Trend Prediction of Valve Internal Leakage in Thermal Power Plants Based on Improved ARIMA-GARCH.
Saved in:
| Title: | Trend Prediction of Valve Internal Leakage in Thermal Power Plants Based on Improved ARIMA-GARCH. |
|---|---|
| Authors: | Hou, Ruichun1 (AUTHOR), Cong, Lin1,2 (AUTHOR), Li, Kaiyong1 (AUTHOR), Guo, Zihao2 (AUTHOR), Yuan, Xinghua2 (AUTHOR), He, Chengbing2 (AUTHOR) hcbyy@126.com |
| Source: | Energies (19961073). Dec2025, Vol. 18 Issue 23, p6275. 29p. |
| Subjects: | Time series analysis, Forecasting methodology, Trend analysis, Steam power plants, Robust statistics, Condition-based maintenance, Heteroscedasticity |
| Abstract: | Accurate trend prediction of valve internal leakage is crucial for the safe and economical operation of thermal power units. To address the issues of prediction lag and insufficient accuracy in existing methods when dealing with the dynamic changes in internal leakage, this paper proposed an Improved Autoregressive Integrated Moving Average–Generalized Autoregressive Conditional Heteroskedasticity (IARIMA-GARCH) method that integrated Multi-Time-Scale Decomposition, an Improved ARIMA (IARIMA) model, and an Improved GARCH (IGARCH) model for accurate prediction of drain valve internal leakage. First, using a Multi-Time-Scale Decomposition method based on sampling at different time intervals, the original valve internal leakage time series were reconstructed into three characteristic subsequences—short-term, medium-term, and long-term—to capture the evolutionary features at various time scales. Then, an IARIMA model, employing the Huber loss function for robust parameter estimation, was constructed as the leakage prediction model to effectively suppress the interference of outliers. Simultaneously, an IGARCH model was built as the leakage volatility prediction model by introducing the previous moment's volatility to correct the current residual, establishing a feedback mechanism between the mean and volatility equations, thereby enhancing the characterization of volatility clustering. Finally, using a weight coefficient dynamic calculation method based on RMSE, the Multi-Time-Scale prediction results of each subsequence were fused to obtain the final predicted valve internal leakage. Taking the main steam drain valve of a thermal power plant as the research object, and using Mean Absolute Error (MAE), Root-Mean-Squared Error (RMSE), Mean Absolute Percentage Error (MAPE), and symmetric Mean Absolute Percentage Error (sMAPE) as evaluation metrics, a case study on trend prediction of drain valve internal leakage was conducted, comparing the proposed method with ARIMA, Long Short-Term Memory networks (LSTM) and eXtreme Gradient Boosting (XGBoost) methods. The results showed that compared to ARIMA, LSTM and XGBoost, the proposed IARIMA-GARCH method achieved the lowest values on error metrics such as Mean Absolute Error (MAE), Root-Mean-Squared Error (RMSE), Mean Absolute Percentage Error (MAPE), and symmetric Mean Absolute Percentage Error (sMAPE), and its Coefficient of Determination (R2) is closest to 1. The standardized residual sequence most closely resembled a white noise sequence with zero mean and unit variance, and its distribution was the closest to a normal distribution. This proved that the IARIMA-GARCH method possessed higher prediction accuracy, stronger dynamic adaptability, and superior statistical robustness, providing an effective solution for valve condition prediction and predictive maintenance. [ABSTRACT FROM AUTHOR] |
| Copyright of Energies (19961073) is the property of MDPI and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| Abstract: | Accurate trend prediction of valve internal leakage is crucial for the safe and economical operation of thermal power units. To address the issues of prediction lag and insufficient accuracy in existing methods when dealing with the dynamic changes in internal leakage, this paper proposed an Improved Autoregressive Integrated Moving Average–Generalized Autoregressive Conditional Heteroskedasticity (IARIMA-GARCH) method that integrated Multi-Time-Scale Decomposition, an Improved ARIMA (IARIMA) model, and an Improved GARCH (IGARCH) model for accurate prediction of drain valve internal leakage. First, using a Multi-Time-Scale Decomposition method based on sampling at different time intervals, the original valve internal leakage time series were reconstructed into three characteristic subsequences—short-term, medium-term, and long-term—to capture the evolutionary features at various time scales. Then, an IARIMA model, employing the Huber loss function for robust parameter estimation, was constructed as the leakage prediction model to effectively suppress the interference of outliers. Simultaneously, an IGARCH model was built as the leakage volatility prediction model by introducing the previous moment's volatility to correct the current residual, establishing a feedback mechanism between the mean and volatility equations, thereby enhancing the characterization of volatility clustering. Finally, using a weight coefficient dynamic calculation method based on RMSE, the Multi-Time-Scale prediction results of each subsequence were fused to obtain the final predicted valve internal leakage. Taking the main steam drain valve of a thermal power plant as the research object, and using Mean Absolute Error (MAE), Root-Mean-Squared Error (RMSE), Mean Absolute Percentage Error (MAPE), and symmetric Mean Absolute Percentage Error (sMAPE) as evaluation metrics, a case study on trend prediction of drain valve internal leakage was conducted, comparing the proposed method with ARIMA, Long Short-Term Memory networks (LSTM) and eXtreme Gradient Boosting (XGBoost) methods. The results showed that compared to ARIMA, LSTM and XGBoost, the proposed IARIMA-GARCH method achieved the lowest values on error metrics such as Mean Absolute Error (MAE), Root-Mean-Squared Error (RMSE), Mean Absolute Percentage Error (MAPE), and symmetric Mean Absolute Percentage Error (sMAPE), and its Coefficient of Determination (R2) is closest to 1. The standardized residual sequence most closely resembled a white noise sequence with zero mean and unit variance, and its distribution was the closest to a normal distribution. This proved that the IARIMA-GARCH method possessed higher prediction accuracy, stronger dynamic adaptability, and superior statistical robustness, providing an effective solution for valve condition prediction and predictive maintenance. [ABSTRACT FROM AUTHOR] |
|---|---|
| ISSN: | 19961073 |
| DOI: | 10.3390/en18236275 |