A Finite Element Analysis of a New Dental Implant Design: The Influence of the Diameter, Length, and Material of an Implant on Its Biomechanical Behavior.
Saved in:
| Title: | A Finite Element Analysis of a New Dental Implant Design: The Influence of the Diameter, Length, and Material of an Implant on Its Biomechanical Behavior. |
|---|---|
| Authors: | González-Mederos, Pedro1 (AUTHOR), Rodríguez-Guerra, Jennifer1,2 (AUTHOR), González, Jesús E.1,2,3 (AUTHOR), Picardo, Alberto3,4 (AUTHOR), Torres, Yadir1,4 (AUTHOR) ytorres@us.es |
| Source: | Materials (1996-1944). Jun2025, Vol. 18 Issue 12, p2692. 20p. |
| Subjects: | Compact bone, Cancellous bone, Finite element method, Dental implants, Stress concentration |
| Abstract: | It is widely recognized that excessive stress and/or strain can lead to peri-implant bone atrophy; therefore, the clinical success of dental implants is intrinsically related to their biomechanical behavior. This study evaluates the influence of the diameter, length, and material [Ti6Al4V (α+β Ti) and Ti35Nb7Zr5Ta (β-Ti)] of a novel cylindrical dental implant on stress and strain levels within maxillary bone of type II quality. The implant design aims to ensure an appropriate distribution of stresses and strains within the peri-implant bone structures (cortical and trabecular bones) while also facilitating surgical machining by requiring a simple, linear, and less expensive bone incision. This approach minimizes the risk of thermal necrosis, a common complication in osteotomies for conical implants that can lead to peri-implant bone loss. Using finite element analysis, stress and strain patterns were evaluated in the maxillary second premolar region under static delayed loading. The results reveal that the cortical bone strains remained below the critical threshold (0.003) to prevent resorption. In the trabecular bone, only larger diameter/length configurations satisfied the previous strain criterion. In all simulations, trabecular bone stress remained below 3 MPa, whereas cortical bone stress peaked at 78 MPa. Notably, the implant model with the largest diameter/length minimized stress and strain concentrations in type II bone when compared to smaller designs, thereby demonstrating its biomechanical advantage. [ABSTRACT FROM AUTHOR] |
| Copyright of Materials (1996-1944) is the property of MDPI and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 186261406 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: A Finite Element Analysis of a New Dental Implant Design: The Influence of the Diameter, Length, and Material of an Implant on Its Biomechanical Behavior. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22González-Mederos%2C+Pedro%22">González-Mederos, Pedro</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Rodríguez-Guerra%2C+Jennifer%22">Rodríguez-Guerra, Jennifer</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22González%2C+Jesús+E%2E%22">González, Jesús E.</searchLink><relatesTo>1,2,3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Picardo%2C+Alberto%22">Picardo, Alberto</searchLink><relatesTo>3,4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Torres%2C+Yadir%22">Torres, Yadir</searchLink><relatesTo>1,4</relatesTo> (AUTHOR)<i> ytorres@us.es</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Materials+%281996-1944%29%22">Materials (1996-1944)</searchLink>. Jun2025, Vol. 18 Issue 12, p2692. 20p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Compact+bone%22">Compact bone</searchLink><br /><searchLink fieldCode="DE" term="%22Cancellous+bone%22">Cancellous bone</searchLink><br /><searchLink fieldCode="DE" term="%22Finite+element+method%22">Finite element method</searchLink><br /><searchLink fieldCode="DE" term="%22Dental+implants%22">Dental implants</searchLink><br /><searchLink fieldCode="DE" term="%22Stress+concentration%22">Stress concentration</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: It is widely recognized that excessive stress and/or strain can lead to peri-implant bone atrophy; therefore, the clinical success of dental implants is intrinsically related to their biomechanical behavior. This study evaluates the influence of the diameter, length, and material [Ti6Al4V (α+β Ti) and Ti35Nb7Zr5Ta (β-Ti)] of a novel cylindrical dental implant on stress and strain levels within maxillary bone of type II quality. The implant design aims to ensure an appropriate distribution of stresses and strains within the peri-implant bone structures (cortical and trabecular bones) while also facilitating surgical machining by requiring a simple, linear, and less expensive bone incision. This approach minimizes the risk of thermal necrosis, a common complication in osteotomies for conical implants that can lead to peri-implant bone loss. Using finite element analysis, stress and strain patterns were evaluated in the maxillary second premolar region under static delayed loading. The results reveal that the cortical bone strains remained below the critical threshold (0.003) to prevent resorption. In the trabecular bone, only larger diameter/length configurations satisfied the previous strain criterion. In all simulations, trabecular bone stress remained below 3 MPa, whereas cortical bone stress peaked at 78 MPa. Notably, the implant model with the largest diameter/length minimized stress and strain concentrations in type II bone when compared to smaller designs, thereby demonstrating its biomechanical advantage. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Materials (1996-1944) is the property of MDPI and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=186261406 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.3390/ma18122692 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 20 StartPage: 2692 Subjects: – SubjectFull: Compact bone Type: general – SubjectFull: Cancellous bone Type: general – SubjectFull: Finite element method Type: general – SubjectFull: Dental implants Type: general – SubjectFull: Stress concentration Type: general Titles: – TitleFull: A Finite Element Analysis of a New Dental Implant Design: The Influence of the Diameter, Length, and Material of an Implant on Its Biomechanical Behavior. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: González-Mederos, Pedro – PersonEntity: Name: NameFull: Rodríguez-Guerra, Jennifer – PersonEntity: Name: NameFull: González, Jesús E. – PersonEntity: Name: NameFull: Picardo, Alberto – PersonEntity: Name: NameFull: Torres, Yadir IsPartOfRelationships: – BibEntity: Dates: – D: 15 M: 06 Text: Jun2025 Type: published Y: 2025 Identifiers: – Type: issn-print Value: 19961944 Numbering: – Type: volume Value: 18 – Type: issue Value: 12 Titles: – TitleFull: Materials (1996-1944) Type: main |
| ResultId | 1 |