EMC above 1 GHz [electromagnetic compatibility].

Saved in:
Bibliographic Details
Title: EMC above 1 GHz [electromagnetic compatibility].
Authors: Marshall, R.1
Source: Communications Engineer. Feb2006, Vol. 4 Issue 1, p30-33. 4p. 5 Color Photographs.
Subjects: Electromagnetic compatibility, Communication in engineering, Frequency changers, Physics, Industrial research, Radio frequency
Abstract: While the need for electromagnetic compatibility (EMC) above 1 GHz has been long appreciated by the military, it has recently become of wide concern. The upward march of computer clock frequencies and the massive deployment of radio users of these frequencies have fueled this concern. There has always been difficulties in dealing with physically large equipments and the need to establish testing of everyday electronics above 1 GHz has brought objects into the "large compared with a wavelength" category. In this paper, the author discussed the increasing importance of electromagnetic compatibility at higher frequencies. All the presented discussions apply to the traditional "open area test site" which has been adopted by CISPR. At the seminar, opinions were divided on the wisdom of CISPR's choice of traditional test methods. [ABSTRACT FROM AUTHOR]
Copyright of Communications Engineer is the property of Institution of Engineering & Technology and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 20330924
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: EMC above 1 GHz [electromagnetic compatibility].
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Marshall%2C+R%2E%22">Marshall, R.</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Communications+Engineer%22">Communications Engineer</searchLink>. Feb2006, Vol. 4 Issue 1, p30-33. 4p. 5 Color Photographs.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Electromagnetic+compatibility%22">Electromagnetic compatibility</searchLink><br /><searchLink fieldCode="DE" term="%22Communication+in+engineering%22">Communication in engineering</searchLink><br /><searchLink fieldCode="DE" term="%22Frequency+changers%22">Frequency changers</searchLink><br /><searchLink fieldCode="DE" term="%22Physics%22">Physics</searchLink><br /><searchLink fieldCode="DE" term="%22Industrial+research%22">Industrial research</searchLink><br /><searchLink fieldCode="DE" term="%22Radio+frequency%22">Radio frequency</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: While the need for electromagnetic compatibility (EMC) above 1 GHz has been long appreciated by the military, it has recently become of wide concern. The upward march of computer clock frequencies and the massive deployment of radio users of these frequencies have fueled this concern. There has always been difficulties in dealing with physically large equipments and the need to establish testing of everyday electronics above 1 GHz has brought objects into the "large compared with a wavelength" category. In this paper, the author discussed the increasing importance of electromagnetic compatibility at higher frequencies. All the presented discussions apply to the traditional "open area test site" which has been adopted by CISPR. At the seminar, opinions were divided on the wisdom of CISPR's choice of traditional test methods. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Communications Engineer is the property of Institution of Engineering & Technology and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=20330924
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1049/ce:20060104
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 4
        StartPage: 30
    Subjects:
      – SubjectFull: Electromagnetic compatibility
        Type: general
      – SubjectFull: Communication in engineering
        Type: general
      – SubjectFull: Frequency changers
        Type: general
      – SubjectFull: Physics
        Type: general
      – SubjectFull: Industrial research
        Type: general
      – SubjectFull: Radio frequency
        Type: general
    Titles:
      – TitleFull: EMC above 1 GHz [electromagnetic compatibility].
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Marshall, R.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 02
              Text: Feb2006
              Type: published
              Y: 2006
          Identifiers:
            – Type: issn-print
              Value: 14798352
          Numbering:
            – Type: volume
              Value: 4
            – Type: issue
              Value: 1
          Titles:
            – TitleFull: Communications Engineer
              Type: main
ResultId 1