MRI of wrist ligament trauma was similar at 7 T and 3 T with arthroscopy as a reference standard.
Saved in:
| Title: | MRI of wrist ligament trauma was similar at 7 T and 3 T with arthroscopy as a reference standard. |
|---|---|
| Authors: | Götestrand, Simon1,2 (AUTHOR) simon.gotestrand@med.lu.se, Flondell, Magnus3,4 (AUTHOR), Lundin, Björn1,2 (AUTHOR), Aksyuk, Elena2 (AUTHOR), Shalhoub, Rami Abu2 (AUTHOR), Szaro, Pawel5,6 (AUTHOR), Hedström, Erik1,2,7,8 (AUTHOR), Björkman, Anders4,9,10 (AUTHOR), Geijer, Mats1,5,6 (AUTHOR) |
| Source: | European Radiology. Nov2025, Vol. 35 Issue 11, p6949-6957. 9p. |
| Subjects: | Magnetic resonance imaging, Ligament injuries, Arthroscopy, Wrist |
| Abstract: | Objectives: The aim was to compare the diagnostic accuracy of magnetic resonance imaging (MRI) at 7 Tesla (T) and 3 T in patients with clinically suspected injury of the triangular fibrocartilage complex (TFCC) or the scapholunate ligament (SLL) using wrist arthroscopy as a reference standard. Methods: Twenty-four patients scheduled for wrist arthroscopy due to suspected TFCC or SLL injury were examined with 7-T and 3-T MRI before arthroscopy. Four musculoskeletal radiologists independently evaluated the MR examinations in randomized order, and the findings were compared to those at wrist arthroscopy. Results: Sensitivity, specificity, and accuracy for TFCC injuries were 0.85, 0.68, and 0.82 for 7 T and 0.75, 0.73, and 0.77 for 3 T, respectively. For SLL injuries, the corresponding values were 0.70, 0.65, and 0.74 for 7 T and 0.69, 0.55, and 0.70 for 3 T, respectively. For both TFCC and SLL injuries, no statistically significant difference between 7 T and 3 T was found, and the confidence intervals for accuracy overlapped (0.67–0.94 vs 0.63–0.88 for TFCC injuries and 0.59–0.89 vs 0.52–0.86 for SLL injuries). In 14 of 24 patients (58%), MRI contributed findings of additional types of injuries, e.g., tendon injuries and ganglia, vital for a complete diagnosis. Conclusions: The diagnostic accuracy of MRI at 7 T was similar to 3 T for detecting injury to the TFCC and the SLL. A majority of injuries were correctly diagnosed by MRI, but some injuries found using arthroscopy were missed. Key Points: QuestionPrevious studies have found that MRI cannot reliably diagnose or rule out TFCC or SLL injury, compared to the current reference standard wrist arthroscopy. FindingsThe diagnostic accuracy for MRI at 7 T was similar to 3 T for detecting injuries to the TFCC and the SLL. Clinical relevanceAlthough MRI cannot replace wrist arthroscopy, it is an important complementary tool in the diagnostic workup of suspected wrist ligament injuries, with the ability to diagnose additional types of pathologies not accessible by arthroscopy. [ABSTRACT FROM AUTHOR] |
| Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 188901882 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: MRI of wrist ligament trauma was similar at 7 T and 3 T with arthroscopy as a reference standard. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Götestrand%2C+Simon%22">Götestrand, Simon</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<i> simon.gotestrand@med.lu.se</i><br /><searchLink fieldCode="AR" term="%22Flondell%2C+Magnus%22">Flondell, Magnus</searchLink><relatesTo>3,4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Lundin%2C+Björn%22">Lundin, Björn</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Aksyuk%2C+Elena%22">Aksyuk, Elena</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Shalhoub%2C+Rami+Abu%22">Shalhoub, Rami Abu</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Szaro%2C+Pawel%22">Szaro, Pawel</searchLink><relatesTo>5,6</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Hedström%2C+Erik%22">Hedström, Erik</searchLink><relatesTo>1,2,7,8</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Björkman%2C+Anders%22">Björkman, Anders</searchLink><relatesTo>4,9,10</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Geijer%2C+Mats%22">Geijer, Mats</searchLink><relatesTo>1,5,6</relatesTo> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22European+Radiology%22">European Radiology</searchLink>. Nov2025, Vol. 35 Issue 11, p6949-6957. 