Application of semipermeable membrane device for assessing toxicity in drinking water

Saved in:
Bibliographic Details
Title: Application of semipermeable membrane device for assessing toxicity in drinking water
Authors: Gilli, G.1 giorgio.gilli@unito.it, Schilirò, T.1, Pignata, C.1, Traversi, D.1, Carraro, E.2, Baiocchi, C.3, Aigotti, R.3, Giacosa, D.4, Fea, E.1
Source: Chemosphere. Dec2005, Vol. 61 Issue 11, p1691-1699. 9p.
Subjects: Drinking water, Toxicity testing, Ion-permeable membranes, Polycyclic aromatic hydrocarbons, Artificial membranes, Water
Abstract: Abstract: Semipermeable membrane devices (SPMDs) mimic passive diffusive transport of bioavailable hydrophobic organic compounds through biological membranes and their partitioning between lipids and environmental levels. Our study was developed on a surface water treatment plant based in Turin, Northern Italy. The investigated plant treats Po River surface water and it supplies about 20% of the drinking water required by Turin city (about one million inhabitants). Surface water (input) and drinking water (output) were monitored with SPMDs from October 2001 to January 2004, over a period of 30 days. The contaminant residues, monthly extracted from SPMDs by dialysis in organic solvent, were tested with the MicrotoxTM acute toxic test and with the Ames mutagenicity test. Same extracts were also analyzed with gaschromatography—mass spectrometry technique in order to characterise the organic pollutants sampled, especially Polycyclic Aromatic Hydrocarbons (PAHs). Although the PAHs mean concentration is about one hundred times lower in the output samples, the mean toxic units are similar in drinking and surface water. Our data indicate that the SPMD is a suitable tool to assess the possible toxicity in drinking water. [Copyright &y& Elsevier]
Copyright of Chemosphere is the property of Pergamon Press - An Imprint of Elsevier Science and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 19139041
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Application of semipermeable membrane device for assessing toxicity in drinking water
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Gilli%2C+G%2E%22">Gilli, G.</searchLink><relatesTo>1</relatesTo><i> giorgio.gilli@unito.it</i><br /><searchLink fieldCode="AR" term="%22Schilirò%2C+T%2E%22">Schilirò, T.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Pignata%2C+C%2E%22">Pignata, C.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Traversi%2C+D%2E%22">Traversi, D.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Carraro%2C+E%2E%22">Carraro, E.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Baiocchi%2C+C%2E%22">Baiocchi, C.</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Aigotti%2C+R%2E%22">Aigotti, R.</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Giacosa%2C+D%2E%22">Giacosa, D.</searchLink><relatesTo>4</relatesTo><br /><searchLink fieldCode="AR" term="%22Fea%2C+E%2E%22">Fea, E.</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Chemosphere%22">Chemosphere</searchLink>. Dec2005, Vol. 61 Issue 11, p1691-1699. 9p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Drinking+water%22">Drinking water</searchLink><br /><searchLink fieldCode="DE" term="%22Toxicity+testing%22">Toxicity testing</searchLink><br /><searchLink fieldCode="DE" term="%22Ion-permeable+membranes%22">Ion-permeable membranes</searchLink><br /><searchLink fieldCode="DE" term="%22Polycyclic+aromatic+hydrocarbons%22">Polycyclic aromatic hydrocarbons</searchLink><br /><searchLink fieldCode="DE" term="%22Artificial+membranes%22">Artificial membranes</searchLink><br /><searchLink fieldCode="DE" term="%22Water%22">Water</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Abstract: Semipermeable membrane devices (SPMDs) mimic passive diffusive transport of bioavailable hydrophobic organic compounds through biological membranes and their partitioning between lipids and environmental levels. Our study was developed on a surface water treatment plant based in Turin, Northern Italy. The investigated plant treats Po River surface water and it supplies about 20% of the drinking water required by Turin city (about one million inhabitants). Surface water (input) and drinking water (output) were monitored with SPMDs from October 2001 to January 2004, over a period of 30 days. The contaminant residues, monthly extracted from SPMDs by dialysis in organic solvent, were tested with the MicrotoxTM acute toxic test and with the Ames mutagenicity test. Same extracts were also analyzed with gaschromatography—mass spectrometry technique in order to characterise the organic pollutants sampled, especially Polycyclic Aromatic Hydrocarbons (PAHs). Although the PAHs mean concentration is about one hundred times lower in the output samples, the mean toxic units are similar in drinking and surface water. Our data indicate that the SPMD is a suitable tool to assess the possible toxicity in drinking water. [Copyright &y& Elsevier]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Chemosphere is the property of Pergamon Press - An Imprint of Elsevier Science and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=19139041
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.chemosphere.2005.03.085
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 9
        StartPage: 1691
    Subjects:
      – SubjectFull: Drinking water
        Type: general
      – SubjectFull: Toxicity testing
        Type: general
      – SubjectFull: Ion-permeable membranes
        Type: general
      – SubjectFull: Polycyclic aromatic hydrocarbons
        Type: general
      – SubjectFull: Artificial membranes
        Type: general
      – SubjectFull: Water
        Type: general
    Titles:
      – TitleFull: Application of semipermeable membrane device for assessing toxicity in drinking water
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Gilli, G.
      – PersonEntity:
          Name:
            NameFull: Schilirò, T.
      – PersonEntity:
          Name:
            NameFull: Pignata, C.
      – PersonEntity:
          Name:
            NameFull: Traversi, D.
      – PersonEntity:
          Name:
            NameFull: Carraro, E.
      – PersonEntity:
          Name:
            NameFull: Baiocchi, C.
      – PersonEntity:
          Name:
            NameFull: Aigotti, R.
      – PersonEntity:
          Name:
            NameFull: Giacosa, D.
      – PersonEntity:
          Name:
            NameFull: Fea, E.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 22
              M: 12
              Text: Dec2005
              Type: published
              Y: 2005
          Identifiers:
            – Type: issn-print
              Value: 00456535
          Numbering:
            – Type: volume
              Value: 61
            – Type: issue
              Value: 11
          Titles:
            – TitleFull: Chemosphere
              Type: main
ResultId 1