Impact of High‐Density Mapping on Pulmonary Vein Isolation Durability: A Randomized, Single‐Center Study.

Saved in:
Bibliographic Details
Title: Impact of High‐Density Mapping on Pulmonary Vein Isolation Durability: A Randomized, Single‐Center Study.
Authors: Kajdič, Nina1,2 nina.kajdic@kclj.si, Kalinšek, Tine Prolič3, Antolič, Bor2, Žižek, David1,2, Štublar, Jernej2,3, Demšar, Jure4,5, Kuhelj, Dimitrij6, Jan, Matevž3
Source: Pacing & Clinical Electrophysiology. Jun2025, Vol. 48 Issue 6, p587-597. 11p.
Subjects: Body surface mapping, Statistical sampling, Treatment effectiveness, Randomized controlled trials, Descriptive statistics, Arrhythmia, Atrial fibrillation, Catheter ablation, Disease relapse, Electrophysiology
Abstract: Background: Despite technical progress and novel ablation strategies, pulmonary vein (PV) reconnection still occurs in a substantial proportion of patients. The aim of the study was to determine the impact of the elimination of antral low‐voltage, fragmented electrograms (LFEGMs) identified by high‐density (HD) mapping on the rate of pulmonary vein isolation (PVI) durability. Methods: Sixty patients with paroxysmal atrial fibrillation (PAF) were randomly assigned to a verification of PV entrance block and presence of LFEGMs on antral isolation lines with an HD mapping catheter (HD group) or to a verification of PV entrance block with a circumferential mapping catheter alone (CM group). In the HD group, LFEGMs were additionally ablated. Mandatory reassessment procedure to assess PVI durability and the presence of LFEGMs was performed 12 months after the index procedure or earlier in case of arrhythmia recurrence. Results: A total of 107 out of 116 (92.2%) PVs were found durably isolated in the HD group, and 97 out of 120 (80.8%) PVs in the CM group (p = 0.02). At the reassessment procedure, a total of 7 [3, 12] and 34 [24, 44] LFEGMs were found in the HD and CM groups, respectively (p = 0.00002). Elimination of LFEGMs at the index procedure reduced the likelihood of antral conduction gaps in the same segments at the reassessment. Arrhythmia recurrence rate was similar between the HD and the CM group (7/29, 24.1% vs. 10/30, 33.3%), p = 0.62, respectively. Conclusion: Additional elimination of LFEGMs identified by HD mapping of antral isolation lines after PVI resulted in a significantly higher rate of PVI durability. Trial Registration: ClinicalTrials.gov identifier: (NCT04466358) [ABSTRACT FROM AUTHOR]
Copyright of Pacing & Clinical Electrophysiology is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 186459913
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Impact of High‐Density Mapping on Pulmonary Vein Isolation Durability: A Randomized, Single‐Center Study.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Kajdič%2C+Nina%22">Kajdič, Nina</searchLink><relatesTo>1,2</relatesTo><i> nina.kajdic@kclj.si</i><br /><searchLink fieldCode="AR" term="%22Kalinšek%2C+Tine+Prolič%22">Kalinšek, Tine Prolič</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Antolič%2C+Bor%22">Antolič, Bor</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Žižek%2C+David%22">Žižek, David</searchLink><relatesTo>1,2</relatesTo><br /><searchLink fieldCode="AR" term="%22Štublar%2C+Jernej%22">Štublar, Jernej</searchLink><relatesTo>2,3</relatesTo><br /><searchLink fieldCode="AR" term="%22Demšar%2C+Jure%22">Demšar, Jure</searchLink><relatesTo>4,5</relatesTo><br /><searchLink fieldCode="AR" term="%22Kuhelj%2C+Dimitrij%22">Kuhelj, Dimitrij</searchLink><relatesTo>6</relatesTo><br /><searchLink fieldCode="AR" term="%22Jan%2C+Matevž%22">Jan, Matevž</searchLink><relatesTo>3</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Pacing+%26+Clinical+Electrophysiology%22">Pacing & Clinical Electrophysiology</searchLink>. Jun2025, Vol. 48 Issue 6, p587-597. 