B0 navigator enables respiratory motion navigation in radial stack‐of‐stars liver Look‐Locker T1 mapping.
Saved in:
| Title: | B |
|---|---|
| Authors: | Stelter, Jonathan1 (AUTHOR) jonathan.stelter@tum.de, Weiss, Kilian2 (AUTHOR), Spieker, Veronika3,4 (AUTHOR), Schnabel, Julia A.3,4,5 (AUTHOR), Braren, Rickmer F.1 (AUTHOR), Karampinos, Dimitrios C.1,6,7 (AUTHOR) |
| Source: | Magnetic Resonance in Medicine. Oct2025, Vol. 94 Issue 4, p1458-1468. 11p. |
| Subjects: | Respiratory mechanics, Motion compensation (Signal processing), Computer-assisted image analysis (Medicine), Automatic tracking, Diagnostic imaging, Magnetic resonance imaging, Image quality in imaging systems |
| Abstract: | Purpose: To develop a B0$$ {B}_0 $$ self‐navigation approach to estimate respiratory motion for motion‐corrected liver T1$$ {T}_1 $$ mapping using a Look‐Locker acquisition with radial stack‐of‐stars trajectory. Methods: The proposed method derives 1D field‐map profiles from the oversampled k‐space center to estimate a normalized breathing curve and the B0$$ {B}_0 $$ variation amplitude for each slice and coil. B0$$ {B}_0 $$ drift and contrast variations, inherent to the Look‐Locker acquisition, were modeled and corrected by fitting and demodulating drift and offset terms. The breathing curve was employed to bin data into motion states for motion‐resolved reconstruction, followed by water‐specific T1$$ {T}_1 $$ mapping. Simulations with an anatomical body model and in vivo experiments with a Look‐Locker multi‐echo gradient echo sequence were performed to validate the technique. The estimated normalized breathing curve was compared with magnitude‐ and phase‐based self‐navigation approaches using principal component analysis. Results: The proposed B0$$ {B}_0 $$ self‐navigation reliably estimated the normalized breathing curve and the B0$$ {B}_0 $$ variation amplitude in simulations and in vivo. B0$$ {B}_0 $$ variation amplitudes increased with greater tissue displacement, with median values across slices and coils ranging from 4 to 15 Hz at 3 T in volunteers. Motion‐resolved reconstruction using the estimated breathing curve reduced motion artifacts and improved image and T1$$ {T}_1 $$ mapping quality compared to motion‐averaged reconstruction. Conclusion: B0$$ {B}_0 $$ self‐navigation allows estimation of respiratory motion in acquisitions with varying contrast and quantifies the B0$$ {B}_0 $$ variation amplitude, providing a possible surrogate signal for tissue displacement and enabling self‐gated liver T1$$ {T}_1 $$ mapping using a Look‐Locker approach. [ABSTRACT FROM AUTHOR] |
| Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 188365640 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: B<subscript>0</subscript> navigator enables respiratory motion navigation in radial stack‐of‐stars liver Look‐Locker T<subscript>1</subscript> mapping. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Stelter%2C+Jonathan%22">Stelter, Jonathan</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> jonathan.stelter@tum.de</i><br /><searchLink fieldCode="AR" term="%22Weiss%2C+Kilian%22">Weiss, Kilian</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Spieker%2C+Veronika%22">Spieker, Veronika</searchLink><relatesTo>3,4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Schnabel%2C+Julia+A%2E%22">Schnabel, Julia A.</searchLink><relatesTo>3,4,5</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Braren%2C+Rickmer+F%2E%22">Braren, Rickmer F.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Karampinos%2C+Dimitrios+C%2E%22">Karampinos, Dimitrios C.</searchLink><relatesTo>1,6,7</relatesTo> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Magnetic+Resonance+in+Medicine%22">Magnetic Resonance in Medicine</searchLink>. Oct2025, Vol. 94 Issue 4, p1458-1468. 