Immunodetection of Poorly Soluble Substances: Limitations and Their Overcoming.
Saved in:
| Title: | Immunodetection of Poorly Soluble Substances: Limitations and Their Overcoming. |
|---|---|
| Authors: | A. N., Berlina1 (AUTHOR) anberlina@yandex.ru, O. D., Hendrickson1 (AUTHOR), N. S., Komova1 (AUTHOR), A. V., Zherdev1 (AUTHOR), B. B., Dzantiev1 (AUTHOR) |
| Source: | Critical Reviews in Analytical Chemistry. 2026, Vol. 56 Issue 2, p209-234. 26p. |
| Subjects: | Immunoassay, Solubilization, Immunochemistry, Surface active agents, Hydrophobic interactions, Binding sites, Fullerenes, Hydrophobic compounds |
| Abstract: | Immunoassays based on the specific antigen—antibody interactions are efficient tools to detect various compounds and estimate their content. Usually, these assays are implemented in water-saline media with composition close to physiological conditions. However, many substances are insoluble or cannot be molecularly dispersed in such media, which objectively creates problems when interacting in aquatic environments. Thus, obtaining immunoreactants and implementing immunoassays of these substances need special methodological solutions. Hydrophobicity of antigens as well as their limited ability to functionalization and conjugation are often overlooked when developing immunoassays for these compounds. The main key finding is the possibility to influence the behavior of hydrophobic compounds for immunoassays, which requires specific approaches summarized in the review. Using the examples of two groups of compounds—surfactants (alkyl- and bisphenols) and fullerenes, we systematized the existing knowledge and experience in the development of immunoassays. This review addresses the challenges of immunodetection of poorly soluble substances and proposes solutions such as the use of hydrotropes, other solubilization techniques, and alternative receptors (aptamers and molecularly imprinted polymers). [ABSTRACT FROM AUTHOR] |
| Copyright of Critical Reviews in Analytical Chemistry is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 192005574 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Immunodetection of Poorly Soluble Substances: Limitations and Their Overcoming. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22A%2E+N%2E%2C+Berlina%22">A. N., Berlina</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> anberlina@yandex.ru</i><br /><searchLink fieldCode="AR" term="%22O%2E+D%2E%2C+Hendrickson%22">O. D., Hendrickson</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22N%2E+S%2E%2C+Komova%22">N. S., Komova</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22A%2E+V%2E%2C+Zherdev%22">A. V., Zherdev</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22B%2E+B%2E%2C+Dzantiev%22">B. B., Dzantiev</searchLink><relatesTo>1</relatesTo> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Critical+Reviews+in+Analytical+Chemistry%22">Critical Reviews in Analytical Chemistry</searchLink>. 2026, Vol. 56 Issue 2, p209-234. 26p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Immunoassay%22">Immunoassay</searchLink><br /><searchLink fieldCode="DE" term="%22Solubilization%22">Solubilization</searchLink><br /><searchLink fieldCode="DE" term="%22Immunochemistry%22">Immunochemistry</searchLink><br /><searchLink fieldCode="DE" term="%22Surface+active+agents%22">Surface active agents</searchLink><br /><searchLink fieldCode="DE" term="%22Hydrophobic+interactions%22">Hydrophobic interactions</searchLink><br /><searchLink fieldCode="DE" term="%22Binding+sites%22">Binding sites</searchLink><br /><searchLink fieldCode="DE" term="%22Fullerenes%22">Fullerenes</searchLink><br /><searchLink fieldCode="DE" term="%22Hydrophobic+compounds%22">Hydrophobic compounds</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Immunoassays based on the specific antigen—antibody interactions are efficient tools to detect various compounds and estimate their content. Usually, these assays are implemented in water-saline media with composition close to physiological conditions. However, many substances are insoluble or cannot be molecularly dispersed in such media, which objectively creates problems when interacting in aquatic environments. Thus, obtaining immunoreactants and implementing immunoassays of these substances need special methodological solutions. Hydrophobicity of antigens as well as their limited ability to functionalization and conjugation are often overlooked when developing immunoassays for these compounds. The main key finding is the possibility to influence the behavior of hydrophobic compounds for immunoassays, which requires specific approaches summarized in the review. Using the examples of two groups of compounds—surfactants (alkyl- and bisphenols) and fullerenes, we systematized the existing knowledge and experience in the development of immunoassays. This review addresses the challenges of immunodetection of poorly soluble substances and proposes solutions such as the use of hydrotropes, other solubilization techniques, and alternative receptors (aptamers and molecularly imprinted polymers). [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Critical Reviews in Analytical Chemistry is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=192005574 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1080/10408347.2024.2402835 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 26 StartPage: 209 Subjects: – SubjectFull: Immunoassay Type: general – SubjectFull: Solubilization Type: general – SubjectFull: Immunochemistry Type: general – SubjectFull: Surface active agents Type: general – SubjectFull: Hydrophobic interactions Type: general – SubjectFull: Binding sites Type: general – SubjectFull: Fullerenes Type: general – SubjectFull: Hydrophobic compounds Type: general Titles: – TitleFull: Immunodetection of Poorly Soluble Substances: Limitations and Their Overcoming. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: A. N., Berlina – PersonEntity: Name: NameFull: O. D., Hendrickson – PersonEntity: Name: NameFull: N. S., Komova – PersonEntity: Name: NameFull: A. V., Zherdev – PersonEntity: Name: NameFull: B. B., Dzantiev IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 02 Text: 2026 Type: published Y: 2026 Identifiers: – Type: issn-print Value: 10408347 Numbering: – Type: volume Value: 56 – Type: issue Value: 2 Titles: – TitleFull: Critical Reviews in Analytical Chemistry Type: main |
| ResultId | 1 |