Radiation effects on ALICE V0 detector components

Saved in:
Bibliographic Details
Title: Radiation effects on ALICE V0 detector components
Authors: Cheynis, B.1, Ducroux, L.1, Grossiord, J.-Y. j-y.grossiord@ipnl.in2p3.fr, Guichard, A.1, Pillot, P.1, Rapp, B.1, Tieulent, R.1, Tromeur, W.1, Zoccarato, Y.1
Source: Nuclear Instruments & Methods in Physics Research Section A. Dec2006, Vol. 569 Issue 3, p732-736. 5p.
Subjects: Optical waveguides, Engineering instruments, Fiber optics, Optical materials
Abstract: Abstract: The 60MeV proton beam delivered by the RADEF facility of the University of Jyväskylä (Finland) was used to measure the radiation effects on the counter components of the V0 detector of ALICE. There are the scintillator BC404, the wavelength shifting fibres BCF9929A and the optical fibres BCF98 from Bicron (Saint-Gobain). The light yield and the time resolution given by a counter of the inner ring of the V0C array, mounted within a dedicated device, were measured as a function of the radiation dose up to about 300krad. A global light attenuation of the order of 30% can be anticipated during 10 years of ALICE running. [Copyright &y& Elsevier]
Copyright of Nuclear Instruments & Methods in Physics Research Section A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:Abstract: The 60MeV proton beam delivered by the RADEF facility of the University of Jyväskylä (Finland) was used to measure the radiation effects on the counter components of the V0 detector of ALICE. There are the scintillator BC404, the wavelength shifting fibres BCF9929A and the optical fibres BCF98 from Bicron (Saint-Gobain). The light yield and the time resolution given by a counter of the inner ring of the V0C array, mounted within a dedicated device, were measured as a function of the radiation dose up to about 300krad. A global light attenuation of the order of 30% can be anticipated during 10 years of ALICE running. [Copyright &y& Elsevier]
ISSN:01689002
DOI:10.1016/j.nima.2006.09.086