Title: AI in motion: the impact of data augmentation strategies on mitigating MRI motion artifacts.
Authors: Westfechtel, Simon D.1 (AUTHOR) swestfechtel@ukaachen.de, Kußmann, Kristoffer1 (AUTHOR), Aßmann, Cederic1 (AUTHOR), Huppertz, Marc S.1 (AUTHOR), Siepmann, Robert M.1 (AUTHOR), Lemainque, Teresa1 (AUTHOR), Winter, Vera R.1 (AUTHOR), Barabasch, Alexandra1 (AUTHOR), Kuhl, Christiane K.1 (AUTHOR), Truhn, Daniel1 (AUTHOR), Nebelung, Sven1 (AUTHOR)
Source: European Radiology. Nov2025, Vol. 35 Issue 11, p6865-6878. 14p.
Subjects: Magnetic resonance imaging, Data augmentation, Artificial intelligence
Abstract: Objectives: Artifacts in clinical MRI can compromise the performance of AI models. This study evaluates how different data augmentation strategies affect an AI model's segmentation performance under variable artifact severity. Materials and methods: We used an AI model based on the nnU-Net architecture to automatically quantify lower limb alignment using axial T2-weighted MR images. Three versions of the AI model were trained with different augmentation strategies: (1) no augmentation ("baseline"), (2) standard nnU-net augmentations ("default"), and (3) "default" plus augmentations that emulate MR artifacts ("MRI-specific"). Model performance was tested on 600 MR image stacks (right and left; hip, knee, and ankle) from 20 healthy participants (mean age, 23 ± 3 years, 17 men), each imaged five times under standardized motion to induce artifacts. Two radiologists graded each stack's artifact severity as none, mild, moderate, and severe, and manually measured torsional angles. Segmentation quality was assessed using the Dice similarity coefficient (DSC), while torsional angles were compared between manual and automatic measurements using mean absolute deviation (MAD), intraclass correlation coefficient (ICC), and Pearson's correlation coefficient (r). Statistical analysis included parametric tests and a Linear Mixed-Effects Model. Results: MRI-specific augmentation resulted in slightly (yet not significantly) better performance than the default strategy. Segmentation quality decreased with increasing artifact severity, which was partially mitigated by default and MRI-specific augmentations (e.g., severe artifacts, proximal femur: DSCbaseline = 0.58 ± 0.22; DSCdefault = 0.72 ± 0.22; DSCMRI-specific = 0.79 ± 0.14 [p < 0.001]). These augmentations also maintained precise torsional angle measurements (e.g., severe artifacts, femoral torsion: MADbaseline = 20.6 ± 23.5°; MADdefault = 7.0 ± 13.0°; MADMRI-specific = 5.7 ± 9.5° [p < 0.001]; ICCbaseline = −0.10 [p = 0.63; 95% CI: −0.61 to 0.47]; ICCdefault = 0.38 [p = 0.08; −0.17 to 0.76]; ICCMRI-specific = 0.86 [p < 0.001; 0.62 to 0.95]; rbaseline = 0.58 [p < 0.001; 0.44 to 0.69]; rdefault = 0.68 [p < 0.001; 0.56 to 0.77]; rMRI-specific = 0.86 [p < 0.001; 0.81 to 0.9]). Conclusion: Motion artifacts negatively impact AI models, but general-purpose augmentations enhance robustness effectively. MRI-specific augmentations offer minimal additional benefit. Key Points: QuestionMotion artifacts negatively impact the performance of diagnostic AI models for MRI, but mitigation methods remain largely unexplored. FindingsDomain-specific augmentation during training can improve the robustness and performance of a model for quantifying lower limb alignment in the presence of severe artifacts. Clinical relevanceExcellent robustness and accuracy are crucial for deploying diagnostic AI models in clinical practice. Including domain knowledge in model training can benefit clinical adoption. [ABSTRACT FROM AUTHOR]
Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 188901893
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: AI in motion: the impact of data augmentation strategies on mitigating MRI motion artifacts.
