) 129Xe multiple b‐values diffusion‐weighted imaging (DWI) facilitates the assessment of pulmonary morphology. However, conventional DWI method, such as 2D GRE DWI, is limited in its application due to the long acquisition time and relatively thick slice. Purpose: To develop a method combining 3D golden‐angle radial sampling with keyhole reconstruction (GRSK) for accelerating 129Xe multiple b‐values DWI and obtaining thinner slice. Methods: For 3D GRSK DWI, 3D kooshball golden‐angle radial sampling was used for image acquisition, with each spoke assigned to 1 of 4 b‐values, and keyhole method was applied for reconstructing DW images under different b‐values. 2D fully sampled GRE DWI and 3D GRSK DWI were obtained in five healthy young volunteers (HYV; 25 [24–26] years). Lung morphological parameter maps, including mean linear intercept (Lm) and surface‐to‐volume ratio (SVR), were generated using a cylinder model (CM) from the four b‐values DW images, and apparent diffusion coefficient (ADC) maps were derived through mono‐exponential fitting. Spearman correlation and Bland‐Altman analysis were performed to compare Lm, SVR and ADC from 2D GRE and 3D GRSK DWI. In addition, 3D GRSK DWI was applied in five emphysema patients (66 [60–69] years) and five age‐matched healthy controls (AMC; 59 [54–68] years), and Lm, SVR and ADC maps were also derived. Wilcoxon rank‐sum test was utilized to contrast Lm, SVR and ADC from patients with those from AMC. Results: DW images with an isotropic resolution (5 mm) were obtained with 3D GRSK DWI within 11.4 s. In comparison, 2D GRE DWI acquired four slices with 30 mm thickness in 15.9 s. For Lm, SVR and ADC from 2D GRE and 3D GRSK DWI, the Spearman correlation coefficients were 0.975, 0.900, and 1.000, with corresponding p‐values of 0.005, 0.037, and < 0.001, and the Bland–Altman analysis had biases of −3.19%, 1.44%, and −3.71%, respectively. Furthermore, Lm and ADC in patients were significantly higher (p = 0.008 and p = 0.008) than those in AMC, while SVR was notably reduced (p = 0.008). Conclusion: The proposed method could obtain isotropic resolution DW images with four b‐values within an 11.4 s breath‐hold duration, mitigating the problems of long scan time and large slice thickness in conventional DWI. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=185839740 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1002/mp.17719 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 11 StartPage: 4068 Subjects: – SubjectFull: Diffusion magnetic resonance imaging Type: general – SubjectFull: Xenon Type: general – SubjectFull: Compressed sensing Type: general – SubjectFull: Lungs Type: general – SubjectFull: Pulmonary function tests Type: general Titles: – TitleFull: Hyperpolarized 129Xe diffusion‐weighted MRI of the lung with 3D golden‐angle radial sampling and keyhole reconstruction. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Shen, Luyang – PersonEntity: Name: NameFull: Li, Haidong – PersonEntity: Name: NameFull: Fang, Yuan – PersonEntity: Name: NameFull: Luo, Ming – PersonEntity: Name: NameFull: Li, Yecheng – PersonEntity: Name: NameFull: Zhou, Qian – PersonEntity: Name: NameFull: Rao, Qiuchen – PersonEntity: Name: NameFull: Zhang, Ming – PersonEntity: Name: NameFull: Zhao, Xiuchao – PersonEntity: Name: NameFull: Shi, Lei – PersonEntity: Name: NameFull: Han, Yeqing – PersonEntity: Name: NameFull: Guo, Fumin – PersonEntity: Name: NameFull: Zhou, Xin IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 06 Text: Jun2025 Type: published Y: 2025 Identifiers: – Type: issn-print Value: 00942405 Numbering: – Type: volume Value: 52 – Type: issue Value: 6 Titles: – TitleFull: Medical Physics Type: main |
| ResultId | 1 |