Examination of aperture layout designs for an adaptive‐stationary multi‐pinhole brain‐dedicated SPECT system.

Saved in:
Bibliographic Details
Title: Examination of aperture layout designs for an adaptive‐stationary multi‐pinhole brain‐dedicated SPECT system.
Authors: Kalluri, Kesava S.1 (AUTHOR) Kesava.Kalluri@umassmed.edu, Zeraatkar, Navid1 (AUTHOR), Auer, Benjamin1,2 (AUTHOR), Pells, Sophia1 (AUTHOR), Pretorius, P. Hendrik1 (AUTHOR), Richards, Garrett R.3 (AUTHOR), May, Micaehla3 (AUTHOR), Momsen, Neil3 (AUTHOR), Doty, Kimberly3 (AUTHOR), Gonzales, Maria Ruiz3 (AUTHOR), Fromme, Timothy4 (AUTHOR), Truong, Kevin5 (AUTHOR), Kupinski, Matthew A3 (AUTHOR), Kuo, Phillip H.6 (AUTHOR), Furenlid, Lars R.3 (AUTHOR), King, Michael A.1 (AUTHOR)
Source: Medical Physics. Jun2025, Vol. 52 Issue 6, p3734-3759. 26p.
Subjects: Brain imaging, Image quality analysis, Single-photon emission computed tomography, Numerical apertures, Scintillation cameras, Optical apertures, Simulation methods & models, Sensitivity analysis
Abstract: Background: Organ specific multi‐pinhole (MPH) SPECT imaging could potentially improve the sensitivity/resolution trade‐off and image quality (IQ), while facilitating the use of a variety of imaging‐agents, thereby addressing diagnostic, quantitative, and research clinical needs. Purpose: Investigate through simulation six different MPH aperture‐layout designs, plus variations in projection multiplexing (MUX) and truncation, for a prototype brain‐dedicated MPH SPECT system, named AdaptiSPECT‐C, to understand tradeoffs for such choices and guide selection of an optimal design for construction of the actual AdaptiSPECT‐C system. Methods: The prototype AdaptiSPECT‐C system investigated herein employs 25 MPH gamma‐camera modules arranged in three rings to image a 21 cm diameter spherical volume‐of‐interest (VOI). With a focal point (FP) to center of detector distances of 38.7 cm, the pinhole aperture diameters were constrained to provide a calculated spatial resolution of 8 mm at the FP. Variations in the number of pinhole (PH) apertures, FP to aperture distance, PH layout, temporal changes in MUX, and extent‐of‐truncation of the projection images were investigated. Designs of the aperture layouts were used to create inputs for GATE and analytic simulations of a sphere phantom with uniform Tc‐99 m activity filling the VOI, to assess MUX, detector utilization, and uniformity in reconstructed slices. We investigated axial and angular sampling using customized‐spherical Defrise and Derenzo phantoms. Finally, we assessed reconstructed IQ and activity quantification in reconstructions of analytic simulations of the XCAT digital anthropomorphic phantom with activity and attenuation distributions mimicking clinical‐SPECT brain‐perfusion imaging. For each phantom, comparison was also made to imaging with a dual‐headed SPECT system with low‐energy high‐resolution (LEHR) parallel‐hole (Vertex high resolution [VXHR]) collimators. Results: Sensitivity at the FP (SENS) for a Tc‐99 m source in air calculated relative to a clinical dual‐headed SPECT system with VXHR collimators was 2.7x higher for a single aperture with no MUX or truncation, increased to 5.7x for five apertures with limited VOI truncation and MUX, and decreased to 2.5x with 13 apertures with limited MUX. For the spherical tub phantom, limited truncation did not impact uniformity, MUX decreased it, and temporal shuttering of projections helped lessen this impact. Visually, the 6.4 mm rods were generally well differentiated for the single central apertures. For designs with four or more apertures, all the 4.8 mm rods were well differentiated visually. Projection images of the XCAT phantom acquired for an imaging time that would result in the minimum clinically recommended count‐level for brain perfusion imaging with parallel‐hole collimators, showed low MUX of the brain structures for all of the MPH aperture layout designs. The best reconstructions for the XCAT phantom, both visually and quantitatively, were obtained with the design using 4‐ or 5‐PH‐apertures for the aperture‐layout design that included MUX and some truncation of imaging. Conclusions: We determined for a prototype brain‐dedicated MPH SPECT employing 25 camera modules in three rings with different PH layout designs imaging a 21 cm diameter spherical VOI, that a system with five apertures per module provided the best SENS, and IQ of the XCAT brain phantom, both visually and numerically. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 185839832
