EXPERIMENTAL MEASUREMENTS AT THE STEAM GENERATOR OF THE 330 MW POWER PLANT.

Saved in:
Bibliographic Details
Title: EXPERIMENTAL MEASUREMENTS AT THE STEAM GENERATOR OF THE 330 MW POWER PLANT.
Authors: Racoceanu, Cristinel1
Source: Annals of 'Constantin Brancusi' University of Targu-Jiu. Engineering Series / Analele Universităţii Constantin Brâncuşi din Târgu-Jiu. Seria Inginerie. 2025, Issue 3, p118-123. 6p.
Subjects: Steam generators, Coal-fired power plants, Coal, Empirical research, Natural gas, Thermoelectricity, Flame stability
Abstract: This paper presents a case study on experimental measurements performed on the steam generator of power unit no. 5 at the Rovinari thermoelectric power plant. The 1035 t/h Benson steam generator operates with coal, and natural gas is used for ignition and flame stability. [ABSTRACT FROM AUTHOR]
Copyright of Annals of 'Constantin Brancusi' University of Targu-Jiu. Engineering Series / Analele Universităţii Constantin Brâncuşi din Târgu-Jiu. Seria Inginerie is the property of Universitatea Constantin Brancusi din Targu-Jiu and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 189896407
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: EXPERIMENTAL MEASUREMENTS AT THE STEAM GENERATOR OF THE 330 MW POWER PLANT.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Racoceanu%2C+Cristinel%22">Racoceanu, Cristinel</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Annals+of+'Constantin+Brancusi'+University+of+Targu-Jiu%2E+Engineering+Series+%2F+Analele+Universităţii+Constantin+Brâncuşi+din+Târgu-Jiu%2E+Seria+Inginerie%22">Annals of 'Constantin Brancusi' University of Targu-Jiu. Engineering Series / Analele Universităţii Constantin Brâncuşi din Târgu-Jiu. Seria Inginerie</searchLink>. 2025, Issue 3, p118-123. 6p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Steam+generators%22">Steam generators</searchLink><br /><searchLink fieldCode="DE" term="%22Coal-fired+power+plants%22">Coal-fired power plants</searchLink><br /><searchLink fieldCode="DE" term="%22Coal%22">Coal</searchLink><br /><searchLink fieldCode="DE" term="%22Empirical+research%22">Empirical research</searchLink><br /><searchLink fieldCode="DE" term="%22Natural+gas%22">Natural gas</searchLink><br /><searchLink fieldCode="DE" term="%22Thermoelectricity%22">Thermoelectricity</searchLink><br /><searchLink fieldCode="DE" term="%22Flame+stability%22">Flame stability</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: This paper presents a case study on experimental measurements performed on the steam generator of power unit no. 5 at the Rovinari thermoelectric power plant. The 1035 t/h Benson steam generator operates with coal, and natural gas is used for ignition and flame stability. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Annals of 'Constantin Brancusi' University of Targu-Jiu. Engineering Series / Analele Universităţii Constantin Brâncuşi din Târgu-Jiu. Seria Inginerie is the property of Universitatea Constantin Brancusi din Targu-Jiu and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=189896407
RecordInfo BibRecord:
  BibEntity:
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 6
        StartPage: 118
    Subjects:
      – SubjectFull: Steam generators
        Type: general
      – SubjectFull: Coal-fired power plants
        Type: general
      – SubjectFull: Coal
        Type: general
      – SubjectFull: Empirical research
        Type: general
      – SubjectFull: Natural gas
        Type: general
      – SubjectFull: Thermoelectricity
        Type: general
      – SubjectFull: Flame stability
        Type: general
    Titles:
      – TitleFull: EXPERIMENTAL MEASUREMENTS AT THE STEAM GENERATOR OF THE 330 MW POWER PLANT.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Racoceanu, Cristinel
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 07
              Text: 2025
              Type: published
              Y: 2025
          Identifiers:
            – Type: issn-print
              Value: 18424856
          Numbering:
            – Type: issue
              Value: 3
          Titles:
            – TitleFull: Annals of 'Constantin Brancusi' University of Targu-Jiu. Engineering Series / Analele Universităţii Constantin Brâncuşi din Târgu-Jiu. Seria Inginerie
              Type: main
ResultId 1