Minute Volumes and Inspiratory Flow Rates During Exhaustive Treadmill Walking Using Respirators.

Saved in:
Bibliographic Details
Title: Minute Volumes and Inspiratory Flow Rates During Exhaustive Treadmill Walking Using Respirators.
Authors: INGVAR HOLMéR, KALEV KUKLANE, CHUANSI GAO
Source: Annals of Occupational Hygiene. May2007, Vol. 51 Issue 3, p327-327. 1p.
Subjects: Treadmill exercise, Breathing apparatus, Mechanical ventilators, Protective coverings
Abstract: Air flow rate through filters and face masks is one important determinant of the final protection factor of a respiratory protective device in use. Respiratory minute volumes and instantaneous breath flow rates were measured in eight subjects during treadmill work using three types of filtering respirators and one control breathing mask. Work comprised five consecutive bouts of walking at 5 km/h with an increase in elevation of the treadmill by 5% every 5 min and a final walk at 6 km/h and 22.5%. Three subjects managed to complete 5 min at the final work rate. Minute ventilation increased in a curvilinear manner with oxygen uptake and reached 88 ± 20 and 93 ± 20 l/min at 5 km/h (20%) with the control mask and a half mask with filter (SP), respectively. Mean peak inspiratory flow rate (PIFR) was 273 ± 39 for Control and 300 ± 36 for SP at the same work rate. Two power assisted, positive pressure filter respirators (SA and SE) produced higher mask minute volumes at any given work rate compared to respiratory minute volumes in control and SP. PIFR in SA and SE were equal to or lesser than SP. During standardized speech communication, minute volumes decreased. In contrast, PIFR increased by about 100% at low work rates and about 30% at 5 km/h (20%) compared to no speech condition, reaching a highest value of 414 ± 46 l/min for SE. Filter testing is made at a constant flow rate of 95 l/min, a condition that eventually needs to be reconsidered in order to ensure a relevant and valid function test. [ABSTRACT FROM AUTHOR]
Copyright of Annals of Occupational Hygiene is the property of Oxford University Press / USA and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 25208290
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Minute Volumes and Inspiratory Flow Rates During Exhaustive Treadmill Walking Using Respirators.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22INGVAR+HOLMéR%22">INGVAR HOLMéR</searchLink><br /><searchLink fieldCode="AR" term="%22KALEV+KUKLANE%22">KALEV KUKLANE</searchLink><br /><searchLink fieldCode="AR" term="%22CHUANSI+GAO%22">CHUANSI GAO</searchLink>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Annals+of+Occupational+Hygiene%22">Annals of Occupational Hygiene</searchLink>. May2007, Vol. 51 Issue 3, p327-327. 1p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Treadmill+exercise%22">Treadmill exercise</searchLink><br /><searchLink fieldCode="DE" term="%22Breathing+apparatus%22">Breathing apparatus</searchLink><br /><searchLink fieldCode="DE" term="%22Mechanical+ventilators%22">Mechanical ventilators</searchLink><br /><searchLink fieldCode="DE" term="%22Protective+coverings%22">Protective coverings</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Air flow rate through filters and face masks is one important determinant of the final protection factor of a respiratory protective device in use. Respiratory minute volumes and instantaneous breath flow rates were measured in eight subjects during treadmill work using three types of filtering respirators and one control breathing mask. Work comprised five consecutive bouts of walking at 5 km/h with an increase in elevation of the treadmill by 5% every 5 min and a final walk at 6 km/h and 22.5%. Three subjects managed to complete 5 min at the final work rate. Minute ventilation increased in a curvilinear manner with oxygen uptake and reached 88 ± 20 and 93 ± 20 l/min at 5 km/h (20%) with the control mask and a half mask with filter (SP), respectively. Mean peak inspiratory flow rate (PIFR) was 273 ± 39 for Control and 300 ± 36 for SP at the same work rate. Two power assisted, positive pressure filter respirators (SA and SE) produced higher mask minute volumes at any given work rate compared to respiratory minute volumes in control and SP. PIFR in SA and SE were equal to or lesser than SP. During standardized speech communication, minute volumes decreased. In contrast, PIFR increased by about 100% at low work rates and about 30% at 5 km/h (20%) compared to no speech condition, reaching a highest value of 414 ± 46 l/min for SE. Filter testing is made at a constant flow rate of 95 l/min, a condition that eventually needs to be reconsidered in order to ensure a relevant and valid function test. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Annals of Occupational Hygiene is the property of Oxford University Press / USA and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=25208290
RecordInfo BibRecord:
  BibEntity:
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 1
        StartPage: 327
    Subjects:
      – SubjectFull: Treadmill exercise
        Type: general
      – SubjectFull: Breathing apparatus
        Type: general
      – SubjectFull: Mechanical ventilators
        Type: general
      – SubjectFull: Protective coverings
        Type: general
    Titles:
      – TitleFull: Minute Volumes and Inspiratory Flow Rates During Exhaustive Treadmill Walking Using Respirators.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: INGVAR HOLMéR
      – PersonEntity:
          Name:
            NameFull: KALEV KUKLANE
      – PersonEntity:
          Name:
            NameFull: CHUANSI GAO
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 11
              M: 05
              Text: May2007
              Type: published
              Y: 2007
          Identifiers:
            – Type: issn-print
              Value: 00034878
          Numbering:
            – Type: volume
              Value: 51
            – Type: issue
              Value: 3
          Titles:
            – TitleFull: Annals of Occupational Hygiene
              Type: main
ResultId 1