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Examination of aperture layout designs for an adaptive‐stationary multi‐pinhole brain‐dedicated SPECT system.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Kalluri%2C+Kesava+S%2E%22">Kalluri, Kesava S.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> Kesava.Kalluri@umassmed.edu</i><br /><searchLink fieldCode="AR" term="%22Zeraatkar%2C+Navid%22">Zeraatkar, Navid</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Auer%2C+Benjamin%22">Auer, Benjamin</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Pells%2C+Sophia%22">Pells, Sophia</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Pretorius%2C+P%2E+Hendrik%22">Pretorius, P. Hendrik</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Richards%2C+Garrett+R%2E%22">Richards, Garrett R.</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22May%2C+Micaehla%22">May, Micaehla</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Momsen%2C+Neil%22">Momsen, Neil</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Doty%2C+Kimberly%22">Doty, Kimberly</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Gonzales%2C+Maria+Ruiz%22">Gonzales, Maria Ruiz</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Fromme%2C+Timothy%22">Fromme, Timothy</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Truong%2C+Kevin%22">Truong, Kevin</searchLink><relatesTo>5</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kupinski%2C+Matthew+A%22">Kupinski, Matthew A</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kuo%2C+Phillip+H%2E%22">Kuo, Phillip H.</searchLink><relatesTo>6</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Furenlid%2C+Lars+R%2E%22">Furenlid, Lars R.</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22King%2C+Michael+A%2E%22">King, Michael A.</searchLink><relatesTo>1</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Jun2025, Vol. 52 Issue 6, p3734-3759. 26p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Brain+imaging%22">Brain imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Image+quality+analysis%22">Image quality analysis</searchLink><br /><searchLink fieldCode="DE" term="%22Single-photon+emission+computed+tomography%22">Single-photon emission computed tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Numerical+apertures%22">Numerical apertures</searchLink><br /><searchLink fieldCode="DE" term="%22Scintillation+cameras%22">Scintillation cameras</searchLink><br /><searchLink fieldCode="DE" term="%22Optical+apertures%22">Optical apertures</searchLink><br /><searchLink fieldCode="DE" term="%22Simulation+methods+%26+models%22">Simulation methods & models</searchLink><br /><searchLink fieldCode="DE" term="%22Sensitivity+analysis%22">Sensitivity analysis</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Background: Organ specific multi‐pinhole (MPH) SPECT imaging could potentially improve the sensitivity/resolution trade‐off and image quality (IQ), while facilitating the use of a variety of imaging‐agents, thereby addressing diagnostic, quantitative, and research clinical needs. Purpose: Investigate through simulation six different MPH aperture‐layout designs, plus variations in projection multiplexing (MUX) and truncation, for a prototype brain‐dedicated MPH SPECT system, named AdaptiSPECT‐C, to understand tradeoffs for such choices and guide selection of an optimal design for construction of the actual AdaptiSPECT‐C system. Methods: The prototype AdaptiSPECT‐C system investigated herein employs 25 MPH gamma‐camera modules arranged in three rings to image a 21 cm diameter spherical volume‐of‐interest (VOI). With a focal point (FP) to center of detector distances of 38.7 cm, the pinhole aperture diameters were constrained to provide a calculated spatial resolution of 8 mm at the FP. Variations in the number of pinhole (PH) apertures, FP to aperture distance, PH layout, temporal changes in MUX, and extent‐of‐truncation of the projection images were investigated. Designs of the aperture layouts were used to create inputs for GATE and analytic simulations of a sphere phantom with uniform Tc‐99 m activity filling the VOI, to assess MUX, detector utilization, and uniformity in reconstructed slices. We investigated axial and angular sampling using