CT colonography: optimisation, diagnostic performance and patient acceptability of reduced-laxative regimens using barium-based faecal tagging.
Saved in:
| Title: | CT colonography: optimisation, diagnostic performance and patient acceptability of reduced-laxative regimens using barium-based faecal tagging. |
|---|---|
| Authors: | Taylor, Stuart csytaylor@yahoo.co.uk, Slater, Andrew1, Burling, David2, Tam, Emily2, Greenhalgh, Rebecca3, Gartner, Louise2, Scarth, Julia2, Pearce, Robert3, Bassett, Paul2, Halligan, Steve3 |
| Source: | European Radiology. Jan2008, Vol. 18 Issue 1, p32-42. 11p. 5 Black and White Photographs, 6 Charts, 1 Graph. |
| Subjects: | Colon radiography, Randomized controlled trials, Colonoscopy, Laxatives, Barium sulfate, Drug administration |
| Abstract: | To establish the optimum barium-based reduced-laxative tagging regimen prior to CT colonography (CTC). Ninety-five subjects underwent reduced-laxative (13 g senna/18 g magnesium citrate) CTC prior to same-day colonoscopy and were randomised to one of four tagging regimens using 20 ml 40%w/v barium sulphate: regimen A: four doses, B: three doses, C: three doses plus 220 ml 2.1% barium sulphate, or D: three doses plus 15 ml diatriazoate megluamine. Patient experience was assessed immediately after CTC and 1 week later. Two radiologists graded residual stool (1: none/scattered to 4: >50% circumference) and tagging efficacy for stool (1: untagged to 5: 100% tagged) and fluid (1: untagged, 2: layered, 3: tagged), noting the HU of tagged fluid. Preparation was good (76–94% segments graded 1), although best for regimen D ( P = 0.02). Across all regimens, stool tagging quality was high (mean 3.7–4.5) and not significantly different among regimens. The HU of layered tagged fluid was higher for regimens C/D than A/B ( P = 0.002). Detection of cancer ( n = 2), polyps ≥6 mm ( n = 21), and ≤5 mm ( n = 72) was 100, 81 and 32% respectively, with only four false positives ≥6 mm. Reduced preparation was tolerated better than full endoscopic preparation by 61%. Reduced-laxative CTC with three doses of 20 ml 40% barium sulphate is as effective as more complex regimens, retaining adequate diagnostic accuracy. [ABSTRACT FROM AUTHOR] |
| Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Links: – Type: pdflink Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 28716092 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: CT colonography: optimisation, diagnostic performance and patient acceptability of reduced-laxative regimens using barium-based faecal tagging. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Taylor%2C+Stuart%22">Taylor, Stuart</searchLink><i> csytaylor@yahoo.co.uk</i><br /><searchLink fieldCode="AR" term="%22Slater%2C+Andrew%22">Slater, Andrew</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Burling%2C+David%22">Burling, David</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Tam%2C+Emily%22">Tam, Emily</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Greenhalgh%2C+Rebecca%22">Greenhalgh, Rebecca</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Gartner%2C+Louise%22">Gartner, Louise</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Scarth%2C+Julia%22">Scarth, Julia</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Pearce%2C+Robert%22">Pearce, Robert</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Bassett%2C+Paul%22">Bassett, Paul</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Halligan%2C+Steve%22">Halligan, Steve</searchLink><relatesTo>3</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22European+Radiology%22">European Radiology</searchLink>. Jan2008, Vol. 18 Issue 1, p32-42. 11p. 5 Black and White Photographs, 6 Charts, 1 Graph. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Colon+radiography%22">Colon radiography</searchLink><br /><searchLink fieldCode="DE" term="%22Randomized+controlled+trials%22">Randomized controlled trials</searchLink><br /><searchLink fieldCode="DE" term="%22Colonoscopy%22">Colonoscopy</searchLink><br /><searchLink fieldCode="DE" term="%22Laxatives%22">Laxatives</searchLink><br /><searchLink fieldCode="DE" term="%22Barium+sulfate%22">Barium sulfate</searchLink><br /><searchLink fieldCode="DE" term="%22Drug+administration%22">Drug administration</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: To establish the optimum barium-based reduced-laxative tagging regimen prior to CT colonography (CTC). Ninety-five subjects underwent reduced-laxative (13 g senna/18 g magnesium citrate) CTC prior to same-day colonoscopy and were randomised to one of four tagging regimens using 20 ml 40%w/v barium sulphate: regimen A: four doses, B: three doses, C: three doses plus 220 ml 2.1% barium sulphate, or D: three doses plus 15 ml diatriazoate megluamine. Patient experience was assessed immediately after CTC and 1 week later. Two radiologists graded residual stool (1: none/scattered to 4: >50% circumference) and tagging efficacy for stool (1: untagged to 5: 100% tagged) and fluid (1: untagged, 2: layered, 3: tagged), noting the HU of tagged fluid. Preparation was good (76–94% segments graded 1), although best for regimen D ( P = 0.02). Across all regimens, stool tagging quality was high (mean 3.7–4.5) and not significantly different among regimens. The HU of layered tagged fluid was higher for regimens C/D than A/B ( P = 0.002). Detection of cancer ( n = 2), polyps ≥6 mm ( n = 21), and ≤5 mm ( n = 72) was 100, 81 and 32% respectively, with only four false positives ≥6 mm. Reduced preparation was tolerated better than full endoscopic preparation by 61%. Reduced-laxative CTC with three doses of 20 ml 40% barium sulphate is as effective as more complex regimens, retaining adequate diagnostic accuracy. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=28716092 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1007/s00330-007-0631-0 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 11 StartPage: 32 Subjects: – SubjectFull: Colon radiography Type: general – SubjectFull: Randomized controlled trials Type: general – SubjectFull: Colonoscopy Type: general – SubjectFull: Laxatives Type: general – SubjectFull: Barium sulfate Type: general – SubjectFull: Drug administration Type: general Titles: – TitleFull: CT colonography: optimisation, diagnostic performance and patient acceptability of reduced-laxative regimens using barium-based faecal tagging. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Taylor, Stuart – PersonEntity: Name: NameFull: Slater, Andrew – PersonEntity: Name: NameFull: Burling, David – PersonEntity: Name: NameFull: Tam, Emily – PersonEntity: Name: NameFull: Greenhalgh, Rebecca – PersonEntity: Name: NameFull: Gartner, Louise – PersonEntity: Name: NameFull: Scarth, Julia – PersonEntity: Name: NameFull: Pearce, Robert – PersonEntity: Name: NameFull: Bassett, Paul – PersonEntity: Name: NameFull: Halligan, Steve IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 01 Text: Jan2008 Type: published Y: 2008 Identifiers: – Type: issn-print Value: 09387994 Numbering: – Type: volume Value: 18 – Type: issue Value: 1 Titles: – TitleFull: European Radiology Type: main |
| ResultId | 1 |