Development of a new diagnostic method for galactosemia by high-performance anion-exchange chromatography with pulsed amperometric detection

Saved in:
Bibliographic Details
Title: Development of a new diagnostic method for galactosemia by high-performance anion-exchange chromatography with pulsed amperometric detection
Authors: Jeong, Ji-Seon1, Yoon, Hye-Ran2, Hong, Seon-Pyo1 seonhong@khu.ac.kr
Source: Journal of Chromatography A. Jan2007, Vol. 1140 Issue 1/2, p157-162. 6p.
Subjects: Galactosemia, Chromatographic analysis, Conductometric analysis, Galactose
Abstract: Abstract: We developed a new non-derivatization analytical method for the determination of galactose in the diagnosis of galactosemia by high-performance anion-exchange chromatography (HPAEC)-pulsed amperometric detection (PAD). With an anion-exchange column, the analytes were separated efficiently using 3mM NaOH containing 1mM NaOAc, and 200mM NaOH was added for post-column reagent. The limit of detection (S/N=3) and limit of quantification (S/N=10) for galactose were 25ng/mL and 83ng/mL, respectively. Linear dynamic range was from 4.67mg/dL to 53.46mg/dL (r 2 =0.9999). The mean recovery of galactose for intra-, inter-day assays were found to be of satisfactory results (98.14–101.42%). [Copyright &y& Elsevier]
Copyright of Journal of Chromatography A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:Abstract: We developed a new non-derivatization analytical method for the determination of galactose in the diagnosis of galactosemia by high-performance anion-exchange chromatography (HPAEC)-pulsed amperometric detection (PAD). With an anion-exchange column, the analytes were separated efficiently using 3mM NaOH containing 1mM NaOAc, and 200mM NaOH was added for post-column reagent. The limit of detection (S/N=3) and limit of quantification (S/N=10) for galactose were 25ng/mL and 83ng/mL, respectively. Linear dynamic range was from 4.67mg/dL to 53.46mg/dL (r 2 =0.9999). The mean recovery of galactose for intra-, inter-day assays were found to be of satisfactory results (98.14–101.42%). [Copyright &y& Elsevier]
ISSN:00219673