11p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Body+surface+mapping%22">Body surface mapping</searchLink><br /><searchLink fieldCode="DE" term="%22Statistical+sampling%22">Statistical sampling</searchLink><br /><searchLink fieldCode="DE" term="%22Treatment+effectiveness%22">Treatment effectiveness</searchLink><br /><searchLink fieldCode="DE" term="%22Randomized+controlled+trials%22">Randomized controlled trials</searchLink><br /><searchLink fieldCode="DE" term="%22Descriptive+statistics%22">Descriptive statistics</searchLink><br /><searchLink fieldCode="DE" term="%22Arrhythmia%22">Arrhythmia</searchLink><br /><searchLink fieldCode="DE" term="%22Atrial+fibrillation%22">Atrial fibrillation</searchLink><br /><searchLink fieldCode="DE" term="%22Catheter+ablation%22">Catheter ablation</searchLink><br /><searchLink fieldCode="DE" term="%22Disease+relapse%22">Disease relapse</searchLink><br /><searchLink fieldCode="DE" term="%22Electrophysiology%22">Electrophysiology</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Background: Despite technical progress and novel ablation strategies, pulmonary vein (PV) reconnection still occurs in a substantial proportion of patients. The aim of the study was to determine the impact of the elimination of antral low‐voltage, fragmented electrograms (LFEGMs) identified by high‐density (HD) mapping on the rate of pulmonary vein isolation (PVI) durability. Methods: Sixty patients with paroxysmal atrial fibrillation (PAF) were randomly assigned to a verification of PV entrance block and presence of LFEGMs on antral isolation lines with an HD mapping catheter (HD group) or to a verification of PV entrance block with a circumferential mapping catheter alone (CM group). In the HD group, LFEGMs were additionally ablated. Mandatory reassessment procedure to assess PVI durability and the presence of LFEGMs was performed 12 months after the index procedure or earlier in case of arrhythmia recurrence. Results: A total of 107 out of 116 (92.2%) PVs were found durably isolated in the HD group, and 97 out of 120 (80.8%) PVs in the CM group (p = 0.02). At the reassessment procedure, a total of 7 [3, 12] and 34 [24, 44] LFEGMs were found in the HD and CM groups, respectively (p = 0.00002). Elimination of LFEGMs at the index procedure reduced the likelihood of antral conduction gaps in the same segments at the reassessment. Arrhythmia recurrence rate was similar between the HD and the CM group (7/29, 24.1% vs. 10/30, 33.3%), p = 0.62, respectively. Conclusion: Additional elimination of LFEGMs identified by HD mapping of antral isolation lines after PVI resulted in a significantly higher rate of PVI durability. Trial Registration: ClinicalTrials.gov identifier: (NCT04466358) [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Pacing & Clinical Electrophysiology is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=186459913
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1111/pace.15196
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 11
        StartPage: 587
    Subjects:
      – SubjectFull: Body surface mapping
        Type: general
      – SubjectFull: Statistical sampling
        Type: general
      – SubjectFull: Treatment effectiveness
        Type: general
      – SubjectFull: Randomized controlled trials
        Type: general
      – SubjectFull: Descriptive statistics
        Type: general
      – SubjectFull: Arrhythmia
        Type: general
      – SubjectFull: Atrial fibrillation
        Type: general
      – SubjectFull: Catheter ablation
        Type: general
      – SubjectFull: Disease relapse
        Type: general
      – SubjectFull: Electrophysiology
        Type: general
    Titles:
      – TitleFull: Impact of High‐Density Mapping on Pulmonary Vein Isolation Durability: A Randomized, Single‐Center Study.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Kajdič, Nina
      – PersonEntity:
          Name:
            NameFull: Kalinšek, Tine Prolič
      – PersonEntity:
          Name:
            NameFull: Antolič, Bor
      – PersonEntity:
          Name:
            NameFull: Žižek, David
      – PersonEntity:
          Name:
            NameFull: Štublar, Jernej
      – PersonEntity:
          Name:
            NameFull: Demšar, Jure
      – PersonEntity:
          Name:
            NameFull: Kuhelj, Dimitrij
      – PersonEntity:
          Name:
            NameFull: Jan, Matevž
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 06
              Text: Jun2025
              Type: published
              Y: 2025
          Identifiers:
            – Type: issn-print
              Value: 01478389
          Numbering:
            – Type: volume
              Value: 48
            – Type: issue
              Value: 6
          Titles:
            – TitleFull: Pacing & Clinical Electrophysiology
              Type: main
ResultId 1