customized‐spherical Defrise and Derenzo phantoms. Finally, we assessed reconstructed IQ and activity quantification in reconstructions of analytic simulations of the XCAT digital anthropomorphic phantom with activity and attenuation distributions mimicking clinical‐SPECT brain‐perfusion imaging. For each phantom, comparison was also made to imaging with a dual‐headed SPECT system with low‐energy high‐resolution (LEHR) parallel‐hole (Vertex high resolution [VXHR]) collimators. Results: Sensitivity at the FP (SENS) for a Tc‐99 m source in air calculated relative to a clinical dual‐headed SPECT system with VXHR collimators was 2.7x higher for a single aperture with no MUX or truncation, increased to 5.7x for five apertures with limited VOI truncation and MUX, and decreased to 2.5x with 13 apertures with limited MUX. For the spherical tub phantom, limited truncation did not impact uniformity, MUX decreased it, and temporal shuttering of projections helped lessen this impact. Visually, the 6.4 mm rods were generally well differentiated for the single central apertures. For designs with four or more apertures, all the 4.8 mm rods were well differentiated visually. Projection images of the XCAT phantom acquired for an imaging time that would result in the minimum clinically recommended count‐level for brain perfusion imaging with parallel‐hole collimators, showed low MUX of the brain structures for all of the MPH aperture layout designs. The best reconstructions for the XCAT phantom, both visually and quantitatively, were obtained with the design using 4‐ or 5‐PH‐apertures for the aperture‐layout design that included MUX and some truncation of imaging. Conclusions: We determined for a prototype brain‐dedicated MPH SPECT employing 25 camera modules in three rings with different PH layout designs imaging a 21 cm diameter spherical VOI, that a system with five apertures per module provided the best SENS, and IQ of the XCAT brain phantom, both visually and numerically. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=185839832
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mp.17866
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 26
        StartPage: 3734
    Subjects:
      – SubjectFull: Brain imaging
        Type: general
      – SubjectFull: Image quality analysis
        Type: general
      – SubjectFull: Single-photon emission computed tomography
        Type: general
      – SubjectFull: Numerical apertures
        Type: general
      – SubjectFull: Scintillation cameras
        Type: general
      – SubjectFull: Optical apertures
        Type: general
      – SubjectFull: Simulation methods & models
        Type: general
      – SubjectFull: Sensitivity analysis
        Type: general
    Titles:
      – TitleFull: Examination of aperture layout designs for an adaptive‐stationary multi‐pinhole brain‐dedicated SPECT system.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Kalluri, Kesava S.
      – PersonEntity:
          Name:
            NameFull: Zeraatkar, Navid
      – PersonEntity:
          Name:
            NameFull: Auer, Benjamin
      – PersonEntity:
          Name:
            NameFull: Pells, Sophia
      – PersonEntity:
          Name:
            NameFull: Pretorius, P. Hendrik
      – PersonEntity:
          Name:
            NameFull: Richards, Garrett R.
      – PersonEntity:
          Name:
            NameFull: May, Micaehla
      – PersonEntity:
          Name:
            NameFull: Momsen, Neil
      – PersonEntity:
          Name:
            NameFull: Doty, Kimberly
      – PersonEntity:
          Name:
            NameFull: Gonzales, Maria Ruiz
      – PersonEntity:
          Name:
            NameFull: Fromme, Timothy
      – PersonEntity:
          Name:
            NameFull: Truong, Kevin
      – PersonEntity:
          Name:
            NameFull: Kupinski, Matthew A
      – PersonEntity:
          Name:
            NameFull: Kuo, Phillip H.
      – PersonEntity:
          Name:
            NameFull: Furenlid, Lars R.
      – PersonEntity:
          Name:
            NameFull: King, Michael A.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 06
              Text: Jun2025
              Type: published
              Y: 2025
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 52
            – Type: issue
              Value: 6
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1