Cyclic Superelasticity, Elastocaloric Effect, and Shape Memory Effect of Solution-Treated Ti 50 Ni 41 Cu 7 Co 2 Alloy.

Saved in:
Bibliographic Details
Title: Cyclic Superelasticity, Elastocaloric Effect, and Shape Memory Effect of Solution-Treated Ti 50 Ni 41 Cu 7 Co 2 Alloy.
Authors: Choudhry, Niranjan Kumar1 (AUTHOR), Chou, Da-Syuan1,2 (AUTHOR), Chen, Chih-Hsuan1,2 (AUTHOR) chchen23@ntu.edu.tw
Source: Materials (1996-1944). Dec2025, Vol. 18 Issue 24, p5489. 17p.
Subjects: Shape memory effect, Shape memory alloys, Temperature effect, Alloys, Strains & stresses (Mechanics), Materials testing, Phase transitions
Abstract: Highlights: What are the main findings? Superelastic cycle test transformed the stress–strain curve into quasi-linear one with homogeneous strain. SME of 6.21% recoverable strain with 0.44% irrecoverable strain was obtained at a bias stress of 300 MPa. After training, transformation strain and elastocaloric effect became stable at 1.3%, and −4.3 K. A recoverable strain of about 0.5% was still achievable from up to 443 K. What are the implications of the main findings? Solution-treated Ti50Ni41Cu7Co2 SMA exhibited stable functionalities after 100 cycles. Cyclic superelasticity test significantly stabilizes the residual martensite even up to 573 K. Further improvement of the performance can be achieved by alloy design and microstructural control. In recent years, there has been an increasing interest in studying multi-component alloys. A bulk solution-treated Ti50Ni41Cu7Co2 SMA was prepared and investigated. The functional properties, including phase transformation temperature, shape memory effect, cyclic superelasticity, and elastocaloric response, were systematically evaluated. The alloy exhibited a Ms temperature of around 250 K, which is beneficial for applications at room temperature. Shape memory effect with a maximum recoverable strain of 6.21% was obtained under a biased stress of 300 MPa. The superelasticity rapidly became stable during the cyclic test, reducing irrecoverable strain from 2.8% to 0.01% by the 10th cycle. After 250th superelastic cycles, the alloy exhibited a stable recoverable strain of 1.3%, and a lower critical stress for transformation (270 MPa, down from 405 MPa). The elastocaloric cooling effect reached −4.9 K at the 50th cycle and stabilized at −4.3 K thereafter. With an increase in operating temperature, the elastocaloric effect diminished and disappeared above 383 K, and the SMA retained a notable recoverable strain of ~0.5% up to 443 K. [ABSTRACT FROM AUTHOR]
Copyright of Materials (1996-1944) is the property of MDPI and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
Description
Abstract:Highlights: What are the main findings? Superelastic cycle test transformed the stress–strain curve into quasi-linear one with homogeneous strain. SME of 6.21% recoverable strain with 0.44% irrecoverable strain was obtained at a bias stress of 300 MPa. After training, transformation strain and elastocaloric effect became stable at 1.3%, and −4.3 K. A recoverable strain of about 0.5% was still achievable from up to 443 K. What are the implications of the main findings? Solution-treated Ti50Ni41Cu7Co2 SMA exhibited stable functionalities after 100 cycles. Cyclic superelasticity test significantly stabilizes the residual martensite even up to 573 K. Further improvement of the performance can be achieved by alloy design and microstructural control. In recent years, there has been an increasing interest in studying multi-component alloys. A bulk solution-treated Ti50Ni41Cu7Co2 SMA was prepared and investigated. The functional properties, including phase transformation temperature, shape memory effect, cyclic superelasticity, and elastocaloric response, were systematically evaluated. The alloy exhibited a Ms temperature of around 250 K, which is beneficial for applications at room temperature. Shape memory effect with a maximum recoverable strain of 6.21% was obtained under a biased stress of 300 MPa. The superelasticity rapidly became stable during the cyclic test, reducing irrecoverable strain from 2.8% to 0.01% by the 10th cycle. After 250th superelastic cycles, the alloy exhibited a stable recoverable strain of 1.3%, and a lower critical stress for transformation (270 MPa, down from 405 MPa). The elastocaloric cooling effect reached −4.9 K at the 50th cycle and stabilized at −4.3 K thereafter. With an increase in operating temperature, the elastocaloric effect diminished and disappeared above 383 K, and the SMA retained a notable recoverable strain of ~0.5% up to 443 K. [ABSTRACT FROM AUTHOR]
ISSN:19961944
DOI:10.3390/ma18245489