EXPERIMENTAL MEASUREMENTS AT THE STEAM GENERATOR OF THE 330 MW POWER PLANT.
Saved in:
| Title: | EXPERIMENTAL MEASUREMENTS AT THE STEAM GENERATOR OF THE 330 MW POWER PLANT. |
|---|---|
| Authors: | Racoceanu, Cristinel1 |
| Source: | Annals of 'Constantin Brancusi' University of Targu-Jiu. Engineering Series / Analele Universităţii Constantin Brâncuşi din Târgu-Jiu. Seria Inginerie. 2025, Issue 3, p118-123. 6p. |
| Subjects: | Steam generators, Coal-fired power plants, Coal, Empirical research, Natural gas, Thermoelectricity, Flame stability |
| Abstract: | This paper presents a case study on experimental measurements performed on the steam generator of power unit no. 5 at the Rovinari thermoelectric power plant. The 1035 t/h Benson steam generator operates with coal, and natural gas is used for ignition and flame stability. [ABSTRACT FROM AUTHOR] |
| Copyright of Annals of 'Constantin Brancusi' University of Targu-Jiu. Engineering Series / Analele Universităţii Constantin Brâncuşi din Târgu-Jiu. Seria Inginerie is the property of Universitatea Constantin Brancusi din Targu-Jiu and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Links: – Type: pdflink Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 189896407 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: EXPERIMENTAL MEASUREMENTS AT THE STEAM GENERATOR OF THE 330 MW POWER PLANT. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Racoceanu%2C+Cristinel%22">Racoceanu, Cristinel</searchLink><relatesTo>1</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Annals+of+'Constantin+Brancusi'+University+of+Targu-Jiu%2E+Engineering+Series+%2F+Analele+Universităţii+Constantin+Brâncuşi+din+Târgu-Jiu%2E+Seria+Inginerie%22">Annals of 'Constantin Brancusi' University of Targu-Jiu. Engineering Series / Analele Universităţii Constantin Brâncuşi din Târgu-Jiu. Seria Inginerie</searchLink>. 2025, Issue 3, p118-123. 6p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Steam+generators%22">Steam generators</searchLink><br /><searchLink fieldCode="DE" term="%22Coal-fired+power+plants%22">Coal-fired power plants</searchLink><br /><searchLink fieldCode="DE" term="%22Coal%22">Coal</searchLink><br /><searchLink fieldCode="DE" term="%22Empirical+research%22">Empirical research</searchLink><br /><searchLink fieldCode="DE" term="%22Natural+gas%22">Natural gas</searchLink><br /><searchLink fieldCode="DE" term="%22Thermoelectricity%22">Thermoelectricity</searchLink><br /><searchLink fieldCode="DE" term="%22Flame+stability%22">Flame stability</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: This paper presents a case study on experimental measurements performed on the steam generator of power unit no. 5 at the Rovinari thermoelectric power plant. The 1035 t/h Benson steam generator operates with coal, and natural gas is used for ignition and flame stability. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Annals of 'Constantin Brancusi' University of Targu-Jiu. Engineering Series / Analele Universităţii Constantin Brâncuşi din Târgu-Jiu. Seria Inginerie is the property of Universitatea Constantin Brancusi din Targu-Jiu and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=189896407 |
| RecordInfo | BibRecord: BibEntity: Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 6 StartPage: 118 Subjects: – SubjectFull: Steam generators Type: general – SubjectFull: Coal-fired power plants Type: general – SubjectFull: Coal Type: general – SubjectFull: Empirical research Type: general – SubjectFull: Natural gas Type: general – SubjectFull: Thermoelectricity Type: general – SubjectFull: Flame stability Type: general Titles: – TitleFull: EXPERIMENTAL MEASUREMENTS AT THE STEAM GENERATOR OF THE 330 MW POWER PLANT. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Racoceanu, Cristinel IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 07 Text: 2025 Type: published Y: 2025 Identifiers: – Type: issn-print Value: 18424856 Numbering: – Type: issue Value: 3 Titles: – TitleFull: Annals of 'Constantin Brancusi' University of Targu-Jiu. Engineering Series / Analele Universităţii Constantin Brâncuşi din Târgu-Jiu. Seria Inginerie Type: main |
| ResultId | 1 |