Reply to the Letter to the Editor: Dual-energy CT in acute mesenteric ischemia: going beyond diagnostic confidence improvement.

Saved in:
Bibliographic Details
Title: Reply to the Letter to the Editor: Dual-energy CT in acute mesenteric ischemia: going beyond diagnostic confidence improvement.
Authors: Oberparleiter, Moritz1 (AUTHOR), Breit, Hanns-Christian1 (AUTHOR), Obmann, Markus M.1 (AUTHOR) markus.obmann@gmail.com
Source: European Radiology. Dec2025, Vol. 35 Issue 12, p8263-8265. 3p.
Subjects: Dual energy CT (Tomography), Mesenteric ischemia, Experimental design, Diagnosis, Computed tomography, Iodine isotopes, Diagnostic imaging, Medical practice
Abstract: The article discusses the response to a commentary on a study evaluating the diagnostic performance of dual-energy computed tomography (DECT) for acute bowel ischemia. The authors emphasize that their study was designed to reflect everyday clinical practice, allowing readers to assess imaging features without a strict diagnostic algorithm. They address concerns about the study's methodology, including the use of surgical reports as a reference standard and the subjective nature of self-reported diagnostic confidence. The authors advocate for future research to focus on advanced outcome parameters and the potential of quantitative iodine measurements in improving diagnostic accuracy for acute bowel ischemia. [Extracted from the article]
Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 189534029
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Reply to the Letter to the Editor: Dual-energy CT in acute mesenteric ischemia: going beyond diagnostic confidence improvement.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Oberparleiter%2C+Moritz%22">Oberparleiter, Moritz</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Breit%2C+Hanns-Christian%22">Breit, Hanns-Christian</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Obmann%2C+Markus+M%2E%22">Obmann, Markus M.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> markus.obmann@gmail.com</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22European+Radiology%22">European Radiology</searchLink>. Dec2025, Vol. 35 Issue 12, p8263-8265. 3p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Dual+energy+CT+%28Tomography%29%22">Dual energy CT (Tomography)</searchLink><br /><searchLink fieldCode="DE" term="%22Mesenteric+ischemia%22">Mesenteric ischemia</searchLink><br /><searchLink fieldCode="DE" term="%22Experimental+design%22">Experimental design</searchLink><br /><searchLink fieldCode="DE" term="%22Diagnosis%22">Diagnosis</searchLink><br /><searchLink fieldCode="DE" term="%22Computed+tomography%22">Computed tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Iodine+isotopes%22">Iodine isotopes</searchLink><br /><searchLink fieldCode="DE" term="%22Diagnostic+imaging%22">Diagnostic imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+practice%22">Medical practice</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: The article discusses the response to a commentary on a study evaluating the diagnostic performance of dual-energy computed tomography (DECT) for acute bowel ischemia. The authors emphasize that their study was designed to reflect everyday clinical practice, allowing readers to assess imaging features without a strict diagnostic algorithm. They address concerns about the study's methodology, including the use of surgical reports as a reference standard and the subjective nature of self-reported diagnostic confidence. The authors advocate for future research to focus on advanced outcome parameters and the potential of quantitative iodine measurements in improving diagnostic accuracy for acute bowel ischemia. [Extracted from the article]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=189534029
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s00330-025-11628-8
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 3
        StartPage: 8263
    Subjects:
      – SubjectFull: Dual energy CT (Tomography)
        Type: general
      – SubjectFull: Mesenteric ischemia
        Type: general
      – SubjectFull: Experimental design
        Type: general
      – SubjectFull: Diagnosis
        Type: general
      – SubjectFull: Computed tomography
        Type: general
      – SubjectFull: Iodine isotopes
        Type: general
      – SubjectFull: Diagnostic imaging
        Type: general
      – SubjectFull: Medical practice
        Type: general
    Titles:
      – TitleFull: Reply to the Letter to the Editor: Dual-energy CT in acute mesenteric ischemia: going beyond diagnostic confidence improvement.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Oberparleiter, Moritz
      – PersonEntity:
          Name:
            NameFull: Breit, Hanns-Christian
      – PersonEntity:
          Name:
            NameFull: Obmann, Markus M.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 12
              Text: Dec2025
              Type: published
              Y: 2025
          Identifiers:
            – Type: issn-print
              Value: 09387994
          Numbering:
            – Type: volume
              Value: 35
            – Type: issue
              Value: 12
          Titles:
            – TitleFull: European Radiology
              Type: main
ResultId 1