Abstract: Silicon photomultiplier (SiPM) arrays are strong photodetector candidates for future RICH detectors owing to their excellent single-photon detection efficiency, time resolution and fine granularity. The main challenge in operating SiPM arrays is the dark-count rate (DCR), especially after irradiation damage. Operation at cryogenic temperature effectively mitigates the DCR. The design and integration of a cryostat in a RICH detector pose a technical challenge. A modular cryostat demonstrator is under development at CERN to characterise SiPM arrays at liquid-nitrogen temperatures (∼ 80 K) under different experimental conditions. The design of the demonstrator addresses key technical aspects such as the coupling of SiPM arrays to a cold block, the operation of multi-channel readout electronics in vacuum and the transmission of the SiPM analogue signals over distances of several centimetres. This demonstrator will provide valuable insights for the scalability of the system to large photodetector areas. A flex-PCB solution transmits the analogue signals from the cryogenically cooled SiPM arrays to the readout electronics at room temperature. A prototype of the flex-PCB was designed and produced to evaluate the effect of 15 cm-long high-density traces on signal integrity and time resolution. The results demonstrate that signal integrity is preserved and a single-photon time resolution of σ = 103 ± 5 ps was measured using a picosecond-pulsed laser setup at room temperature. [ABSTRACT FROM AUTHOR]
Copyright of Nuclear Instruments & Methods in Physics Research Section A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 193007221
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: A cryogenic RICH detector demonstrator for SiPM operation with flex-PCB readout.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Frei%2C+C%2E%22">Frei, C.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Keizer%2C+F%2E%22">Keizer, F.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Malentacca%2C+L%2E%22">Malentacca, L.</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<i> lorenzo.malentacca@cern.ch</i><br /><searchLink fieldCode="AR" term="%22Vilella%2C+A%2E+Murillo%22">Vilella, A. Murillo</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Piedigrossi%2C+D%2E%22">Piedigrossi, D.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Wertelaers%2C+P%2E%22">Wertelaers, P.</searchLink><relatesTo>1</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Nuclear+Instruments+%26+Methods+in+Physics+Research+Section+A%22">Nuclear Instruments & Methods in Physics Research Section A</searchLink>. Aug2026, Vol. 1088, pN.PAG-N.PAG. 1p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Photodetectors%22">Photodetectors</searchLink><br /><searchLink fieldCode="DE" term="%22Cryostats%22">Cryostats</searchLink><br /><searchLink fieldCode="DE" term="%22Time-resolved+measurements%22">Time-resolved measurements</searchLink><br /><searchLink fieldCode="DE" term="%22Signal+integrity+%28Electronics%29%22">Signal integrity (Electronics)</searchLink><br /><searchLink fieldCode="DE" term="%22European+Organization+for+Nuclear+Research%22">European Organization for Nuclear Research</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Silicon photomultiplier (SiPM) arrays are strong photodetector candidates for future RICH detectors owing to their excellent single-photon detection efficiency, time resolution and fine granularity. The main challenge in operating SiPM arrays is the dark-count rate (DCR), especially after irradiation damage. Operation at cryogenic temperature effectively mitigates the DCR. The design and integration of a cryostat in a RICH detector pose a technical challenge. A modular cryostat demonstrator is under development at CERN to characterise SiPM arrays at liquid-nitrogen temperatures (∼ 80 K) under different experimental conditions. The design of the demonstrator addresses key technical aspects such as the coupling of SiPM arrays to a cold block, the operation of multi-channel readout electronics in vacuum and the transmission of the SiPM analogue signals over distances of several centimetres. This demonstrator will provide valuable insights for the scalability of the system to large photodetector areas. A flex-PCB solution transmits the analogue signals from the cryogenically cooled SiPM arrays to the readout electronics at room temperature. A prototype of the flex-PCB was designed and produced to evaluate the effect of 15 cm-long high-density traces on signal integrity and time resolution. The results demonstrate that signal integrity is preserved and a single-photon time resolution of σ = 103 ± 5 ps was measured using a picosecond-pulsed laser setup at room temperature. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Nuclear Instruments & Methods in Physics Research Section A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=193007221
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.nima.2026.171510
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 1
        StartPage: N.PAG
    Subjects:
      – SubjectFull: Photodetectors
        Type: general
      – SubjectFull: Cryostats
        Type: general
      – SubjectFull: Time-resolved measurements
        Type: general
      – SubjectFull: Signal integrity (Electronics)
        Type: general
      – SubjectFull: European Organization for Nuclear Research
        Type: general
    Titles:
      – TitleFull: A cryogenic RICH detector demonstrator for SiPM operation with flex-PCB readout.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Frei, C.
      – PersonEntity:
          Name:
            NameFull: Keizer, F.
      – PersonEntity:
          Name:
            NameFull: Malentacca, L.
      – PersonEntity:
          Name:
            NameFull: Vilella, A. Murillo
      – PersonEntity:
          Name:
            NameFull: Piedigrossi, D.
      – PersonEntity:
          Name:
            NameFull: Wertelaers, P.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 08
              Text: Aug2026
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-print
              Value: 01689002
          Numbering:
            – Type: volume
              Value: 1088
          Titles:
            – TitleFull: Nuclear Instruments & Methods in Physics Research Section A
              Type: main
ResultId 1