Cycle Metrics and Strategy Detection for Automated Chair Sit-to-Stand Test Analysis Employing a Single Smartphone.

Saved in:
Bibliographic Details
Title: Cycle Metrics and Strategy Detection for Automated Chair Sit-to-Stand Test Analysis Employing a Single Smartphone.
Authors: Sher, Arshad1 (AUTHOR) arshad.sher@ntu.ac.uk, Rashid, Muntazir2 (AUTHOR) muntazirrashid50@gmail.com, Lotfi, Ahmad1 (AUTHOR) ahmad.lotfi@ntu.ac.uk, Povina, Federico3 (AUTHOR) fev1@aber.ac.uk, Akanyeti, Otar4 (AUTHOR) ota1@aber.ac.uk
Source: Annals of Biomedical Engineering. May2026, Vol. 54 Issue 5, p1471-1481. 11p.
Subjects: Motor ability testing, Physical mobility, Biomechanics, Wearable technology, Digital health, Signal processing
Abstract: Purpose: The 30-second Chair Sit-to-Stand Test (30 s CST) is widely used to assess lower-limb function and reflects complex motor coordination across neural systems. However, conventional scoring methods are often inconsistent and fail to capture variations in compensatory movement strategies or require invasive instrumentation. This study presents a smartphone-based system that automatically detects rising strategies across repeated CST cycles, providing an automated approach to extract cycle-level biomarkers of motor performance. Methods: Thirty-five adults 10 younger, 20 older, and 5 with Parkinson's disease performed supervised 30-s CST trials while wearing a waist-mounted smartphone that recorded accelerometer and gyroscope data at 400 Hz. Cycle detection used amplitude-adaptive thresholds and dominant-frequency intervals for robust segmentation of CST cycles. Rising strategies were classified with rule-based method that uses trunk pitch dynamics and cycle duration. Agreement with video annotations was assessed using Intraclass Correlation Coefficients (ICC (2, 1)), Bland–Altman analysis, and macro F1 scores. Results: The algorithm detected 660 CST cycles with 99% accuracy, and the average mean absolute error across participants was under 40 ms. Bland–Altman analysis showed negligible bias (− 0.012 s) and narrow limits of agreement (− 0.134 to 0.110 s). Strategy classification achieved macro F1 = 0.94. Flexion cycles were consistently longer than Momentum Transfer cycles (e.g., older adults: 2.63 vs. 1.45 s). Conclusion: Automated CST analysis reveals movement signatures not captured by standard timing, offering a richer characterization of mobility patterns. While these findings demonstrate technical feasibility and highlight clinically relevant variations, their application for diagnostic or personalized rehabilitation purposes remains preliminary and requires validation in larger cohorts. [ABSTRACT FROM AUTHOR]
Copyright of Annals of Biomedical Engineering is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 193086744
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Cycle Metrics and Strategy Detection for Automated Chair Sit-to-Stand Test Analysis Employing a Single Smartphone.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Sher%2C+Arshad%22">Sher, Arshad</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> arshad.sher@ntu.ac.uk</i><br /><searchLink fieldCode="AR" term="%22Rashid%2C+Muntazir%22">Rashid, Muntazir</searchLink><relatesTo>2</relatesTo> (AUTHOR)<i> muntazirrashid50@gmail.com</i><br /><searchLink fieldCode="AR" term="%22Lotfi%2C+Ahmad%22">Lotfi, Ahmad</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> ahmad.lotfi@ntu.ac.uk</i><br /><searchLink fieldCode="AR" term="%22Povina%2C+Federico%22">Povina, Federico</searchLink><relatesTo>3</relatesTo> (AUTHOR)<i> fev1@aber.ac.uk</i><br /><searchLink fieldCode="AR" term="%22Akanyeti%2C+Otar%22">Akanyeti, Otar</searchLink><relatesTo>4</relatesTo> (AUTHOR)<i> ota1@aber.ac.uk</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Annals+of+Biomedical+Engineering%22">Annals of Biomedical Engineering</searchLink>. May2026, Vol. 54 Issue 5, p1471-1481. 11p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Motor+ability+testing%22">Motor ability testing</searchLink><br /><searchLink fieldCode="DE" term="%22Physical+mobility%22">Physical mobility</searchLink><br /><searchLink fieldCode="DE" term="%22Biomechanics%22">Biomechanics</searchLink><br /><searchLink fieldCode="DE" term="%22Wearable+technology%22">Wearable technology</searchLink><br /><searchLink fieldCode="DE" term="%22Digital+health%22">Digital health</searchLink><br /><searchLink fieldCode="DE" term="%22Signal+processing%22">Signal processing</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose: The 30-second Chair Sit-to-Stand Test (30 s CST) is widely used to assess lower-limb function and reflects complex motor coordination across neural systems. However, conventional scoring methods are often inconsistent and fail to capture variations in compensatory movement strategies or require invasive instrumentation. This study presents a smartphone-based system that automatically detects rising strategies across repeated CST cycles, providing an automated approach to extract cycle-level biomarkers of motor performance. Methods: Thirty-five adults 10 younger, 20 older, and 5 with Parkinson's disease performed supervised 30-s CST trials while wearing a waist-mounted smartphone that recorded accelerometer and gyroscope data at 400 Hz. Cycle detection used amplitude-adaptive thresholds and dominant-frequency intervals for robust segmentation of CST cycles. Rising strategies were classified with rule-based method that uses trunk pitch dynamics and cycle duration. Agreement with video annotations was assessed using Intraclass Correlation Coefficients (ICC (2, 1)), Bland–Altman analysis, and macro F1 scores. Results: The algorithm detected 660 CST cycles with 99% accuracy, and the average mean absolute error across participants was under 40 ms. Bland–Altman analysis showed negligible bias (− 0.012 s) and narrow limits of agreement (− 0.134 to 0.110 s). Strategy classification achieved macro F1 = 0.94. Flexion cycles were consistently longer than Momentum Transfer cycles (e.g., older adults: 2.63 vs. 1.45 s). Conclusion: Automated CST analysis reveals movement signatures not captured by standard timing, offering a richer characterization of mobility patterns. While these findings demonstrate technical feasibility and highlight clinically relevant variations, their application for diagnostic or personalized rehabilitation purposes remains preliminary and requires validation in larger cohorts. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Annals of Biomedical Engineering is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=193086744
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s10439-025-03943-4
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 11
        StartPage: 1471
    Subjects:
      – SubjectFull: Motor ability testing
        Type: general
      – SubjectFull: Physical mobility
        Type: general
      – SubjectFull: Biomechanics
        Type: general
      – SubjectFull: Wearable technology
        Type: general
      – SubjectFull: Digital health
        Type: general
      – SubjectFull: Signal processing
        Type: general
    Titles:
      – TitleFull: Cycle Metrics and Strategy Detection for Automated Chair Sit-to-Stand Test Analysis Employing a Single Smartphone.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Sher, Arshad
      – PersonEntity:
          Name:
            NameFull: Rashid, Muntazir
      – PersonEntity:
          Name:
            NameFull: Lotfi, Ahmad
      – PersonEntity:
          Name:
            NameFull: Povina, Federico
      – PersonEntity:
          Name:
            NameFull: Akanyeti, Otar
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 05
              Text: May2026
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-print
              Value: 00906964
          Numbering:
            – Type: volume
              Value: 54
            – Type: issue
              Value: 5
          Titles:
            – TitleFull: Annals of Biomedical Engineering
              Type: main