Pre-contoured Plate Fit Assessment for Acetabular Fractures.
Saved in:
| Title: | Pre-contoured Plate Fit Assessment for Acetabular Fractures. |
|---|---|
| Authors: | van Veldhuizen, Willemina A.1 (AUTHOR) w.a.van.veldhuizen@umcg.nl, Assink, Nick1,2 (AUTHOR), Schuurmann, Richte C. L.1,3 (AUTHOR), Firoozabadi, Reza4 (AUTHOR), ten Duis, Kaj1 (AUTHOR), de Vries, Jean-Paul P. M.1 (AUTHOR), Wolterink, Jelmer M.5 (AUTHOR), IJpma, Frank F. A.1 (AUTHOR) |
| Source: | Annals of Biomedical Engineering. Sep2025, Vol. 53 Issue 9, p2299-2308. 10p. |
| Subjects: | Pelvis, Bone plates (Orthopedics), Three-dimensional modeling, Anatomical variation, Operative surgery, Computed tomography, Hip fractures |
| Abstract: | Purpose: Insufficient fitting of pre-contoured plates for acetabular fractures might lead to inadequate fracture reduction, but it is unclear in which patients pre-contoured plates fit adequately. The aims of this study were to assess plate fitting in sex- and height-specific anatomical variations of the hemipelvis, and categorizing the outcomes as moderate or good fit. Methods: 3D models from computed tomography (CT) scans were obtained from a dataset of 200 patients with an intact left hemipelvis. This dataset was divided into eight subgroups, based on sex and body height, and the plate was virtually fitted on each shape. Plate fitting was assessed by computing the iliopectineal line, the quadrilateral slope, and the root mean square distance (RMSD) between each coordinate of the plate and its closest coordinate on the hemipelvis. Results: The mean age was 56 ± 16 years, and the mean height was 173 ± 10 cm. All female pelves had a moderate fit, mainly because the plate length either exceeded the iliopectineal line length, or the plate's anterior aspect was directed too ventrally. Three out of four male pelves had a good fit. Only the small height subgroup (<175 cm) showed a moderate fit due to the plate length exceeding the iliopectineal line length and a relatively high median RMSD value (1.5 [0.8–2.0] mm) in mid-section of the plate. Conclusions: In acetabular fracture surgery, both visual and quantitative evaluation of suprapectineal plate fitting in sex- and body height-specific subgroups showed moderate fitting in female pelvic shapes, indicating a need for substantial intraoperative bending. This suggests the need for different sizes and contours of future suprapectineal plates in acetabular fracture surgery. [ABSTRACT FROM AUTHOR] |
| Copyright of Annals of Biomedical Engineering is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 187624806 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Pre-contoured Plate Fit Assessment for Acetabular Fractures. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22van+Veldhuizen%2C+Willemina+A%2E%22">van Veldhuizen, Willemina A.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> w.a.van.veldhuizen@umcg.nl</i><br /><searchLink fieldCode="AR" term="%22Assink%2C+Nick%22">Assink, Nick</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Schuurmann%2C+Richte+C%2E+L%2E%22">Schuurmann, Richte C. L.</searchLink><relatesTo>1,3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Firoozabadi%2C+Reza%22">Firoozabadi, Reza</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22ten+Duis%2C+Kaj%22">ten Duis, Kaj</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22de+Vries%2C+Jean-Paul+P%2E+M%2E%22">de Vries, Jean-Paul P. M.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Wolterink%2C+Jelmer+M%2E%22">Wolterink, Jelmer M.</searchLink><relatesTo>5</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22IJpma%2C+Frank+F%2E+A%2E%22">IJpma, Frank F. A.</searchLink><relatesTo>1</relatesTo> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Annals+of+Biomedical+Engineering%22">Annals of Biomedical Engineering</searchLink>. Sep2025, Vol. 53 Issue 9, p2299-2308. 10p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Pelvis%22">Pelvis</searchLink><br /><searchLink fieldCode="DE" term="%22Bone+plates+%28Orthopedics%29%22">Bone plates (Orthopedics)</searchLink><br /><searchLink fieldCode="DE" term="%22Three-dimensional+modeling%22">Three-dimensional modeling</searchLink><br /><searchLink fieldCode="DE" term="%22Anatomical+variation%22">Anatomical variation</searchLink><br /><searchLink fieldCode="DE" term="%22Operative+surgery%22">Operative surgery</searchLink><br /><searchLink fieldCode="DE" term="%22Computed+tomography%22">Computed tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Hip+fractures%22">Hip fractures</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Purpose: Insufficient fitting of pre-contoured plates for acetabular fractures might lead to inadequate fracture reduction, but it is unclear in which patients pre-contoured plates fit adequately. The aims of this study were to assess plate fitting in sex- and height-specific anatomical variations of the hemipelvis, and categorizing the outcomes as moderate or good fit. Methods: 3D models from computed tomography (CT) scans were obtained from a dataset of 200 patients with an intact left hemipelvis. This dataset was divided into eight subgroups, based on sex and body height, and the plate was virtually fitted on each shape. Plate fitting was assessed by computing the iliopectineal line, the quadrilateral slope, and the root mean square distance (RMSD) between each coordinate of the plate and its closest coordinate on the hemipelvis. Results: The mean age was 56 ± 16 years, and the mean height was 173 ± 10 cm. All female pelves had a moderate fit, mainly because the plate length either exceeded the iliopectineal line length, or the plate's anterior aspect was directed too ventrally. Three out of four male pelves had a good fit. Only the small height subgroup (<175 cm) showed a moderate fit due to the plate length exceeding the iliopectineal line length and a relatively high median RMSD value (1.5 [0.8–2.0] mm) in mid-section of the plate. Conclusions: In acetabular fracture surgery, both visual and quantitative evaluation of suprapectineal plate fitting in sex- and body height-specific subgroups showed moderate fitting in female pelvic shapes, indicating a need for substantial intraoperative bending. This suggests the need for different sizes and contours of future suprapectineal plates in acetabular fracture surgery. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Annals of Biomedical Engineering is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=187624806 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1007/s10439-025-03760-9 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 10 StartPage: 2299 Subjects: – SubjectFull: Pelvis Type: general – SubjectFull: Bone plates (Orthopedics) Type: general – SubjectFull: Three-dimensional modeling Type: general – SubjectFull: Anatomical variation Type: general – SubjectFull: Operative surgery Type: general – SubjectFull: Computed tomography Type: general – SubjectFull: Hip fractures Type: general Titles: – TitleFull: Pre-contoured Plate Fit Assessment for Acetabular Fractures. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: van Veldhuizen, Willemina A. – PersonEntity: Name: NameFull: Assink, Nick – PersonEntity: Name: NameFull: Schuurmann, Richte C. L. – PersonEntity: Name: NameFull: Firoozabadi, Reza – PersonEntity: Name: NameFull: ten Duis, Kaj – PersonEntity: Name: NameFull: de Vries, Jean-Paul P. M. – PersonEntity: Name: NameFull: Wolterink, Jelmer M. – PersonEntity: Name: NameFull: IJpma, Frank F. A. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 09 Text: Sep2025 Type: published Y: 2025 Identifiers: – Type: issn-print Value: 00906964 Numbering: – Type: volume Value: 53 – Type: issue Value: 9 Titles: – TitleFull: Annals of Biomedical Engineering Type: main |
| ResultId | 1 |