A Critical Review of Methods for Hold-Up Time (Volume) Determination.

Saved in:
Bibliographic Details
Title: A Critical Review of Methods for Hold-Up Time (Volume) Determination.
Authors: Deineka, V. I.1 (AUTHOR) deineka@bsuedu.ru
Source: Journal of Analytical Chemistry. May2025, Vol. 80 Issue 5, p794-800. 7p.
Subjects: Sorbents, Phase velocity, Chromatographic analysis, Organic solvents, Molecules, RF values (Chromatography)
Abstract: Known methods for determining hold-up time, essential for calculating retention factors and related chromatographic patterns, are reviewed. The retention factor, initially defined in the theoretical plate model for chromatography on non-porous sorbents, can be adapted to porous sorbents containing mobile phase components in stagnant zones within the sorbent pores. However, in this case, the zone of an unretained solute moves slower than the actual velocity of the mobile phase. The most commonly used approaches from previously proposed methods are considered, taking into account new experimental data. The possible presence of gallery pores in sorbents raises concerns about the gravimetric method. Furthermore, this method, like many others, does not take into account differences in retention mechanisms between adsorption and absorption. The use of solvents wetting the stationary phase likely leads to the penetration of solvent molecule into the attached phase and should yield a hold-up volume applicable to the absorption mechanism. If the solvent poorly wets the stationary phase, the obtained hold-up volume loses clear physical meaning. Calculations of hold-up time based on the retention of deuterated water are more appropriate to the determination of hold-up time in adsorption-based retention but may result in overestimated values due to water adsorption on residual silanol groups. The use of deuterated organic solvents for the same purpose raises additional concerns. Using inorganic salts as hold-up volume markers may lead to inaccuracies due to exclusion effects, which should also be considered in other methods. The homologous series method is not entirely reliable for several reasons discussed in the text. Similarly, the system peak method cannot provide unambiguous confirmation, as it may correspond to retention with an uncertain degree of exclusion effects. Consequently, the problem remains unresolved, and the development of new specialized approaches is required. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Analytical Chemistry is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 185965424
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: A Critical Review of Methods for Hold-Up Time (Volume) Determination.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Deineka%2C+V%2E+I%2E%22">Deineka, V. I.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> deineka@bsuedu.ru</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Journal+of+Analytical+Chemistry%22">Journal of Analytical Chemistry</searchLink>. May2025, Vol. 80 Issue 5, p794-800. 7p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Sorbents%22">Sorbents</searchLink><br /><searchLink fieldCode="DE" term="%22Phase+velocity%22">Phase velocity</searchLink><br /><searchLink fieldCode="DE" term="%22Chromatographic+analysis%22">Chromatographic analysis</searchLink><br /><searchLink fieldCode="DE" term="%22Organic+solvents%22">Organic solvents</searchLink><br /><searchLink fieldCode="DE" term="%22Molecules%22">Molecules</searchLink><br /><searchLink fieldCode="DE" term="%22RF+values+%28Chromatography%29%22">RF values (Chromatography)</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Known methods for determining hold-up time, essential for calculating retention factors and related chromatographic patterns, are reviewed. The retention factor, initially defined in the theoretical plate model for chromatography on non-porous sorbents, can be adapted to porous sorbents containing mobile phase components in stagnant zones within the sorbent pores. However, in this case, the zone of an unretained solute moves slower than the actual velocity of the mobile phase. The most commonly used approaches from previously proposed methods are considered, taking into account new experimental data. The possible presence of gallery pores in sorbents raises concerns about the gravimetric method. Furthermore, this method, like many others, does not take into account differences in retention mechanisms between adsorption and absorption. The use of solvents wetting the stationary phase likely leads to the penetration of solvent molecule into the attached phase and should yield a hold-up volume applicable to the absorption mechanism. If the solvent poorly wets the stationary phase, the obtained hold-up volume loses clear physical meaning. Calculations of hold-up time based on the retention of deuterated water are more appropriate to the determination of hold-up time in adsorption-based retention but may result in overestimated values due to water adsorption on residual silanol groups. The use of deuterated organic solvents for the same purpose raises additional concerns. Using inorganic salts as hold-up volume markers may lead to inaccuracies due to exclusion effects, which should also be considered in other methods. The homologous series method is not entirely reliable for several reasons discussed in the text. Similarly, the system peak method cannot provide unambiguous confirmation, as it may correspond to retention with an uncertain degree of exclusion effects. Consequently, the problem remains unresolved, and the development of new specialized approaches is required. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Journal of Analytical Chemistry is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=185965424
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1134/S1061934825700212
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 7
        StartPage: 794
    Subjects:
      – SubjectFull: Sorbents
        Type: general
      – SubjectFull: Phase velocity
        Type: general
      – SubjectFull: Chromatographic analysis
        Type: general
      – SubjectFull: Organic solvents
        Type: general
      – SubjectFull: Molecules
        Type: general
      – SubjectFull: RF values (Chromatography)
        Type: general
    Titles:
      – TitleFull: A Critical Review of Methods for Hold-Up Time (Volume) Determination.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Deineka, V. I.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 05
              Text: May2025
              Type: published
              Y: 2025
          Identifiers:
            – Type: issn-print
              Value: 10619348
          Numbering:
            – Type: volume
              Value: 80
            – Type: issue
              Value: 5
          Titles:
            – TitleFull: Journal of Analytical Chemistry
              Type: main
ResultId 1