Performance comparison of two commercial BGO-based PET/CT scanners using NEMA NU 2-2001.
Saved in:
| Title: | Performance comparison of two commercial BGO-based PET/CT scanners using NEMA NU 2-2001. |
|---|---|
| Authors: | Bolard, Grégory1, Prior, John O.2, Modolo, Luca3, Bischof Delaloye, Angelika2, Kosinski, Marek3, Wastiel, Claude1, Malterre, Jérôme2, Bulling, Shelley1, Bochud, François1, Verdun, Francis R.1 |
| Source: | Medical Physics. Jul2007, Vol. 34 Issue 7, p2708-2717. 10p. 1 Diagram, 7 Charts, 6 Graphs. |
| Subjects: | Positron emission tomography, Diagnostic imaging, Medical electronics, Medical radiology, Medical imaging systems, Scanning systems |
| Abstract: | Combined positron emission tomography and computed tomography (PET/CT) scanners play a major role in medicine for in vivo imaging in an increasing number of diseases in oncology, cardiology, neurology, and psychiatry. With the advent of short-lived radioisotopes other than 18F and newer scanners, there is a need to optimize radioisotope activity and acquisition protocols, as well as to compare scanner performances on an objective basis. The Discovery-LS (D-LS) was among the first clinical PET/CT scanners to be developed and has been extensively characterized with older National Electrical Manufacturer Association (NEMA) NU 2-1994 standards. At the time of publication of the latest version of the standards (NU 2-2001) that have been adapted for whole-body imaging under clinical conditions, more recent models from the same manufacturer, i.e., Discovery-ST (D-ST) and Discovery-STE (D-STE), were commercially available. We report on the full characterization both in the two- and three-dimensional acquisition mode of the D-LS according to latest NEMA NU 2-2001 standards (spatial resolution, sensitivity, count rate performance, accuracy of count losses, and random coincidence correction and image quality), as well as a detailed comparison with the newer D-ST widely used and whose characteristics are already published. [ABSTRACT FROM AUTHOR] |
| Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Links: – Type: pdflink Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 25638954 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Performance comparison of two commercial BGO-based PET/CT scanners using NEMA NU 2-2001. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Bolard%2C+Grégory%22">Bolard, Grégory</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Prior%2C+John+O%2E%22">Prior, John O.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Modolo%2C+Luca%22">Modolo, Luca</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Bischof+Delaloye%2C+Angelika%22">Bischof Delaloye, Angelika</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Kosinski%2C+Marek%22">Kosinski, Marek</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Wastiel%2C+Claude%22">Wastiel, Claude</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Malterre%2C+Jérôme%22">Malterre, Jérôme</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Bulling%2C+Shelley%22">Bulling, Shelley</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Bochud%2C+François%22">Bochud, François</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Verdun%2C+Francis+R%2E%22">Verdun, Francis R.</searchLink><relatesTo>1</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Jul2007, Vol. 34 Issue 7, p2708-2717. 10p. 1 Diagram, 7 Charts, 6 Graphs. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Positron+emission+tomography%22">Positron emission tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Diagnostic+imaging%22">Diagnostic imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+electronics%22">Medical electronics</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+radiology%22">Medical radiology</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+imaging+systems%22">Medical imaging systems</searchLink><br /><searchLink fieldCode="DE" term="%22Scanning+systems%22">Scanning systems</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Combined positron emission tomography and computed tomography (PET/CT) scanners play a major role in medicine for in vivo imaging in an increasing number of diseases in oncology, cardiology, neurology, and psychiatry. With the advent of short-lived radioisotopes other than 18F and newer scanners, there is a need to optimize radioisotope activity and acquisition protocols, as well as to compare scanner performances on an objective basis. The Discovery-LS (D-LS) was among the first clinical PET/CT scanners to be developed and has been extensively characterized with older National Electrical Manufacturer Association (NEMA) NU 2-1994 standards. At the time of publication of the latest version of the standards (NU 2-2001) that have been adapted for whole-body imaging under clinical conditions, more recent models from the same manufacturer, i.e., Discovery-ST (D-ST) and Discovery-STE (D-STE), were commercially available. We report on the full characterization both in the two- and three-dimensional acquisition mode of the D-LS according to latest NEMA NU 2-2001 standards (spatial resolution, sensitivity, count rate performance, accuracy of count losses, and random coincidence correction and image quality), as well as a detailed comparison with the newer D-ST widely used and whose characteristics are already published. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=25638954 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1118/1.2739808 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 10 StartPage: 2708 Subjects: – SubjectFull: Positron emission tomography Type: general – SubjectFull: Diagnostic imaging Type: general – SubjectFull: Medical electronics Type: general – SubjectFull: Medical radiology Type: general – SubjectFull: Medical imaging systems Type: general – SubjectFull: Scanning systems Type: general Titles: – TitleFull: Performance comparison of two commercial BGO-based PET/CT scanners using NEMA NU 2-2001. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Bolard, Grégory – PersonEntity: Name: NameFull: Prior, John O. – PersonEntity: Name: NameFull: Modolo, Luca – PersonEntity: Name: NameFull: Bischof Delaloye, Angelika – PersonEntity: Name: NameFull: Kosinski, Marek – PersonEntity: Name: NameFull: Wastiel, Claude – PersonEntity: Name: NameFull: Malterre, Jérôme – PersonEntity: Name: NameFull: Bulling, Shelley – PersonEntity: Name: NameFull: Bochud, François – PersonEntity: Name: NameFull: Verdun, Francis R. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 07 Text: Jul2007 Type: published Y: 2007 Identifiers: – Type: issn-print Value: 00942405 Numbering: – Type: volume Value: 34 – Type: issue Value: 7 Titles: – TitleFull: Medical Physics Type: main |
| ResultId | 1 |