11p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Respiratory+mechanics%22">Respiratory mechanics</searchLink><br /><searchLink fieldCode="DE" term="%22Motion+compensation+%28Signal+processing%29%22">Motion compensation (Signal processing)</searchLink><br /><searchLink fieldCode="DE" term="%22Computer-assisted+image+analysis+%28Medicine%29%22">Computer-assisted image analysis (Medicine)</searchLink><br /><searchLink fieldCode="DE" term="%22Automatic+tracking%22">Automatic tracking</searchLink><br /><searchLink fieldCode="DE" term="%22Diagnostic+imaging%22">Diagnostic imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Magnetic+resonance+imaging%22">Magnetic resonance imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Image+quality+in+imaging+systems%22">Image quality in imaging systems</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Purpose: To develop a B0$$ {B}_0 $$ self‐navigation approach to estimate respiratory motion for motion‐corrected liver T1$$ {T}_1 $$ mapping using a Look‐Locker acquisition with radial stack‐of‐stars trajectory. Methods: The proposed method derives 1D field‐map profiles from the oversampled k‐space center to estimate a normalized breathing curve and the B0$$ {B}_0 $$ variation amplitude for each slice and coil. B0$$ {B}_0 $$ drift and contrast variations, inherent to the Look‐Locker acquisition, were modeled and corrected by fitting and demodulating drift and offset terms. The breathing curve was employed to bin data into motion states for motion‐resolved reconstruction, followed by water‐specific T1$$ {T}_1 $$ mapping. Simulations with an anatomical body model and in vivo experiments with a Look‐Locker multi‐echo gradient echo sequence were performed to validate the technique. The estimated normalized breathing curve was compared with magnitude‐ and phase‐based self‐navigation approaches using principal component analysis. Results: The proposed B0$$ {B}_0 $$ self‐navigation reliably estimated the normalized breathing curve and the B0$$ {B}_0 $$ variation amplitude in simulations and in vivo. B0$$ {B}_0 $$ variation amplitudes increased with greater tissue displacement, with median values across slices and coils ranging from 4 to 15 Hz at 3 T in volunteers. Motion‐resolved reconstruction using the estimated breathing curve reduced motion artifacts and improved image and T1$$ {T}_1 $$ mapping quality compared to motion‐averaged reconstruction. Conclusion: B0$$ {B}_0 $$ self‐navigation allows estimation of respiratory motion in acquisitions with varying contrast and quantifies the B0$$ {B}_0 $$ variation amplitude, providing a possible surrogate signal for tissue displacement and enabling self‐gated liver T1$$ {T}_1 $$ mapping using a Look‐Locker approach. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=188365640 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1002/mrm.30567 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 11 StartPage: 1458 Subjects: – SubjectFull: Respiratory mechanics Type: general – SubjectFull: Motion compensation (Signal processing) Type: general – SubjectFull: Computer-assisted image analysis (Medicine) Type: general – SubjectFull: Automatic tracking Type: general – SubjectFull: Diagnostic imaging Type: general – SubjectFull: Magnetic resonance imaging Type: general – SubjectFull: Image quality in imaging systems Type: general Titles: – TitleFull: B0 navigator enables respiratory motion navigation in radial stack‐of‐stars liver Look‐Locker T1 mapping. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Stelter, Jonathan – PersonEntity: Name: NameFull: Weiss, Kilian – PersonEntity: Name: NameFull: Spieker, Veronika – PersonEntity: Name: NameFull: Schnabel, Julia A. – PersonEntity: Name: NameFull: Braren, Rickmer F. – PersonEntity: Name: NameFull: Karampinos, Dimitrios C. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 10 Text: Oct2025 Type: published Y: 2025 Identifiers: – Type: issn-print Value: 07403194 Numbering: – Type: volume Value: 94 – Type: issue Value: 4 Titles: – TitleFull: Magnetic Resonance in Medicine Type: main |
| ResultId | 1 |