Titanium Base-Free Multi-Unit Abutment Connections: A Critical Review of Prosthetic Screw Design, Biomechanical Behavior, and Clinical Performance.

Saved in:
Bibliographic Details
Title: Titanium Base-Free Multi-Unit Abutment Connections: A Critical Review of Prosthetic Screw Design, Biomechanical Behavior, and Clinical Performance.
Authors: Mosaddad, Seyed Ali1,2 (AUTHOR), Rodríguez-Pérez, Iker1,2 (AUTHOR), Pieralli, Stefano3 (AUTHOR), Beuer, Florian3,4 (AUTHOR), Molinero-Mourelle, Pedro1,4,5 (AUTHOR), Çakmak, Gülce3,4,6 (AUTHOR)
Source: Materials (1996-1944). Jun2026, Vol. 19 Issue 11, p2212. 37p.
Subjects: Prosthetics, Biomechanics, Treatment effectiveness, Fatigue limit
Abstract: Highlights: Titanium base-free MUA systems increase dependence on prosthetic screw biomechanics. Preload maintenance and screw design are key to joint stability and fatigue resistance. Conical and modified head screws may improve load distribution and reduce loosening. Rigid materials like zirconia intensify stress at the screw–abutment interface. Clinical success depends on passive fit, torque control, and occlusal management. Titanium base-free multi-unit abutment (MUA) restorations have been introduced to simplify implant prosthetic workflows by eliminating intermediate titanium bases and bonding interfaces. However, this approach modifies the biomechanical behavior of the prosthesis–abutment–implant complex and increases reliance on prosthetic screw performance. Despite growing clinical and commercial interest in these systems, the available evidence remains limited and fragmented, and the biomechanical consequences of removing the titanium base have not been clearly synthesized. Therefore, this critical review evaluated the influence of prosthetic screw design on the biomechanical behavior of titanium base-free MUA restorations, focusing on preload maintenance, load transfer, and mechanical stability. The evidence indicates that preload loss, screw loosening, and fatigue behavior are primary determinants of mechanical performance. Screw material, surface characteristics, and head geometry may affect preload generation, load distribution, and resistance to micromovement, although current evidence remains limited and heterogeneous. Short-term clinical outcomes appear acceptable when appropriate biomechanical and prosthetic protocols are followed; however, long-term comparative data are lacking. Titanium base-free MUA restorations should be considered a technique-sensitive approach requiring optimized screw selection, accurate prosthetic fit, and controlled occlusal loading. Further well-designed long-term studies are needed to establish their predictability. [ABSTRACT FROM AUTHOR]
Copyright of Materials (1996-1944) is the property of MDPI and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 194587123
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Titanium Base-Free Multi-Unit Abutment Connections: A Critical Review of Prosthetic Screw Design, Biomechanical Behavior, and Clinical Performance.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Mosaddad%2C+Seyed+Ali%22">Mosaddad, Seyed Ali</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Rodríguez-Pérez%2C+Iker%22">Rodríguez-Pérez, Iker</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Pieralli%2C+Stefano%22">Pieralli, Stefano</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Beuer%2C+Florian%22">Beuer, Florian</searchLink><relatesTo>3,4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Molinero-Mourelle%2C+Pedro%22">Molinero-Mourelle, Pedro</searchLink><relatesTo>1,4,5</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Çakmak%2C+Gülce%22">Çakmak, Gülce</searchLink><relatesTo>3,4,6</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Materials+%281996-1944%29%22">Materials (1996-1944)</searchLink>. Jun2026, Vol. 19 Issue 11, p2212. 37p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Prosthetics%22">Prosthetics</searchLink><br /><searchLink fieldCode="DE" term="%22Biomechanics%22">Biomechanics</searchLink><br /><searchLink fieldCode="DE" term="%22Treatment+effectiveness%22">Treatment effectiveness</searchLink><br /><searchLink fieldCode="DE" term="%22Fatigue+limit%22">Fatigue limit</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Highlights: Titanium base-free MUA systems increase dependence on prosthetic screw biomechanics. Preload maintenance and screw design are key to joint stability and fatigue resistance. Conical and modified head screws may improve load distribution and reduce loosening. Rigid materials like zirconia intensify stress at the screw–abutment interface. Clinical success depends on passive fit, torque control, and occlusal management. Titanium base-free multi-unit abutment (MUA) restorations have been introduced to simplify implant prosthetic workflows by eliminating intermediate titanium bases and bonding interfaces. However, this approach modifies the biomechanical behavior of the prosthesis–abutment–implant complex and increases reliance on prosthetic screw performance. Despite growing clinical and commercial interest in these systems, the available evidence remains limited and fragmented, and the biomechanical consequences of removing the titanium base have not been clearly synthesized. Therefore, this critical review evaluated the influence of prosthetic screw design on the biomechanical behavior of titanium base-free MUA restorations, focusing on preload maintenance, load transfer, and mechanical stability. The evidence indicates that preload loss, screw loosening, and fatigue behavior are primary determinants of mechanical performance. Screw material, surface characteristics, and head geometry may affect preload generation, load distribution, and resistance to micromovement, although current evidence remains limited and heterogeneous. Short-term clinical outcomes appear acceptable when appropriate biomechanical and prosthetic protocols are followed; however, long-term comparative data are lacking. Titanium base-free MUA restorations should be considered a technique-sensitive approach requiring optimized screw selection, accurate prosthetic fit, and controlled occlusal loading. Further well-designed long-term studies are needed to establish their predictability. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Materials (1996-1944) is the property of MDPI and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=194587123
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.3390/ma19112212
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 37
        StartPage: 2212
    Subjects:
      – SubjectFull: Prosthetics
        Type: general
      – SubjectFull: Biomechanics
        Type: general
      – SubjectFull: Treatment effectiveness
        Type: general
      – SubjectFull: Fatigue limit
        Type: general
    Titles:
      – TitleFull: Titanium Base-Free Multi-Unit Abutment Connections: A Critical Review of Prosthetic Screw Design, Biomechanical Behavior, and Clinical Performance.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Mosaddad, Seyed Ali
      – PersonEntity:
          Name:
            NameFull: Rodríguez-Pérez, Iker
      – PersonEntity:
          Name:
            NameFull: Pieralli, Stefano
      – PersonEntity:
          Name:
            NameFull: Beuer, Florian
      – PersonEntity:
          Name:
            NameFull: Molinero-Mourelle, Pedro
      – PersonEntity:
          Name:
            NameFull: Çakmak, Gülce
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 06
              Text: Jun2026
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-print
              Value: 19961944
          Numbering:
            – Type: volume
              Value: 19
            – Type: issue
              Value: 11
          Titles:
            – TitleFull: Materials (1996-1944)
              Type: main
ResultId 1