9p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Magnetic+resonance+imaging%22">Magnetic resonance imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Ligament+injuries%22">Ligament injuries</searchLink><br /><searchLink fieldCode="DE" term="%22Arthroscopy%22">Arthroscopy</searchLink><br /><searchLink fieldCode="DE" term="%22Wrist%22">Wrist</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Objectives: The aim was to compare the diagnostic accuracy of magnetic resonance imaging (MRI) at 7 Tesla (T) and 3 T in patients with clinically suspected injury of the triangular fibrocartilage complex (TFCC) or the scapholunate ligament (SLL) using wrist arthroscopy as a reference standard. Methods: Twenty-four patients scheduled for wrist arthroscopy due to suspected TFCC or SLL injury were examined with 7-T and 3-T MRI before arthroscopy. Four musculoskeletal radiologists independently evaluated the MR examinations in randomized order, and the findings were compared to those at wrist arthroscopy. Results: Sensitivity, specificity, and accuracy for TFCC injuries were 0.85, 0.68, and 0.82 for 7 T and 0.75, 0.73, and 0.77 for 3 T, respectively. For SLL injuries, the corresponding values were 0.70, 0.65, and 0.74 for 7 T and 0.69, 0.55, and 0.70 for 3 T, respectively. For both TFCC and SLL injuries, no statistically significant difference between 7 T and 3 T was found, and the confidence intervals for accuracy overlapped (0.67–0.94 vs 0.63–0.88 for TFCC injuries and 0.59–0.89 vs 0.52–0.86 for SLL injuries). In 14 of 24 patients (58%), MRI contributed findings of additional types of injuries, e.g., tendon injuries and ganglia, vital for a complete diagnosis. Conclusions: The diagnostic accuracy of MRI at 7 T was similar to 3 T for detecting injury to the TFCC and the SLL. A majority of injuries were correctly diagnosed by MRI, but some injuries found using arthroscopy were missed. Key Points: QuestionPrevious studies have found that MRI cannot reliably diagnose or rule out TFCC or SLL injury, compared to the current reference standard wrist arthroscopy. FindingsThe diagnostic accuracy for MRI at 7 T was similar to 3 T for detecting injuries to the TFCC and the SLL. Clinical relevanceAlthough MRI cannot replace wrist arthroscopy, it is an important complementary tool in the diagnostic workup of suspected wrist ligament injuries, with the ability to diagnose additional types of pathologies not accessible by arthroscopy. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=188901882 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1007/s00330-025-11656-4 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 9 StartPage: 6949 Subjects: – SubjectFull: Magnetic resonance imaging Type: general – SubjectFull: Ligament injuries Type: general – SubjectFull: Arthroscopy Type: general – SubjectFull: Wrist Type: general Titles: – TitleFull: MRI of wrist ligament trauma was similar at 7 T and 3 T with arthroscopy as a reference standard. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Götestrand, Simon – PersonEntity: Name: NameFull: Flondell, Magnus – PersonEntity: Name: NameFull: Lundin, Björn – PersonEntity: Name: NameFull: Aksyuk, Elena – PersonEntity: Name: NameFull: Shalhoub, Rami Abu – PersonEntity: Name: NameFull: Szaro, Pawel – PersonEntity: Name: NameFull: Hedström, Erik – PersonEntity: Name: NameFull: Björkman, Anders – PersonEntity: Name: NameFull: Geijer, Mats IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 11 Text: Nov2025 Type: published Y: 2025 Identifiers: – Type: issn-print Value: 09387994 Numbering: – Type: volume Value: 35 – Type: issue Value: 11 Titles: – TitleFull: European Radiology Type: main |
| ResultId | 1 |