Hair analysis for methamphetamine, ketamine, morphine and codeine by cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography

Saved in:
Bibliographic Details
Title: Hair analysis for methamphetamine, ketamine, morphine and codeine by cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography
Authors: Lin, Yi-Hui1, Lee, Maw-Rong2, Lee, Ren-Jye2, Ko, Wei-Kung3, Wu, Shou-Mei1,4,5 shmewu@kmu.edu.tw
Source: Journal of Chromatography A. Mar2007, Vol. 1145 Issue 1/2, p234-240. 7p.
Subjects: Drug abuse, Ketamine, Cations, Chromatographic analysis
Abstract: Abstract: We established a capillary electrophoretic method with high sensitivity and specificity for testing hair taken from addicts. After pretreatment of hair sample, the cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography (CSEI-Sweep-MEKC) was used to test for the presence of abused drugs in human hair. These drugs include morphine (M), codeine (C), ketamine (K) and methamphetamine (MA). First, an uncoated fused-silica capillary (40cm, 50μm I.D.) was filled with phosphate buffer (50mM, pH 2.5) containing 30% methanol, followed by high conductivity buffer (100mM phosphate, 6.9kPa for 99.9s). Electrokinetic injection (10kV, 600s) was used to load samples and to enhance sensitivity. Stacking steps and separations were performed at −20kV with detection at 200nm, using phosphate buffer (25mM, pH 2.5) containing 20% methanol and 100mM sodium dodecyl sulfate. Using CSEI-Sweep-MEKC, the analytes could be simultaneously analyzed and have a detection limit down to the level of picogram per milligram hair. During method validation, calibration plots were linear (r ≥0.999) over a range of 0.15–80ng/mg hair for MA and K, 0.3–30ng/mg hair for C and 0.5–50ng/mg hair for M. The limits of detection were 50pg/mg hair for MA and K, 100pg/mg hair for C and 200pg/mg hair for M (S/N=3, sampling 600s at 10kV). Our method was applied for analysis of real hair samples taken from addicts. The addicts’ specimens were also analyzed by LC–MS, and showed good coincidence of results. This method has proven feasible for application in detecting trace levels of abused drugs in forensic analysis. [Copyright &y& Elsevier]
Copyright of Journal of Chromatography A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Be the first to leave a comment!
You must be logged in first