Title: Design study of a rotating gantry for the HIMAC new treatment facility
Authors: Furukawa, T. t_furu@nirs.go.jp, Inaniwa, T.1, Sato, S.1, Iwata, Y.1, Fujimoto, T.1, Minohara, S.1, Noda, K.1, Kanai, T.1
Source: Nuclear Instruments & Methods in Physics Research Section B. May2008, Vol. 266 Issue 10, p2186-2189. 4p.
Subjects: Carbon, Ions, Therapeutics, Irradiation
Abstract: Abstract: A project to construct a new treatment facility as an extension of the existing HIMAC facility has been initiated for the further development of carbon-ion therapy. In the new facility, one of the treatment rooms will be equipped with an iso-centric gantry system employing a 3D pencil beam scanning irradiation method. In order to realize a compact design, the final 90° bending magnet is divided into two bending magnets of 60° and 30°. The scanning magnets are set between these two bending magnets, although the aperture of the 30° magnet increases. Finally, we achieved 350 tons of total weight for 400MeV/u carbon beams with a 150mm square field. [Copyright &y& Elsevier]
Copyright of Nuclear Instruments & Methods in Physics Research Section B is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:Abstract: A project to construct a new treatment facility as an extension of the existing HIMAC facility has been initiated for the further development of carbon-ion therapy. In the new facility, one of the treatment rooms will be equipped with an iso-centric gantry system employing a 3D pencil beam scanning irradiation method. In order to realize a compact design, the final 90° bending magnet is divided into two bending magnets of 60° and 30°. The scanning magnets are set between these two bending magnets, although the aperture of the 30° magnet increases. Finally, we achieved 350 tons of total weight for 400MeV/u carbon beams with a 150mm square field. [Copyright &y& Elsevier]
ISSN:0168583X
DOI:10.1016/j.nimb.2008.02.078