Optimization of mass-spectrometer acquisition parameters for trace element analysis by LA-ICP-MS using magnetic sector instrument Element2.

Saved in:
Bibliographic Details
Title: Optimization of mass-spectrometer acquisition parameters for trace element analysis by LA-ICP-MS using magnetic sector instrument Element2.
Authors: Okina, O. I.1 (AUTHOR) okina@bk.ru, Erofeeva, K. G.1 (AUTHOR), Dubenskiy, A. S.1 (AUTHOR), Karimov, A. A.2 (AUTHOR), Ivanov, A. V.2 (AUTHOR)
Source: JAAS (Journal of Analytical Atomic Spectrometry). May2026, Vol. 41 Issue 5, p1938-1950. 13p.
Subjects: Trace element analysis, Laser ablation, Rare earth metals, Magnetic spectrometer, Mass spectrometry, Olivine, Chemical elements, Mathematical optimization
Abstract: Acquisition parameters for trace element analysis of minerals with the magnetic sector mass-spectrometer Element2 using laser ablation are discussed in the article. The main criteria for the parameters to be considered are optimal signal quality that would result in lowest values for limit of detection (LOD). Also, mineral analysis duration was taken into account in this work. The relationship between sample time and the number of runs was studied in the determination of REE, Y, and Nb in olivine that has low concentrations of these elements. Sample time was investigated in the range of 5–40 ms. Increasing the sample time resulted in a lowering of the standard deviation of analysis results and the LOD, although number of runs was significantly decreased. Additionally, the best way to minimize time of the analysis while maintaining signal quality was to use highest values for sample per peak and lowest mass window. The optimized acquisition parameters were determined as 100 samples per peak, a mass window of 4%, and a sample time of 20 ms. The possibility to reduce laser ablation up to 10 s (4 calculation runs) without loss of results' quality was demonstrated under the studied conditions. This reduction could be beneficial for the analysis of thin mineral grains. The parameters were applied to the trace element analysis of olivine Shc, which has a similar origin to new olivine reference material MongOLSh11-2. Grains of different tints of color ranging from practically colorless and light green to light yellow and yellow were analysed. Despite significant concentration differences between grains of various colors, normalized REE distribution patterns were similar across all analysed grains. Therefore, this sample could serve as a within-laboratory reference standard for routine trace element analysis of olivine using LA-ICP-MS. Furthermore, olivine San Carlos, a widely used standard to validate analytical data, was also analysed using the optimized parameters. The results obtained in this study are consistent with literature data and supplement it with Lu concentrations. [ABSTRACT FROM AUTHOR]
Copyright of JAAS (Journal of Analytical Atomic Spectrometry) is the property of Royal Society of Chemistry and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 193714413
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Optimization of mass-spectrometer acquisition parameters for trace element analysis by LA-ICP-MS using magnetic sector instrument Element2.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Okina%2C+O%2E+I%2E%22">Okina, O. I.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> okina@bk.ru</i><br /><searchLink fieldCode="AR" term="%22Erofeeva%2C+K%2E+G%2E%22">Erofeeva, K. G.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Dubenskiy%2C+A%2E+S%2E%22">Dubenskiy, A. S.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Karimov%2C+A%2E+A%2E%22">Karimov, A. A.</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Ivanov%2C+A%2E+V%2E%22">Ivanov, A. V.</searchLink><relatesTo>2</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22JAAS+%28Journal+of+Analytical+Atomic+Spectrometry%29%22">JAAS (Journal of Analytical Atomic Spectrometry)</searchLink>. May2026, Vol. 41 Issue 5, p1938-1950. 13p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Trace+element+analysis%22">Trace element analysis</searchLink><br /><searchLink fieldCode="DE" term="%22Laser+ablation%22">Laser ablation</searchLink><br /><searchLink fieldCode="DE" term="%22Rare+earth+metals%22">Rare earth metals</searchLink><br /><searchLink fieldCode="DE" term="%22Magnetic+spectrometer%22">Magnetic spectrometer</searchLink><br /><searchLink fieldCode="DE" term="%22Mass+spectrometry%22">Mass spectrometry</searchLink><br /><searchLink fieldCode="DE" term="%22Olivine%22">Olivine</searchLink><br /><searchLink fieldCode="DE" term="%22Chemical+elements%22">Chemical elements</searchLink><br /><searchLink fieldCode="DE" term="%22Mathematical+optimization%22">Mathematical optimization</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Acquisition parameters for trace element analysis of minerals with the magnetic sector mass-spectrometer Element2 using laser ablation are discussed in the article. The main criteria for the parameters to be considered are optimal signal quality that would result in lowest values for limit of detection (LOD). Also, mineral analysis duration was taken into account in this work. The relationship between sample time and the number of runs was studied in the determination of REE, Y, and Nb in olivine that has low concentrations of these elements. Sample time was investigated in the range of 5–40 ms. Increasing the sample time resulted in a lowering of the standard deviation of analysis results and the LOD, although number of runs was significantly decreased. Additionally, the best way to minimize time of the analysis while maintaining signal quality was to use highest values for sample per peak and lowest mass window. The optimized acquisition parameters were determined as 100 samples per peak, a mass window of 4%, and a sample time of 20 ms. The possibility to reduce laser ablation up to 10 s (4 calculation runs) without loss of results' quality was demonstrated under the studied conditions. This reduction could be beneficial for the analysis of thin mineral grains. The parameters were applied to the trace element analysis of olivine Shc, which has a similar origin to new olivine reference material MongOLSh11-2. Grains of different tints of color ranging from practically colorless and light green to light yellow and yellow were analysed. Despite significant concentration differences between grains of various colors, normalized REE distribution patterns were similar across all analysed grains. Therefore, this sample could serve as a within-laboratory reference standard for routine trace element analysis of olivine using LA-ICP-MS. Furthermore, olivine San Carlos, a widely used standard to validate analytical data, was also analysed using the optimized parameters. The results obtained in this study are consistent with literature data and supplement it with Lu concentrations. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of JAAS (Journal of Analytical Atomic Spectrometry) is the property of Royal Society of Chemistry and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=193714413
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1039/d6ja00038j
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 13
        StartPage: 1938
    Subjects:
      – SubjectFull: Trace element analysis
        Type: general
      – SubjectFull: Laser ablation
        Type: general
      – SubjectFull: Rare earth metals
        Type: general
      – SubjectFull: Magnetic spectrometer
        Type: general
      – SubjectFull: Mass spectrometry
        Type: general
      – SubjectFull: Olivine
        Type: general
      – SubjectFull: Chemical elements
        Type: general
      – SubjectFull: Mathematical optimization
        Type: general
    Titles:
      – TitleFull: Optimization of mass-spectrometer acquisition parameters for trace element analysis by LA-ICP-MS using magnetic sector instrument Element2.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Okina, O. I.
      – PersonEntity:
          Name:
            NameFull: Erofeeva, K. G.
      – PersonEntity:
          Name:
            NameFull: Dubenskiy, A. S.
      – PersonEntity:
          Name:
            NameFull: Karimov, A. A.
      – PersonEntity:
          Name:
            NameFull: Ivanov, A. V.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 05
              Text: May2026
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-print
              Value: 02679477
          Numbering:
            – Type: volume
              Value: 41
            – Type: issue
              Value: 5
          Titles:
            – TitleFull: JAAS (Journal of Analytical Atomic Spectrometry)
              Type: main