FLIP-HEDOS: a patient-specific blood dose quantification model during radiotherapy treatments.

Saved in:
Bibliographic Details
Title: FLIP-HEDOS: a patient-specific blood dose quantification model during radiotherapy treatments.
Authors: García-Cardosa, Marina1 (AUTHOR) mgarciacard@unav.es, Beekman, Chris2 (AUTHOR), Burguete, Javier1,3 (AUTHOR), Paganetti, Harald2 (AUTHOR)
Source: Physics in Medicine & Biology. 2026, Vol. 71 Issue 9, p1-12. 12p.
Subjects: Circulation models, Cardiac output, Radiotherapy, Image segmentation, Proton therapy
Abstract: Objective. To introduce FLIP-HEDOS, a blood dose modeling framework that combines patient-specific and generic circulatory data to enable individualized blood dose estimation during radiotherapy (RT) treatments and to overcome limitations of non-personalized approaches. Approach. Patient-specific images of vasculature were obtained from patients with thorax-abdomen or head-neck tumors treated with proton or photon RT. Large vessels from the tumor location were segmented, and their blood flow velocities were extracted from phase-contrast MRI. Movement of blood particles (BPs) was simulated using a Lagrangian approach along patient-specific flowlines in these vessels, forming the FLIP method. This circulation was incorporated into a standardized model (HEDOS) to form a closed-loop whole-body model that computes the spatiotemporal BP distribution and associated blood dose accumulation, accounting for dose delivery dynamics, dose rate and beam-on/beam-off times. Cardiac output (CO) was individualized to match each patient blood flow characteristics. FLIP-HEDOS retains the modular HEDOS architecture, extending its large vessel compartments with the FLIP approach patient-specific vessels represented as new compartments. Remaining compartments were adapted to preserve the standardized connectivity of the circulatory network. Main Results. The study quantified mean blood dose values and tracked the number of times BPs entered patient-specific compartments during dose delivery. Simulations were performed across a range of inter-beam intervals, and the three models FLIP (patient-specific vessels), HEDOS (generic whole-body), and FLIP-HEDOS (integrated model) were compared with respect to their resulting blood dose values. The comparison shows that when patient-specific information is incorporated in blood dose assessment, BPs experience higher radiation doses. Significance. FLIP-HEDOS proves that standardized vascular data can be effectively combined with patient-specific parameters to achieve physiologically realistic modeling of circulating blood. By enabling individualized CO and blood flow dynamics, the framework adapts to the anatomical and hemodynamic characteristics of each patient. [ABSTRACT FROM AUTHOR]
© 2025 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 193492468
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: FLIP-HEDOS: a patient-specific blood dose quantification model during radiotherapy treatments.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22García-Cardosa%2C+Marina%22">García-Cardosa, Marina</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> mgarciacard@unav.es</i><br /><searchLink fieldCode="AR" term="%22Beekman%2C+Chris%22">Beekman, Chris</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Burguete%2C+Javier%22">Burguete, Javier</searchLink><relatesTo>1,3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Paganetti%2C+Harald%22">Paganetti, Harald</searchLink><relatesTo>2</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Physics+in+Medicine+%26+Biology%22">Physics in Medicine & Biology</searchLink>. 2026, Vol. 71 Issue 9, p1-12. 12p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Circulation+models%22">Circulation models</searchLink><br /><searchLink fieldCode="DE" term="%22Cardiac+output%22">Cardiac output</searchLink><br /><searchLink fieldCode="DE" term="%22Radiotherapy%22">Radiotherapy</searchLink><br /><searchLink fieldCode="DE" term="%22Image+segmentation%22">Image segmentation</searchLink><br /><searchLink fieldCode="DE" term="%22Proton+therapy%22">Proton therapy</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Objective. To introduce FLIP-HEDOS, a blood dose modeling framework that combines patient-specific and generic circulatory data to enable individualized blood dose estimation during radiotherapy (RT) treatments and to overcome limitations of non-personalized approaches. Approach. Patient-specific images of vasculature were obtained from patients with thorax-abdomen or head-neck tumors treated with proton or photon RT. Large vessels from the tumor location were segmented, and their blood flow velocities were extracted from phase-contrast MRI. Movement of blood particles (BPs) was simulated using a Lagrangian approach along patient-specific flowlines in these vessels, forming the FLIP method. This circulation was incorporated into a standardized model (HEDOS) to form a closed-loop whole-body model that computes the spatiotemporal BP distribution and associated blood dose accumulation, accounting for dose delivery dynamics, dose rate and beam-on/beam-off times. Cardiac output (CO) was individualized to match each patient blood flow characteristics. FLIP-HEDOS retains the modular HEDOS architecture, extending its large vessel compartments with the FLIP approach patient-specific vessels represented as new compartments. Remaining compartments were adapted to preserve the standardized connectivity of the circulatory network. Main Results. The study quantified mean blood dose values and tracked the number of times BPs entered patient-specific compartments during dose delivery. Simulations were performed across a range of inter-beam intervals, and the three models FLIP (patient-specific vessels), HEDOS (generic whole-body), and FLIP-HEDOS (integrated model) were compared with respect to their resulting blood dose values. The comparison shows that when patient-specific information is incorporated in blood dose assessment, BPs experience higher radiation doses. Significance. FLIP-HEDOS proves that standardized vascular data can be effectively combined with patient-specific parameters to achieve physiologically realistic modeling of circulating blood. By enabling individualized CO and blood flow dynamics, the framework adapts to the anatomical and hemodynamic characteristics of each patient. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>© 2025 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=193492468
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1088/1361-6560/ae6015
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 12
        StartPage: 1
    Subjects:
      – SubjectFull: Circulation models
        Type: general
      – SubjectFull: Cardiac output
        Type: general
      – SubjectFull: Radiotherapy
        Type: general
      – SubjectFull: Image segmentation
        Type: general
      – SubjectFull: Proton therapy
        Type: general
    Titles:
      – TitleFull: FLIP-HEDOS: a patient-specific blood dose quantification model during radiotherapy treatments.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: García-Cardosa, Marina
      – PersonEntity:
          Name:
            NameFull: Beekman, Chris
      – PersonEntity:
          Name:
            NameFull: Burguete, Javier
      – PersonEntity:
          Name:
            NameFull: Paganetti, Harald
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 14
              M: 05
              Text: 2026
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-print
              Value: 00319155
          Numbering:
            – Type: volume
              Value: 71
            – Type: issue
              Value: 9
          Titles:
            – TitleFull: Physics in Medicine & Biology
              Type: main
ResultId 1