Experimental investigation of drop-in substitutes for R134a in a small-scale vapor compression refrigeration system utilizing R513A and R1234yf with MATLAB analysis.

Saved in:
Bibliographic Details
Title: Experimental investigation of drop-in substitutes for R134a in a small-scale vapor compression refrigeration system utilizing R513A and R1234yf with MATLAB analysis.
Authors: Soni, Jyoti1 (AUTHOR) jyotisonijec@gmail.com, Chaube, Alok2 (AUTHOR), Jhinge, P. K.1 (AUTHOR)
Source: Sādhanā: Academy Proceedings in Engineering Sciences. Sep2026, Vol. 51 Issue 3, p1-19. 19p.
Subjects: Refrigerants, MatLab (Computer software), Vapor compression cycle, Energy consumption
Abstract: This work introduces an experimental investigation of a small-scale vapor compression refrigeration system initially intended for R134a, in light of research on energy and exergetic study. The investigation compares system performance to low-global warming potential (GWP) refrigerants R513A (GWP ≈ 573) and R1234yf, an ultra-low-GWP refrigerant (GWP ≈ 4). This study defines "low-GWP" refrigerants as those with a GWP below 700, according to California Air Resources Board (CARB) and Air Conditioning, Heating and refrigeration Institute (AHRI) criteria. Each refrigerant was evaluated at 250 g to promote the switch to ecologically friendly refrigerants and boost system efficiency. They were assessed for feasibility and performance in existing installations. A retrofit feasibility analysis of R513A and R1234yf was carried out in this study by using the change in the heating demand. Heating load varies across levels ranging from Level 1: 24 W, Level 2: 96 W, Level 3: 216 W, Level 4: 388 W, Level 5: 615 W, Level 6: 885 W, to Level 7: 1218 W. When it comes to oil compatibility, the study takes R1234yf in particular into consideration. A thermodynamic model has been created for investigation and simulation using the matrix laboratory (MATLAB) program. The test results showed that the system works well with both R134a and R513A at a charge of 250g. The research demonstrated that R134a and R513A are compatible with polyester (POE) oil inside the same system. On the other hand, when the same system was charged with an equivalent mass of R1234yf, the system did not work effectively because of the incompatibility between the oil and the R1234yf. In addition, as compared to the other refrigerants that were evaluated, R1234yf showed a substantially lower level of performance while using polyalkylene glycol (PAG) oil. R1234yf demonstrated the greatest exergy destruction at 2.28 W, followed by R513A at 1.93 W and R134a at 1.64 W. Exergy destruction for R1234yf was 28.07% greater than that of R134a and 15.35% greater than R513A. R134a demonstrated the highest exergetic efficiency at 35.81%, marginally surpassing R513A at 34.54% and significantly exceeding R1234yf at 24.43%, thereby indicating superior thermodynamic performance. R513A can be used instead of R134a because it works with POE oil, but R1234yf needs to have its oil changed and its system redesigned. [ABSTRACT FROM AUTHOR]
Copyright of Sādhanā: Academy Proceedings in Engineering Sciences is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 195652380
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Experimental investigation of drop-in substitutes for R134a in a small-scale vapor compression refrigeration system utilizing R513A and R1234yf with MATLAB analysis.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Soni%2C+Jyoti%22">Soni, Jyoti</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> jyotisonijec@gmail.com</i><br /><searchLink fieldCode="AR" term="%22Chaube%2C+Alok%22">Chaube, Alok</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Jhinge%2C+P%2E+K%2E%22">Jhinge, P. K.</searchLink><relatesTo>1</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Sādhanā%3A+Academy+Proceedings+in+Engineering+Sciences%22">Sādhanā: Academy Proceedings in Engineering Sciences</searchLink>. Sep2026, Vol. 51 Issue 3, p1-19. 19p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Refrigerants%22">Refrigerants</searchLink><br /><searchLink fieldCode="DE" term="%22MatLab+%28Computer+software%29%22">MatLab (Computer software)</searchLink><br /><searchLink fieldCode="DE" term="%22Vapor+compression+cycle%22">Vapor compression cycle</searchLink><br /><searchLink fieldCode="DE" term="%22Energy+consumption%22">Energy consumption</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: This work introduces an experimental investigation of a small-scale vapor compression refrigeration system initially intended for R134a, in light of research on energy and exergetic study. The investigation compares system performance to low-global warming potential (GWP) refrigerants R513A (GWP ≈ 573) and R1234yf, an ultra-low-GWP refrigerant (GWP ≈ 4). This study defines "low-GWP" refrigerants as those with a GWP below 700, according to California Air Resources Board (CARB) and Air Conditioning, Heating and refrigeration Institute (AHRI) criteria. Each refrigerant was evaluated at 250 g to promote the switch to ecologically friendly refrigerants and boost system efficiency. They were assessed for feasibility and performance in existing installations. A retrofit feasibility analysis of R513A and R1234yf was carried out in this study by using the change in the heating demand. Heating load varies across levels ranging from Level 1: 24 W, Level 2: 96 W, Level 3: 216 W, Level 4: 388 W, Level 5: 615 W, Level 6: 885 W, to Level 7: 1218 W. When it comes to oil compatibility, the study takes R1234yf in particular into consideration. A thermodynamic model has been created for investigation and simulation using the matrix laboratory (MATLAB) program. The test results showed that the system works well with both R134a and R513A at a charge of 250g. The research demonstrated that R134a and R513A are compatible with polyester (POE) oil inside the same system. On the other hand, when the same system was charged with an equivalent mass of R1234yf, the system did not work effectively because of the incompatibility between the oil and the R1234yf. In addition, as compared to the other refrigerants that were evaluated, R1234yf showed a substantially lower level of performance while using polyalkylene glycol (PAG) oil. R1234yf demonstrated the greatest exergy destruction at 2.28 W, followed by R513A at 1.93 W and R134a at 1.64 W. Exergy destruction for R1234yf was 28.07% greater than that of R134a and 15.35% greater than R513A. R134a demonstrated the highest exergetic efficiency at 35.81%, marginally surpassing R513A at 34.54% and significantly exceeding R1234yf at 24.43%, thereby indicating superior thermodynamic performance. R513A can be used instead of R134a because it works with POE oil, but R1234yf needs to have its oil changed and its system redesigned. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Sādhanā: Academy Proceedings in Engineering Sciences is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=195652380
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s12046-026-03216-3
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 19
        StartPage: 1
    Subjects:
      – SubjectFull: Refrigerants
        Type: general
      – SubjectFull: MatLab (Computer software)
        Type: general
      – SubjectFull: Vapor compression cycle
        Type: general
      – SubjectFull: Energy consumption
        Type: general
    Titles:
      – TitleFull: Experimental investigation of drop-in substitutes for R134a in a small-scale vapor compression refrigeration system utilizing R513A and R1234yf with MATLAB analysis.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Soni, Jyoti
      – PersonEntity:
          Name:
            NameFull: Chaube, Alok
      – PersonEntity:
          Name:
            NameFull: Jhinge, P. K.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 09
              Text: Sep2026
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-print
              Value: 02562499
          Numbering:
            – Type: volume
              Value: 51
            – Type: issue
              Value: 3
          Titles:
            – TitleFull: Sādhanā: Academy Proceedings in Engineering Sciences
              Type: main
ResultId 1