MRI of wrist ligament trauma was similar at 7 T and 3 T with arthroscopy as a reference standard.

Saved in:
Bibliographic Details
Title: MRI of wrist ligament trauma was similar at 7 T and 3 T with arthroscopy as a reference standard.
Authors: Götestrand, Simon1,2 (AUTHOR) simon.gotestrand@med.lu.se, Flondell, Magnus3,4 (AUTHOR), Lundin, Björn1,2 (AUTHOR), Aksyuk, Elena2 (AUTHOR), Shalhoub, Rami Abu2 (AUTHOR), Szaro, Pawel5,6 (AUTHOR), Hedström, Erik1,2,7,8 (AUTHOR), Björkman, Anders4,9,10 (AUTHOR), Geijer, Mats1,5,6 (AUTHOR)
Source: European Radiology. Nov2025, Vol. 35 Issue 11, p6949-6957. 9p.
Subjects: Magnetic resonance imaging, Ligament injuries, Arthroscopy, Wrist
Abstract: Objectives: The aim was to compare the diagnostic accuracy of magnetic resonance imaging (MRI) at 7 Tesla (T) and 3 T in patients with clinically suspected injury of the triangular fibrocartilage complex (TFCC) or the scapholunate ligament (SLL) using wrist arthroscopy as a reference standard. Methods: Twenty-four patients scheduled for wrist arthroscopy due to suspected TFCC or SLL injury were examined with 7-T and 3-T MRI before arthroscopy. Four musculoskeletal radiologists independently evaluated the MR examinations in randomized order, and the findings were compared to those at wrist arthroscopy. Results: Sensitivity, specificity, and accuracy for TFCC injuries were 0.85, 0.68, and 0.82 for 7 T and 0.75, 0.73, and 0.77 for 3 T, respectively. For SLL injuries, the corresponding values were 0.70, 0.65, and 0.74 for 7 T and 0.69, 0.55, and 0.70 for 3 T, respectively. For both TFCC and SLL injuries, no statistically significant difference between 7 T and 3 T was found, and the confidence intervals for accuracy overlapped (0.67–0.94 vs 0.63–0.88 for TFCC injuries and 0.59–0.89 vs 0.52–0.86 for SLL injuries). In 14 of 24 patients (58%), MRI contributed findings of additional types of injuries, e.g., tendon injuries and ganglia, vital for a complete diagnosis. Conclusions: The diagnostic accuracy of MRI at 7 T was similar to 3 T for detecting injury to the TFCC and the SLL. A majority of injuries were correctly diagnosed by MRI, but some injuries found using arthroscopy were missed. Key Points: QuestionPrevious studies have found that MRI cannot reliably diagnose or rule out TFCC or SLL injury, compared to the current reference standard wrist arthroscopy. FindingsThe diagnostic accuracy for MRI at 7 T was similar to 3 T for detecting injuries to the TFCC and the SLL. Clinical relevanceAlthough MRI cannot replace wrist arthroscopy, it is an important complementary tool in the diagnostic workup of suspected wrist ligament injuries, with the ability to diagnose additional types of pathologies not accessible by arthroscopy. [ABSTRACT FROM AUTHOR]
Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 188901882
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: MRI of wrist ligament trauma was similar at 7 T and 3 T with arthroscopy as a reference standard.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Götestrand%2C+Simon%22">Götestrand, Simon</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<i> simon.gotestrand@med.lu.se</i><br /><searchLink fieldCode="AR" term="%22Flondell%2C+Magnus%22">Flondell, Magnus</searchLink><relatesTo>3,4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Lundin%2C+Björn%22">Lundin, Björn</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Aksyuk%2C+Elena%22">Aksyuk, Elena</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Shalhoub%2C+Rami+Abu%22">Shalhoub, Rami Abu</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Szaro%2C+Pawel%22">Szaro, Pawel</searchLink><relatesTo>5,6</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Hedström%2C+Erik%22">Hedström, Erik</searchLink><relatesTo>1,2,7,8</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Björkman%2C+Anders%22">Björkman, Anders</searchLink><relatesTo>4,9,10</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Geijer%2C+Mats%22">Geijer, Mats</searchLink><relatesTo>1,5,6</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22European+Radiology%22">European Radiology</searchLink>. Nov2025, Vol. 35 Issue 11, p6949-6957. 