Investigating the potential of combining Raman spectroscopy and machine learning for gestational age classification in rat cervical tissue.

Saved in:
Bibliographic Details
Title: Investigating the potential of combining Raman spectroscopy and machine learning for gestational age classification in rat cervical tissue.
Authors: Tekin, Metin1 (AUTHOR), Simsek, Cemaleddin1,2 (AUTHOR) csimsek@kmu.edu.tr, Buyukkurt, Selim3 (AUTHOR), Unal, Mustafa1,4,5,6 (AUTHOR) munal@bidmc.harvard.edu
Source: Spectrochimica Acta Part A: Molecular & Biomolecular Spectroscopy. Mar2026:Part 2, Vol. 348, pN.PAG-N.PAG. 1p.
Subjects: Raman spectroscopy, Machine learning, Tissues, Gestational age, Physiology, Premature labor
Abstract: Spontaneous preterm birth (SPB) is a leading cause of neonatal morbidity and mortality worldwide. It occurs when the uterine cervix (UC) opens prematurely due to various biological factors. Early detection is crucial to reducing its adverse outcomes. Current prediction methods, such as cervical length measurement and fetal fibronectin testing, often suffer from high false-positive rates due to the heterogeneous nature of SPB. Prior to labor, significant biochemical changes occur in the cervical tissue. Raman spectroscopy (RS), a non-invasive and label-free technique, can detect these molecular alterations without harming the mother or fetus. This study represents the first application of RS combined with machine learning (ML) algorithms for gestational age classification in rat cervical tissue. Ex vivo Raman spectra were collected from Wistar-Albino rats on gestational days 15, 17, 18, 19, and 20, yielding a dataset of 600 spectra. Several ML algorithms were evaluated, including decision trees, random forests, support vector machines (SVM), K-nearest neighbors (K−NN), and Artificial neural networks (ANN). Among these, the ANN model achieved the highest classification accuracy (87.5 %), outperforming other ML models (58–69 %). Notably, spectra from gestational day 19 showed increased misclassification, which likely reflects heightened biochemical variability in the cervix during late pregnancy. These findings demonstrate that integrating RS with ML, particularly ANN, provides a promising approach for classifying gestational stage based on cervical biochemical composition. This study supports the potential of RS as a non-invasive tool for monitoring pregnancy progression and lays the groundwork for future clinical applications in early SPB risk assessment. [Display omitted] • Introduces a novel integration of full-spectrum Raman spectroscopy with artificial intelligence/machine learning for gestational stage classification. • Demonstrates accurate gestational stage classification using ex vivo rat cervical tissue spectra. • Achieves 87.5 % classification accuracy with artificial neural network outperforming other ML models. • Establishes a proof-of-concept for RS–AI approaches in non-invasive preterm birth risk assessment. [ABSTRACT FROM AUTHOR]
Copyright of Spectrochimica Acta Part A: Molecular & Biomolecular Spectroscopy is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:Spontaneous preterm birth (SPB) is a leading cause of neonatal morbidity and mortality worldwide. It occurs when the uterine cervix (UC) opens prematurely due to various biological factors. Early detection is crucial to reducing its adverse outcomes. Current prediction methods, such as cervical length measurement and fetal fibronectin testing, often suffer from high false-positive rates due to the heterogeneous nature of SPB. Prior to labor, significant biochemical changes occur in the cervical tissue. Raman spectroscopy (RS), a non-invasive and label-free technique, can detect these molecular alterations without harming the mother or fetus. This study represents the first application of RS combined with machine learning (ML) algorithms for gestational age classification in rat cervical tissue. Ex vivo Raman spectra were collected from Wistar-Albino rats on gestational days 15, 17, 18, 19, and 20, yielding a dataset of 600 spectra. Several ML algorithms were evaluated, including decision trees, random forests, support vector machines (SVM), K-nearest neighbors (K−NN), and Artificial neural networks (ANN). Among these, the ANN model achieved the highest classification accuracy (87.5 %), outperforming other ML models (58–69 %). Notably, spectra from gestational day 19 showed increased misclassification, which likely reflects heightened biochemical variability in the cervix during late pregnancy. These findings demonstrate that integrating RS with ML, particularly ANN, provides a promising approach for classifying gestational stage based on cervical biochemical composition. This study supports the potential of RS as a non-invasive tool for monitoring pregnancy progression and lays the groundwork for future clinical applications in early SPB risk assessment. [Display omitted] • Introduces a novel integration of full-spectrum Raman spectroscopy with artificial intelligence/machine learning for gestational stage classification. • Demonstrates accurate gestational stage classification using ex vivo rat cervical tissue spectra. • Achieves 87.5 % classification accuracy with artificial neural network outperforming other ML models. • Establishes a proof-of-concept for RS–AI approaches in non-invasive preterm birth risk assessment. [ABSTRACT FROM AUTHOR]
ISSN:13861425
DOI:10.1016/j.saa.2025.127094