Analytical model for pulse pileup spectra and count statistics in photon counting detectors with seminonparalyzable behavior.

Saved in:
Bibliographic Details
Title: Analytical model for pulse pileup spectra and count statistics in photon counting detectors with seminonparalyzable behavior.
Authors: Yang, Yirong1,2 (AUTHOR) yryangd@stanford.edu, Pelc, Norbert J.2 (AUTHOR), Wang, Adam S.1,2 (AUTHOR)
Source: Medical Physics. Jun2025, Vol. 52 Issue 6, p3658-3674. 17p.
Subjects: Photon counting, Computed tomography, Statistics, Simulation methods & models, Noise, Monte Carlo method
Abstract: Background: Photon counting detectors (PCDs) with energy discriminating capabilities enable quantitative imaging of materials. However, the accuracy of estimates may be substantially degraded due to pulse pileup effects (PPEs) at high count rates. Accurate description of the output spectrum and count rate behavior of a PCD subject to pulse pileup is crucial to the development of photon counting computed tomography (PCCT). Purpose: This study presents a fully analytical model to accurately predict the pulse pileup spectrum and count statistics (mean and covariance of energy‐binned counts) for a non‐paralyzable detector with nonzero pulse length and, therefore, seminonparalyzable behavior, that is, retriggering of dead time by pulses incident during the previous dead time. Methods: We recursively computed the probability density function (PDF) of pulse pileup spectra at different pulse pileup orders. To do this, we considered the following factors: the unipolar pulse shape, the incident pulse spectrum, the distribution of time intervals between incident pulses, and the trigger threshold. We then derived the count rate and spectrum‐dependent expression of total count statistics (mean and variance of total counts) based on renewal theory. We simulated a non‐paralyzable PCD using Monte Carlo simulation to separately validate the spectrum and count statistics model outputs. Finally, we investigated the model accuracy in predicting material decomposition noise using the Cramér–Rao lower bound (CRLB) and a multibin system model. A comparison between predictions of the proposed model and Monte Carlo simulation is presented. Results: The results show excellent agreement between the proposed model prediction of pulse pileup spectrum and count statistics and Monte Carlo simulation for relative count rates (the average number of counts detected during one dead time, λτ$\lambda \tau $) of up to 2.5$2.5$. The coefficient of variation (CV) values between the spectra from model prediction and Monte Carlo simulation are less than 9%$9\% $, and the coefficient of determination values, R2${R}^2$, between the count statistics from model prediction and Monte Carlo simulation are greater than 0.99$0.99$. The proposed model also accurately predicts material decomposition noise for a non‐paralyzable PCD for relative count rates of up to 1.0$1.0$, with relative error (RE) less than 11%$11\% $. Conclusions: We developed a fully analytical model of the pulse pileup spectrum and count statistics for a non‐paralyzable detector model with nonzero pulse length. The model predictions agree with the Monte Carlo simulation outputs. This model could be used to correct and compensate for pulse pileup when imaging with PCDs. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 185839763
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Analytical model for pulse pileup spectra and count statistics in photon counting detectors with seminonparalyzable behavior.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Yang%2C+Yirong%22">Yang, Yirong</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<i> yryangd@stanford.edu</i><br /><searchLink fieldCode="AR" term="%22Pelc%2C+Norbert+J%2E%22">Pelc, Norbert J.</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Wang%2C+Adam+S%2E%22">Wang, Adam S.</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Jun2025, Vol. 52 Issue 6, p3658-3674. 17p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Photon+counting%22">Photon counting</searchLink><br /><searchLink fieldCode="DE" term="%22Computed+tomography%22">Computed tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Statistics%22">Statistics</searchLink><br /><searchLink fieldCode="DE" term="%22Simulation+methods+%26+models%22">Simulation methods & models</searchLink><br /><searchLink fieldCode="DE" term="%22Noise%22">Noise</searchLink><br /><searchLink fieldCode="DE" term="%22Monte+Carlo+method%22">Monte Carlo method</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Background: Photon counting detectors (PCDs) with energy discriminating capabilities enable quantitative imaging of materials. However, the accuracy of estimates may be substantially degraded due to pulse pileup effects (PPEs) at high count rates. Accurate description of the output spectrum and count rate behavior of a PCD subject to pulse pileup is crucial to the development of photon counting computed tomography (PCCT). Purpose: This study presents a fully analytical model to accurately predict the pulse pileup spectrum and count statistics (mean and covariance of energy‐binned counts) for a non‐paralyzable detector with nonzero pulse length and, therefore, seminonparalyzable behavior, that is, retriggering of dead time by pulses incident during the previous dead time. Methods: We recursively computed the probability density function (PDF) of pulse pileup spectra at different pulse pileup orders. To do this, we considered the following factors: the unipolar pulse shape, the incident pulse spectrum, the distribution of time intervals between incident pulses, and the trigger threshold. We then derived the count rate and spectrum‐dependent expression of total count statistics (mean and variance of total counts) based on renewal theory. We simulated a non‐paralyzable PCD using Monte Carlo simulation to separately validate the spectrum and count statistics model outputs. Finally, we investigated the model accuracy in predicting material decomposition noise using the Cramér–Rao lower bound (CRLB) and a multibin system model. A comparison between predictions of the proposed model and Monte Carlo simulation is presented. Results: The results show excellent agreement between the proposed model prediction of pulse pileup spectrum and count statistics and Monte Carlo simulation for relative count rates (the average number of counts detected during one dead time, λτ$\lambda \tau $) of up to 2.5$2.5$. The coefficient of variation (CV) values between the spectra from model prediction and Monte Carlo simulation are less than 9%$9\% $, and the coefficient of determination values, R2${R}^2$, between the count statistics from model prediction and Monte Carlo simulation are greater than 0.99$0.99$. The proposed model also accurately predicts material decomposition noise for a non‐paralyzable PCD for relative count rates of up to 1.0$1.0$, with relative error (RE) less than 11%$11\% $. Conclusions: We developed a fully analytical model of the pulse pileup spectrum and count statistics for a non‐paralyzable detector model with nonzero pulse length. The model predictions agree with the Monte Carlo simulation outputs. This model could be used to correct and compensate for pulse pileup when imaging with PCDs. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=185839763
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mp.17746
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 17
        StartPage: 3658
    Subjects:
      – SubjectFull: Photon counting
        Type: general
      – SubjectFull: Computed tomography
        Type: general
      – SubjectFull: Statistics
        Type: general
      – SubjectFull: Simulation methods & models
        Type: general
      – SubjectFull: Noise
        Type: general
      – SubjectFull: Monte Carlo method
        Type: general
    Titles:
      – TitleFull: Analytical model for pulse pileup spectra and count statistics in photon counting detectors with seminonparalyzable behavior.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Yang, Yirong
      – PersonEntity:
          Name:
            NameFull: Pelc, Norbert J.
      – PersonEntity:
          Name:
            NameFull: Wang, Adam S.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 06
              Text: Jun2025
              Type: published
              Y: 2025
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 52
            – Type: issue
              Value: 6
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1