Determination of trace elements in seawater samples by on-line column extraction/graphite furnace atomic absorption spectrometry

Saved in:
Bibliographic Details
Title: Determination of trace elements in seawater samples by on-line column extraction/graphite furnace atomic absorption spectrometry
Authors: Ceccarini, A. alessio@dcci.unipi.it, Cecchini, I.1, Fuoco, R.1
Source: Microchemical Journal. Jan2005, Vol. 79 Issue 1/2, p21-24. 4p.
Subjects: Saline waters, Carbon, Agricultural chemicals, Atomic absorption spectroscopy
Abstract: Abstract: An innovative procedure for the on-line coupling of ion chromatography with graphite furnace atomic absorption spectrometry is described, which is particularly effective for the determination of trace metals in seawater samples. The Capillary Injection Device (CID) is used as an interface which allows the eluent to be transferred from the chromatographic column into the graphite tube at a flow rate of as high as 2 ml/min. The analytical procedure is based on the metal complex formation with 8-hydroxyquinoline in the sample solution, followed by the preconcentration of the complexes in a chromatographic column packed with XAD-2 resin. The complexes were then eluted from the column with methanol, and quantitatively injected into the furnace. The procedure was validated by determining cadmium and lead in certified reference seawater samples at a level of 30–40 pg/g, with a typical reproducibility of 10% and an accuracy of better than 5%. Finally, it was tested on a real sample of seawater. Due to the high reproducibility, a pg/g concentration level can be measured. [Copyright &y& Elsevier]
Copyright of Microchemical Journal is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 22229598
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Determination of trace elements in seawater samples by on-line column extraction/graphite furnace atomic absorption spectrometry
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Ceccarini%2C+A%2E%22">Ceccarini, A.</searchLink><i> alessio@dcci.unipi.it</i><br /><searchLink fieldCode="AR" term="%22Cecchini%2C+I%2E%22">Cecchini, I.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Fuoco%2C+R%2E%22">Fuoco, R.</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Microchemical+Journal%22">Microchemical Journal</searchLink>. Jan2005, Vol. 79 Issue 1/2, p21-24. 4p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Saline+waters%22">Saline waters</searchLink><br /><searchLink fieldCode="DE" term="%22Carbon%22">Carbon</searchLink><br /><searchLink fieldCode="DE" term="%22Agricultural+chemicals%22">Agricultural chemicals</searchLink><br /><searchLink fieldCode="DE" term="%22Atomic+absorption+spectroscopy%22">Atomic absorption spectroscopy</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Abstract: An innovative procedure for the on-line coupling of ion chromatography with graphite furnace atomic absorption spectrometry is described, which is particularly effective for the determination of trace metals in seawater samples. The Capillary Injection Device (CID) is used as an interface which allows the eluent to be transferred from the chromatographic column into the graphite tube at a flow rate of as high as 2 ml/min. The analytical procedure is based on the metal complex formation with 8-hydroxyquinoline in the sample solution, followed by the preconcentration of the complexes in a chromatographic column packed with XAD-2 resin. The complexes were then eluted from the column with methanol, and quantitatively injected into the furnace. The procedure was validated by determining cadmium and lead in certified reference seawater samples at a level of 30–40 pg/g, with a typical reproducibility of 10% and an accuracy of better than 5%. Finally, it was tested on a real sample of seawater. Due to the high reproducibility, a pg/g concentration level can be measured. [Copyright &y& Elsevier]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Microchemical Journal is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=22229598
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.microc.2004.10.020
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 4
        StartPage: 21
    Subjects:
      – SubjectFull: Saline waters
        Type: general
      – SubjectFull: Carbon
        Type: general
      – SubjectFull: Agricultural chemicals
        Type: general
      – SubjectFull: Atomic absorption spectroscopy
        Type: general
    Titles:
      – TitleFull: Determination of trace elements in seawater samples by on-line column extraction/graphite furnace atomic absorption spectrometry
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Ceccarini, A.
      – PersonEntity:
          Name:
            NameFull: Cecchini, I.
      – PersonEntity:
          Name:
            NameFull: Fuoco, R.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 01
              Text: Jan2005
              Type: published
              Y: 2005
          Identifiers:
            – Type: issn-print
              Value: 0026265X
          Numbering:
            – Type: volume
              Value: 79
            – Type: issue
              Value: 1/2
          Titles:
            – TitleFull: Microchemical Journal
              Type: main
ResultId 1