Title: Application of MLE method to range determination with induced β+ activity in hadron therapy
Authors: Inaniwa, T.1, Kohno, T.1 kohno@es.titech.ac.jp, Tomitani, T.2, Kanazawa, M.2, Sato, S.2, Urakabe, E.3, Kanai, T.3
Source: Nuclear Instruments & Methods in Physics Research Section A. Jun2006, Vol. 562 Issue 2, p1017-1019. 3p.
Subjects: Ions, Irradiation, Electrons, Properties of matter
Abstract: Abstract: We proposed to apply the MLE method for determining the range of heavy ions and demonstrated the effectiveness of this method by experiments with 12C beams. We performed irradiation experiments with stable 12C ions of mono-energetic 290MeV/u to a water, a polyethylene and a PMMA target. The theoretical ranges for 12C ions of 290MeV/u in these targets are 160.5, 157.9 and 139.8mm, respectively. The annihilation events from positron emitters generated by 12C ions were detected with a positron camera for 500s just after the irradiation. To evaluate the range of 12C ions, the MLE method was applied to the annihilation gamma ray distribution. The derived ranges for the three targets were 160.6, 158.9 and 140.4mm, respectively. Therefore, we can conclude that the range of 12C ions was determined within an accuracy of 1.0mm for all targets. [Copyright &y& Elsevier]
Copyright of Nuclear Instruments & Methods in Physics Research Section A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 21253152
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Application of MLE method to range determination with induced β<superscript>+</superscript> activity in hadron therapy
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Inaniwa%2C+T%2E%22">Inaniwa, T.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Kohno%2C+T%2E%22">Kohno, T.</searchLink><relatesTo>1</relatesTo><i> kohno@es.titech.ac.jp</i><br /><searchLink fieldCode="AR" term="%22Tomitani%2C+T%2E%22">Tomitani, T.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Kanazawa%2C+M%2E%22">Kanazawa, M.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Sato%2C+S%2E%22">Sato, S.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Urakabe%2C+E%2E%22">Urakabe, E.</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Kanai%2C+T%2E%22">Kanai, T.</searchLink><relatesTo>3</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Nuclear+Instruments+%26+Methods+in+Physics+Research+Section+A%22">Nuclear Instruments & Methods in Physics Research Section A</searchLink>. Jun2006, Vol. 562 Issue 2, p1017-1019. 3p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Ions%22">Ions</searchLink><br /><searchLink fieldCode="DE" term="%22Irradiation%22">Irradiation</searchLink><br /><searchLink fieldCode="DE" term="%22Electrons%22">Electrons</searchLink><br /><searchLink fieldCode="DE" term="%22Properties+of+matter%22">Properties of matter</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Abstract: We proposed to apply the MLE method for determining the range of heavy ions and demonstrated the effectiveness of this method by experiments with 12C beams. We performed irradiation experiments with stable 12C ions of mono-energetic 290MeV/u to a water, a polyethylene and a PMMA target. The theoretical ranges for 12C ions of 290MeV/u in these targets are 160.5, 157.9 and 139.8mm, respectively. The annihilation events from positron emitters generated by 12C ions were detected with a positron camera for 500s just after the irradiation. To evaluate the range of 12C ions, the MLE method was applied to the annihilation gamma ray distribution. The derived ranges for the three targets were 160.6, 158.9 and 140.4mm, respectively. Therefore, we can conclude that the range of 12C ions was determined within an accuracy of 1.0mm for all targets. [Copyright &y& Elsevier]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Nuclear Instruments & Methods in Physics Research Section A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=21253152
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.nima.2006.02.085
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 3
        StartPage: 1017
    Subjects:
      – SubjectFull: Ions
        Type: general
      – SubjectFull: Irradiation
        Type: general
      – SubjectFull: Electrons
        Type: general
      – SubjectFull: Properties of matter
        Type: general
    Titles:
      – TitleFull: Application of MLE method to range determination with induced β+ activity in hadron therapy
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Inaniwa, T.
      – PersonEntity:
          Name:
            NameFull: Kohno, T.
      – PersonEntity:
          Name:
            NameFull: Tomitani, T.
      – PersonEntity:
          Name:
            NameFull: Kanazawa, M.
      – PersonEntity:
          Name:
            NameFull: Sato, S.
      – PersonEntity:
          Name:
            NameFull: Urakabe, E.
      – PersonEntity:
          Name:
            NameFull: Kanai, T.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 23
              M: 06
              Text: Jun2006
              Type: published
              Y: 2006
          Identifiers:
            – Type: issn-print
              Value: 01689002
          Numbering:
            – Type: volume
              Value: 562
            – Type: issue
              Value: 2
          Titles:
            – TitleFull: Nuclear Instruments & Methods in Physics Research Section A
              Type: main
ResultId 1