9p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Magnetic+resonance+imaging%22">Magnetic resonance imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Ligament+injuries%22">Ligament injuries</searchLink><br /><searchLink fieldCode="DE" term="%22Arthroscopy%22">Arthroscopy</searchLink><br /><searchLink fieldCode="DE" term="%22Wrist%22">Wrist</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Objectives: The aim was to compare the diagnostic accuracy of magnetic resonance imaging (MRI) at 7 Tesla (T) and 3 T in patients with clinically suspected injury of the triangular fibrocartilage complex (TFCC) or the scapholunate ligament (SLL) using wrist arthroscopy as a reference standard. Methods: Twenty-four patients scheduled for wrist arthroscopy due to suspected TFCC or SLL injury were examined with 7-T and 3-T MRI before arthroscopy. Four musculoskeletal radiologists independently evaluated the MR examinations in randomized order, and the findings were compared to those at wrist arthroscopy. Results: Sensitivity, specificity, and accuracy for TFCC injuries were 0.85, 0.68, and 0.82 for 7 T and 0.75, 0.73, and 0.77 for 3 T, respectively. For SLL injuries, the corresponding values were 0.70, 0.65, and 0.74 for 7 T and 0.69, 0.55, and 0.70 for 3 T, respectively. For both TFCC and SLL injuries, no statistically significant difference between 7 T and 3 T was found, and the confidence intervals for accuracy overlapped (0.67–0.94 vs 0.63–0.88 for TFCC injuries and 0.59–0.89 vs 0.52–0.86 for SLL injuries). In 14 of 24 patients (58%), MRI contributed findings of additional types of injuries, e.g., tendon injuries and ganglia, vital for a complete diagnosis. Conclusions: The diagnostic accuracy of MRI at 7 T was similar to 3 T for detecting injury to the TFCC and the SLL. A majority of injuries were correctly diagnosed by MRI, but some injuries found using arthroscopy were missed. Key Points: QuestionPrevious studies have found that MRI cannot reliably diagnose or rule out TFCC or SLL injury, compared to the current reference standard wrist arthroscopy. FindingsThe diagnostic accuracy for MRI at 7 T was similar to 3 T for detecting injuries to the TFCC and the SLL. Clinical relevanceAlthough MRI cannot replace wrist arthroscopy, it is an important complementary tool in the diagnostic workup of suspected wrist ligament injuries, with the ability to diagnose additional types of pathologies not accessible by arthroscopy. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=188901882
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s00330-025-11656-4
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 9
        StartPage: 6949
    Subjects:
      – SubjectFull: Magnetic resonance imaging
        Type: general
      – SubjectFull: Ligament injuries
        Type: general
      – SubjectFull: Arthroscopy
        Type: general
      – SubjectFull: Wrist
        Type: general
    Titles:
      – TitleFull: MRI of wrist ligament trauma was similar at 7 T and 3 T with arthroscopy as a reference standard.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Götestrand, Simon
      – PersonEntity:
          Name:
            NameFull: Flondell, Magnus
      – PersonEntity:
          Name:
            NameFull: Lundin, Björn
      – PersonEntity:
          Name:
            NameFull: Aksyuk, Elena
      – PersonEntity:
          Name:
            NameFull: Shalhoub, Rami Abu
      – PersonEntity:
          Name:
            NameFull: Szaro, Pawel
      – PersonEntity:
          Name:
            NameFull: Hedström, Erik
      – PersonEntity:
          Name:
            NameFull: Björkman, Anders
      – PersonEntity:
          Name:
            NameFull: Geijer, Mats
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 11
              Text: Nov2025
              Type: published
              Y: 2025
          Identifiers:
            – Type: issn-print
              Value: 09387994
          Numbering:
            – Type: volume
              Value: 35
            – Type: issue
              Value: 11
          Titles:
            – TitleFull: European Radiology
              Type: main
ResultId 1