When Low Voltage Sparks High Drama: ICD Therapy in Ventricular Tachycardia.
Saved in:
| Title: | When Low Voltage Sparks High Drama: ICD Therapy in Ventricular Tachycardia. |
|---|---|
| Authors: | Goel, Shivam1 (AUTHOR), Kumar, Sumit1 (AUTHOR), Deepti, Siddharthan1 (AUTHOR) deeptikailath@gmail.com, Parakh, Neeraj1 (AUTHOR), Sharma, Gautam1 (AUTHOR), Naik, Nitish1 (AUTHOR) |
| Source: | Pacing & Clinical Electrophysiology. May2026, Vol. 49 Issue 5, p576-580. 5p. |
| Subjects: | Electric countershock, Cardiomyopathies, Electroconvulsive therapy, Ventricular tachycardia, Implantable cardioverter-defibrillators, Catheter ablation, Electrophysiology, Myocardial depressants, Algorithms |
| Abstract: | The article focuses on a case involving inappropriate shock delivery by a cardiac resynchronization therapy defibrillator (CRT-D) in a 61-year-old woman with non-ischemic cardiomyopathy and recurrent slow ventricular tachycardia (VT). The device’s VF/VT Therapy Assurance (VFTA) algorithm, designed to prevent under sensing of ventricular arrhythmias by detecting low-amplitude far-field signals and long RR intervals, temporarily reprogrammed the device to deliver a shock instead of the programmed anti-tachycardia pacing (ATP). Although the shock successfully terminated the VT, the algorithm’s reliance on far-field electrograms led to inappropriate therapy due to low voltage signals in this patient. The case highlights the need for individualized programming of the VFTA algorithm to avoid unnecessary shocks in patients with advanced cardiomyopathy. [Extracted from the article] |
| Copyright of Pacing & Clinical Electrophysiology is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 193321390 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: When Low Voltage Sparks High Drama: ICD Therapy in Ventricular Tachycardia. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Goel%2C+Shivam%22">Goel, Shivam</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kumar%2C+Sumit%22">Kumar, Sumit</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Deepti%2C+Siddharthan%22">Deepti, Siddharthan</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> deeptikailath@gmail.com</i><br /><searchLink fieldCode="AR" term="%22Parakh%2C+Neeraj%22">Parakh, Neeraj</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Sharma%2C+Gautam%22">Sharma, Gautam</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Naik%2C+Nitish%22">Naik, Nitish</searchLink><relatesTo>1</relatesTo> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Pacing+%26+Clinical+Electrophysiology%22">Pacing & Clinical Electrophysiology</searchLink>. May2026, Vol. 49 Issue 5, p576-580. 5p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Electric+countershock%22">Electric countershock</searchLink><br /><searchLink fieldCode="DE" term="%22Cardiomyopathies%22">Cardiomyopathies</searchLink><br /><searchLink fieldCode="DE" term="%22Electroconvulsive+therapy%22">Electroconvulsive therapy</searchLink><br /><searchLink fieldCode="DE" term="%22Ventricular+tachycardia%22">Ventricular tachycardia</searchLink><br /><searchLink fieldCode="DE" term="%22Implantable+cardioverter-defibrillators%22">Implantable cardioverter-defibrillators</searchLink><br /><searchLink fieldCode="DE" term="%22Catheter+ablation%22">Catheter ablation</searchLink><br /><searchLink fieldCode="DE" term="%22Electrophysiology%22">Electrophysiology</searchLink><br /><searchLink fieldCode="DE" term="%22Myocardial+depressants%22">Myocardial depressants</searchLink><br /><searchLink fieldCode="DE" term="%22Algorithms%22">Algorithms</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: The article focuses on a case involving inappropriate shock delivery by a cardiac resynchronization therapy defibrillator (CRT-D) in a 61-year-old woman with non-ischemic cardiomyopathy and recurrent slow ventricular tachycardia (VT). The device’s VF/VT Therapy Assurance (VFTA) algorithm, designed to prevent under sensing of ventricular arrhythmias by detecting low-amplitude far-field signals and long RR intervals, temporarily reprogrammed the device to deliver a shock instead of the programmed anti-tachycardia pacing (ATP). Although the shock successfully terminated the VT, the algorithm’s reliance on far-field electrograms led to inappropriate therapy due to low voltage signals in this patient. The case highlights the need for individualized programming of the VFTA algorithm to avoid unnecessary shocks in patients with advanced cardiomyopathy. [Extracted from the article] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Pacing & Clinical Electrophysiology is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=193321390 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1111/pace.70193 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 5 StartPage: 576 Subjects: – SubjectFull: Electric countershock Type: general – SubjectFull: Cardiomyopathies Type: general – SubjectFull: Electroconvulsive therapy Type: general – SubjectFull: Ventricular tachycardia Type: general – SubjectFull: Implantable cardioverter-defibrillators Type: general – SubjectFull: Catheter ablation Type: general – SubjectFull: Electrophysiology Type: general – SubjectFull: Myocardial depressants Type: general – SubjectFull: Algorithms Type: general Titles: – TitleFull: When Low Voltage Sparks High Drama: ICD Therapy in Ventricular Tachycardia. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Goel, Shivam – PersonEntity: Name: NameFull: Kumar, Sumit – PersonEntity: Name: NameFull: Deepti, Siddharthan – PersonEntity: Name: NameFull: Parakh, Neeraj – PersonEntity: Name: NameFull: Sharma, Gautam – PersonEntity: Name: NameFull: Naik, Nitish IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 05 Text: May2026 Type: published Y: 2026 Identifiers: – Type: issn-print Value: 01478389 Numbering: – Type: volume Value: 49 – Type: issue Value: 5 Titles: – TitleFull: Pacing & Clinical Electrophysiology Type: main |
| ResultId | 1 |