Performance comparison of two commercial BGO-based PET/CT scanners using NEMA NU 2-2001.

Saved in:
Bibliographic Details
Title: Performance comparison of two commercial BGO-based PET/CT scanners using NEMA NU 2-2001.
Authors: Bolard, Grégory1, Prior, John O.2, Modolo, Luca3, Bischof Delaloye, Angelika2, Kosinski, Marek3, Wastiel, Claude1, Malterre, Jérôme2, Bulling, Shelley1, Bochud, François1, Verdun, Francis R.1
Source: Medical Physics. Jul2007, Vol. 34 Issue 7, p2708-2717. 10p. 1 Diagram, 7 Charts, 6 Graphs.
Subjects: Positron emission tomography, Diagnostic imaging, Medical electronics, Medical radiology, Medical imaging systems, Scanning systems
Abstract: Combined positron emission tomography and computed tomography (PET/CT) scanners play a major role in medicine for in vivo imaging in an increasing number of diseases in oncology, cardiology, neurology, and psychiatry. With the advent of short-lived radioisotopes other than 18F and newer scanners, there is a need to optimize radioisotope activity and acquisition protocols, as well as to compare scanner performances on an objective basis. The Discovery-LS (D-LS) was among the first clinical PET/CT scanners to be developed and has been extensively characterized with older National Electrical Manufacturer Association (NEMA) NU 2-1994 standards. At the time of publication of the latest version of the standards (NU 2-2001) that have been adapted for whole-body imaging under clinical conditions, more recent models from the same manufacturer, i.e., Discovery-ST (D-ST) and Discovery-STE (D-STE), were commercially available. We report on the full characterization both in the two- and three-dimensional acquisition mode of the D-LS according to latest NEMA NU 2-2001 standards (spatial resolution, sensitivity, count rate performance, accuracy of count losses, and random coincidence correction and image quality), as well as a detailed comparison with the newer D-ST widely used and whose characteristics are already published. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Be the first to leave a comment!
You must be logged in first