Hemocompatibility and cytotoxicity evaluation of additively manufactured and surface-treated 316 L stainless steel aortic stents using laser powder bed fusion (L-PBF).
Saved in:
| Title: | Hemocompatibility and cytotoxicity evaluation of additively manufactured and surface-treated 316 L stainless steel aortic stents using laser powder bed fusion (L-PBF). |
|---|---|
| Authors: | Lulla, Philipp1,2,3 (AUTHOR) philipp.lulla@oth-regensburg.de, Esper, Lukas4 (AUTHOR), Noster, Ulf4 (AUTHOR), Schratzenstaller, Thomas1,2,5 (AUTHOR), Schmid, Christof6 (AUTHOR), Lehle, Karla6 (AUTHOR) |
| Source: | Journal of Materials Science: Materials in Medicine. 5/27/2026, Vol. 37 Issue 1, p1-23. 23p. |
| Subjects: | Surgical stents, Powder bed fusion, Cell survival, Biocompatibility, Surface preparation, Austenitic stainless steel |
| Abstract: | New developments are needed in aortic replacement, with current hybrid solutions suffering from insufficient and rigid stent diameters, thus hindering minimization of false lumen in aortic dissection. Laser powder bed fusion (L-PBF) is an attractive method to generate a new-generation aortic stent. This study investigates the effects of 316 L stainless steel samples manufactured using the L-PBF process on the activity of fibroblasts, red blood cells, leukocytes and platelets on the modified surfaces. Cytotoxicity and hemocompatibility were analyzed under static culture conditions using immunofluorescence as well as scanning electron microscopic (SEM) techniques. Surfaces of additively manufactured samples were etched, electropolished, heat‑treated, and mechanically expanded to optimize the material's mechanical performance. Alone heat treatment increased the ultimate tensile strength from 585 ± 5 MPa to 695 ± 6 MPa. The additive manufactured and post-processed stents were non-cytotoxic (viability, > 70%, independent of the manufacturing status), non-hemolytic (hemolysis rate, < 1%), and were covered with only a few neutrophils (median (IQR), 25 (12-48) per mm2) and platelets (cellular coverage, 0.5 - 10%). Material-induced formation of neutrophil extracellular traps (NETs) was low and not quantifiable. More than 80% of adherent platelets presented an activated conformation and increased expression of CD62P. In contrast, neither circulating leukocytes nor platelets in the supernatant showed any material-induced stimulation as detected via flow cytometry. The results described herein are encouraging and suggest that additive manufactured metallic stents are bio- and hemocompatible and an adequate candidate material for personalized stent production in a very short time. [ABSTRACT FROM AUTHOR] |
| Copyright of Journal of Materials Science: Materials in Medicine is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 194093242 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Hemocompatibility and cytotoxicity evaluation of additively manufactured and surface-treated 316 L stainless steel aortic stents using laser powder bed fusion (L-PBF). – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Lulla%2C+Philipp%22">Lulla, Philipp</searchLink><relatesTo>1,2,3</relatesTo> (AUTHOR)<i> philipp.lulla@oth-regensburg.de</i><br /><searchLink fieldCode="AR" term="%22Esper%2C+Lukas%22">Esper, Lukas</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Noster%2C+Ulf%22">Noster, Ulf</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Schratzenstaller%2C+Thomas%22">Schratzenstaller, Thomas</searchLink><relatesTo>1,2,5</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Schmid%2C+Christof%22">Schmid, Christof</searchLink><relatesTo>6</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Lehle%2C+Karla%22">Lehle, Karla</searchLink><relatesTo>6</relatesTo> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Journal+of+Materials+Science%3A+Materials+in+Medicine%22">Journal of Materials Science: Materials in Medicine</searchLink>. 5/27/2026, Vol. 37 Issue 1, p1-23. 23p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Surgical+stents%22">Surgical stents</searchLink><br /><searchLink fieldCode="DE" term="%22Powder+bed+fusion%22">Powder bed fusion</searchLink><br /><searchLink fieldCode="DE" term="%22Cell+survival%22">Cell survival</searchLink><br /><searchLink fieldCode="DE" term="%22Biocompatibility%22">Biocompatibility</searchLink><br /><searchLink fieldCode="DE" term="%22Surface+preparation%22">Surface preparation</searchLink><br /><searchLink fieldCode="DE" term="%22Austenitic+stainless+steel%22">Austenitic stainless steel</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: New developments are needed in aortic replacement, with current hybrid solutions suffering from insufficient and rigid stent diameters, thus hindering minimization of false lumen in aortic dissection. Laser powder bed fusion (L-PBF) is an attractive method to generate a new-generation aortic stent. This study investigates the effects of 316 L stainless steel samples manufactured using the L-PBF process on the activity of fibroblasts, red blood cells, leukocytes and platelets on the modified surfaces. Cytotoxicity and hemocompatibility were analyzed under static culture conditions using immunofluorescence as well as scanning electron microscopic (SEM) techniques. Surfaces of additively manufactured samples were etched, electropolished, heat‑treated, and mechanically expanded to optimize the material's mechanical performance. Alone heat treatment increased the ultimate tensile strength from 585 ± 5 MPa to 695 ± 6 MPa. The additive manufactured and post-processed stents were non-cytotoxic (viability, > 70%, independent of the manufacturing status), non-hemolytic (hemolysis rate, < 1%), and were covered with only a few neutrophils (median (IQR), 25 (12-48) per mm2) and platelets (cellular coverage, 0.5 - 10%). Material-induced formation of neutrophil extracellular traps (NETs) was low and not quantifiable. More than 80% of adherent platelets presented an activated conformation and increased expression of CD62P. In contrast, neither circulating leukocytes nor platelets in the supernatant showed any material-induced stimulation as detected via flow cytometry. The results described herein are encouraging and suggest that additive manufactured metallic stents are bio- and hemocompatible and an adequate candidate material for personalized stent production in a very short time. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Journal of Materials Science: Materials in Medicine is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=194093242 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1007/s10856-026-07073-8 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 23 StartPage: 1 Subjects: – SubjectFull: Surgical stents Type: general – SubjectFull: Powder bed fusion Type: general – SubjectFull: Cell survival Type: general – SubjectFull: Biocompatibility Type: general – SubjectFull: Surface preparation Type: general – SubjectFull: Austenitic stainless steel Type: general Titles: – TitleFull: Hemocompatibility and cytotoxicity evaluation of additively manufactured and surface-treated 316 L stainless steel aortic stents using laser powder bed fusion (L-PBF). Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Lulla, Philipp – PersonEntity: Name: NameFull: Esper, Lukas – PersonEntity: Name: NameFull: Noster, Ulf – PersonEntity: Name: NameFull: Schratzenstaller, Thomas – PersonEntity: Name: NameFull: Schmid, Christof – PersonEntity: Name: NameFull: Lehle, Karla IsPartOfRelationships: – BibEntity: Dates: – D: 27 M: 05 Text: 5/27/2026 Type: published Y: 2026 Identifiers: – Type: issn-print Value: 09574530 Numbering: – Type: volume Value: 37 – Type: issue Value: 1 Titles: – TitleFull: Journal of Materials Science: Materials in Medicine Type: main |
| ResultId | 1 |