Sensitive Terbium Probes for Luminescent Determination of both Alkaline Phosphatase and Codeine Phosphate.
Saved in:
| Title: | Sensitive Terbium Probes for Luminescent Determination of both Alkaline Phosphatase and Codeine Phosphate. |
|---|---|
| Authors: | Duerkop, Axel1 (AUTHOR), Aleksandrova, Darya2 (AUTHOR), Scripinets, Yuliya2 (AUTHOR), Yegorova, Alla1,2 (AUTHOR), Vityukova, Ekateryna2 (AUTHOR) |
| Source: | Annals of the New York Academy of Sciences. May2008, Vol. 1130, p172-178. 7p. 1 Diagram, 4 Charts, 1 Graph. |
| Subjects: | Semiconductor analysis, Alkaline phosphatase, Carbonyl compounds, Ligands (Biochemistry), Electronic excitation, Metal quenching, Metal ions, Spectrum analysis, Scientific method |
| Abstract: | New terbium complexes of 2-oxo-4-hydroxy-quinoline-3-carboxylic acid derivatives are reported for determination of alkaline phosphatase (aPase) and codeine phosphate (CP). Complexation with terbium occurs by way of the oxygen atoms of the 4-hydroxyl group and the carbonyl group of the 3-carboxy function, respectively. The complexes are highly luminescent and do not require luminescence enhancers. The excitation maxima of the terbium chelates are at 320 nm. The assay is based on the quenching of the hypersensitive 545-nm luminescence of the terbium complexes with the ligands 4-hydroxy-1-methyl-2-oxo-1,2-dihydro-quinoline-3-carboxylic acid (5-ethyl-[1,3,4]thiadiazol-2-yl)-amide (L1) and 1-ethyl-4-hydroxy-2-oxo-1,2-dihydro-quinoline-3-carboxylic acid (4-trifluoromethyl-phenyl)-amide (L2) by phosphate ions. The assays require equimolar (1.0 μM) concentrations of Tb3+ and of the ligand at pH 8.0 (Tris–HCl buffer). The luminescence quenching is proportional to the concentration of aPase and CP within the range of 0.1–70 mU mL−1 and 0.3–20 μg mL−1, respectively. The detection limits were 0.05 mU mL−1 = 40.0 pmol L−1 of aPase and 0.120 μg mL−1 of CP. [ABSTRACT FROM AUTHOR] |
| Copyright of Annals of the New York Academy of Sciences is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
Be the first to leave a comment!