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Westfechtel%2C+Simon+D%2E%22&quot;&gt;Westfechtel, Simon D.&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;i&gt; swestfechtel@ukaachen.de&lt;/i&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Ku&#223;mann%2C+Kristoffer%22&quot;&gt;Ku&#223;mann, Kristoffer&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22A&#223;mann%2C+Cederic%22&quot;&gt;A&#223;mann, Cederic&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Huppertz%2C+Marc+S%2E%22&quot;&gt;Huppertz, Marc S.&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Siepmann%2C+Robert+M%2E%22&quot;&gt;Siepmann, Robert M.&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Lemainque%2C+Teresa%22&quot;&gt;Lemainque, Teresa&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Winter%2C+Vera+R%2E%22&quot;&gt;Winter, Vera R.&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Barabasch%2C+Alexandra%22&quot;&gt;Barabasch, Alexandra&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Kuhl%2C+Christiane+K%2E%22&quot;&gt;Kuhl, Christiane K.&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Truhn%2C+Daniel%22&quot;&gt;Truhn, Daniel&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Nebelung%2C+Sven%22&quot;&gt;Nebelung, Sven&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%22European+Radiology%22&quot;&gt;European Radiology&lt;/searchLink&gt;. Nov2025, Vol. 35 Issue 11, p6865-6878. 14p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Magnetic+resonance+imaging%22&quot;&gt;Magnetic resonance imaging&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Data+augmentation%22&quot;&gt;Data augmentation&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Artificial+intelligence%22&quot;&gt;Artificial intelligence&lt;/searchLink&gt;
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Objectives: Artifacts in clinical MRI can compromise the performance of AI models. This study evaluates how different data augmentation strategies affect an AI model&#39;s segmentation performance under variable artifact severity. Materials and methods: We used an AI model based on the nnU-Net architecture to automatically quantify lower limb alignment using axial T2-weighted MR images. Three versions of the AI model were trained with different augmentation strategies: (1) no augmentation (&quot;baseline&quot;), (2) standard nnU-net augmentations (&quot;default&quot;), and (3) &quot;default&quot; plus augmentations that emulate MR artifacts (&quot;MRI-specific&quot;). Model performance was tested on 600 MR image stacks (right and left; hip, knee, and ankle) from 20 healthy participants (mean age, 23 &#177; 3 years, 17 men), each imaged five times under standardized motion to induce artifacts. Two radiologists graded each stack&#39;s artifact severity as none, mild, moderate, and severe, and manually measured torsional angles. Segmentation quality was assessed using the Dice similarity coefficient (DSC), while torsional angles were compared between manual and automatic measurements using mean absolute deviation (MAD), intraclass correlation coefficient (ICC), and Pearson&#39;s correlation coefficient (r). Statistical analysis included parametric tests and a Linear Mixed-Effects Model. Results: MRI-specific augmentation resulted in slightly (yet not significantly) better performance than the default strategy. Segmentation quality decreased with increasing artifact severity, which was partially mitigated by default and MRI-specific augmentations (e.g., severe artifacts, proximal femur: DSCbaseline = 0.58 &#177; 0.22; DSCdefault = 0.72 &#177; 0.22; DSCMRI-specific = 0.79 &#177; 0.14 [p &lt; 0.001]). These augmentations also maintained precise torsional angle measurements (e.g., severe artifacts, femoral torsion: MADbaseline = 20.6 &#177; 23.5&#176;; MADdefault = 7.0 &#177; 13.0&#176;; MADMRI-specific = 5.7 &#177; 9.5&#176; [p &lt; 0.001]; ICCbaseline = −0.10 [p = 0.63; 95% CI: −0.61 to 0.47]; ICCdefault = 0.38 [p = 0.08; −0.17 to 0.76]; ICCMRI-specific = 0.86 [p &lt; 0.001; 0.62 to 0.95]; rbaseline = 0.58 [p &lt; 0.001; 0.44 to 0.69]; rdefault = 0.68 [p &lt; 0.001; 0.56 to 0.77]; rMRI-specific = 0.86 [p &lt; 0.001; 0.81 to 0.9]). Conclusion: Motion artifacts negatively impact AI models, but general-purpose augmentations enhance robustness effectively. MRI-specific augmentations offer minimal additional benefit. Key Points: QuestionMotion artifacts negatively impact the performance of diagnostic AI models for MRI, but mitigation methods remain largely unexplored. FindingsDomain-specific augmentation during training can improve the robustness and performance of a model for quantifying lower limb alignment in the presence of severe artifacts. Clinical relevanceExcellent robustness and accuracy are crucial for deploying diagnostic AI models in clinical practice. Including domain knowledge in model training can benefit clinical adoption. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: &lt;i&gt;Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder&#39;s express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.&lt;/i&gt; (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=188901893
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s00330-025-11670-6
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 14
        StartPage: 6865
    Subjects:
      – SubjectFull: Magnetic resonance imaging
        Type: general
      – SubjectFull: Data augmentation
        Type: general
      – SubjectFull: Artificial intelligence
        Type: general
    Titles:
      – TitleFull: AI in motion: the impact of data augmentation strategies on mitigating MRI motion artifacts.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Westfechtel, Simon D.
      – PersonEntity:
          Name:
            NameFull: Kußmann, Kristoffer
      – PersonEntity:
          Name:
            NameFull: Aßmann, Cederic
      – PersonEntity:
          Name:
            NameFull: Huppertz, Marc S.
      – PersonEntity:
          Name:
            NameFull: Siepmann, Robert M.
      – PersonEntity:
          Name:
            NameFull: Lemainque, Teresa
      – PersonEntity:
          Name:
            NameFull: Winter, Vera R.
      – PersonEntity:
          Name:
            NameFull: Barabasch, Alexandra
      – PersonEntity:
          Name:
            NameFull: Kuhl, Christiane K.
      – PersonEntity:
          Name:
            NameFull: Truhn, Daniel
      – PersonEntity:
          Name:
            NameFull: Nebelung, Sven
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 11
              Text: Nov2025
              Type: published
              Y: 2025
          Identifiers:
            – Type: issn-print
              Value: 09387994
          Numbering:
            – Type: volume
              Value: 35
            – Type: issue
              Value: 11
          Titles:
            – TitleFull: European Radiology
              Type: main
ResultId 1