Investigations for determination of Gd and Sm isotopic compositions in spent nuclear fuels samples by MC ICPMS

Saved in:
Bibliographic Details
Title: Investigations for determination of Gd and Sm isotopic compositions in spent nuclear fuels samples by MC ICPMS
Authors: Isnard, H. helene.isnard@cea.fr, Brennetot, R.1, Caussignac, C.1, Caussignac, N.1, Chartier, F.1
Source: International Journal of Mass Spectrometry. Nov2005, Vol. 246 Issue 1-3, p66-73. 8p.
Subjects: Rare earth metals, Radioactive substances, Mass spectrometry, Spectrum analysis
Abstract: Abstract: Precise isotopic determination of gadolinium and samarium in spent nuclear fuels is necessary to validate neutronic calculation codes. This study presents an analytical strategy to correct mass bias phenomenon inherent to MC ICPMS for precise and accurate samarium and gadolinium isotope measurements. An external standard bracketing approach to correct for mass discrimination and an exponential law fractionation correction have been applied in this work. Due to the lack of isotopic reference materials for Gd and Sm, the reproducibility of all of the isotopic ratios has been evaluated on the basis of natural spex solution commonly used for ICPMS. These solutions have been analysed for comparison and discussion about their representative isotopic values by thermal ionization mass spectrometry. On the basis of TIMS and MC ICPMS investigations, it was observed that: (1) the choice in representative isotopic values of the elements are essential to obtain accurate isotopic results and (2) the dependence of the mass bias of gadolinium and samarium masses must be taken into account for precise and accurate isotopic results. A reproducibility better than 0.1% was obtained with extensive measurements of Gd and Sm solutions by MC ICPMS. When measured isotope intensities were high enough, standard deviation of Gd and Sm isotopic ratios for purified fractions of Gd and Sm fuel samples were better than 0.2%. From the results obtained in this study, the potential of MC ICPMS techniques for determination of precise and accurate Gd and Sm isotopic compositions was clearly demonstrated for nuclear applications. [Copyright &y& Elsevier]
Copyright of International Journal of Mass Spectrometry is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 18782748
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Investigations for determination of Gd and Sm isotopic compositions in spent nuclear fuels samples by MC ICPMS
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Isnard%2C+H%2E%22">Isnard, H.</searchLink><i> helene.isnard@cea.fr</i><br /><searchLink fieldCode="AR" term="%22Brennetot%2C+R%2E%22">Brennetot, R.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Caussignac%2C+C%2E%22">Caussignac, C.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Caussignac%2C+N%2E%22">Caussignac, N.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Chartier%2C+F%2E%22">Chartier, F.</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22International+Journal+of+Mass+Spectrometry%22">International Journal of Mass Spectrometry</searchLink>. Nov2005, Vol. 246 Issue 1-3, p66-73. 8p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Rare+earth+metals%22">Rare earth metals</searchLink><br /><searchLink fieldCode="DE" term="%22Radioactive+substances%22">Radioactive substances</searchLink><br /><searchLink fieldCode="DE" term="%22Mass+spectrometry%22">Mass spectrometry</searchLink><br /><searchLink fieldCode="DE" term="%22Spectrum+analysis%22">Spectrum analysis</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Abstract: Precise isotopic determination of gadolinium and samarium in spent nuclear fuels is necessary to validate neutronic calculation codes. This study presents an analytical strategy to correct mass bias phenomenon inherent to MC ICPMS for precise and accurate samarium and gadolinium isotope measurements. An external standard bracketing approach to correct for mass discrimination and an exponential law fractionation correction have been applied in this work. Due to the lack of isotopic reference materials for Gd and Sm, the reproducibility of all of the isotopic ratios has been evaluated on the basis of natural spex solution commonly used for ICPMS. These solutions have been analysed for comparison and discussion about their representative isotopic values by thermal ionization mass spectrometry. On the basis of TIMS and MC ICPMS investigations, it was observed that: (1) the choice in representative isotopic values of the elements are essential to obtain accurate isotopic results and (2) the dependence of the mass bias of gadolinium and samarium masses must be taken into account for precise and accurate isotopic results. A reproducibility better than 0.1% was obtained with extensive measurements of Gd and Sm solutions by MC ICPMS. When measured isotope intensities were high enough, standard deviation of Gd and Sm isotopic ratios for purified fractions of Gd and Sm fuel samples were better than 0.2%. From the results obtained in this study, the potential of MC ICPMS techniques for determination of precise and accurate Gd and Sm isotopic compositions was clearly demonstrated for nuclear applications. [Copyright &y& Elsevier]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of International Journal of Mass Spectrometry is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=18782748
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.ijms.2005.08.008
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 8
        StartPage: 66
    Subjects:
      – SubjectFull: Rare earth metals
        Type: general
      – SubjectFull: Radioactive substances
        Type: general
      – SubjectFull: Mass spectrometry
        Type: general
      – SubjectFull: Spectrum analysis
        Type: general
    Titles:
      – TitleFull: Investigations for determination of Gd and Sm isotopic compositions in spent nuclear fuels samples by MC ICPMS
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Isnard, H.
      – PersonEntity:
          Name:
            NameFull: Brennetot, R.
      – PersonEntity:
          Name:
            NameFull: Caussignac, C.
      – PersonEntity:
          Name:
            NameFull: Caussignac, N.
      – PersonEntity:
          Name:
            NameFull: Chartier, F.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 11
              Text: Nov2005
              Type: published
              Y: 2005
          Identifiers:
            – Type: issn-print
              Value: 13873806
          Numbering:
            – Type: volume
              Value: 246
            – Type: issue
              Value: 1-3
          Titles:
            – TitleFull: International Journal of Mass Spectrometry
              Type: main
ResultId 1