A novel technique for the characterization of a HPGe detector response based on pulse shape comparison
Saved in:
| Title: | A novel technique for the characterization of a HPGe detector response based on pulse shape comparison |
|---|---|
| Authors: | Crespi, F.C.L.1, Camera, F. camera@mi.infn.it, Million, B.1, Sassi, M.1, Wieland, O.1, Bracco, A.1 |
| Source: | Nuclear Instruments & Methods in Physics Research Section A. Aug2008, Vol. 593 Issue 3, p440-447. 8p. |
| Subjects: | Simulation methods & models, Signal detection, Detectors, Gamma rays |
| Abstract: | Abstract: A novel technique for measuring the HPGe detector pulse shape as a function of the γ-ray interaction position inside the detector volume is presented. This technique is based on a specific pulse shape comparison procedure. Its main feature is that it allows to characterize the 3D position response of a HPGe segmented detector in a much shorter time as compared with the standard coincidence techniques. The method was first validated using a GEANT simulation of a 36-fold HPGe AGATA detector realized taking into account the effects of the electronic chain response and electrical noise on the calculated signal shape. This procedure was then applied to extract experimentally the position response of a non-segmented coaxial HPGe detector along the radial direction, using a 438MBq 137Cs collimated γ-source. The results of this measurement show a dependence of the pulse shape as a function of γ-ray interaction radial coordinate consistent with that obtained with calculations. The signal acquisition rate reached using this characterization technique allows to realize a full scan of a large volume highly segmented HPGe detector in less than a week. [Copyright &y& Elsevier] |
| Copyright of Nuclear Instruments & Methods in Physics Research Section A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 33526890 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: A novel technique for the characterization of a HPGe detector response based on pulse shape comparison – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Crespi%2C+F%2EC%2EL%2E%22">Crespi, F.C.L.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Camera%2C+F%2E%22">Camera, F.</searchLink><i> camera@mi.infn.it</i><br /><searchLink fieldCode="AR" term="%22Million%2C+B%2E%22">Million, B.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Sassi%2C+M%2E%22">Sassi, M.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Wieland%2C+O%2E%22">Wieland, O.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Bracco%2C+A%2E%22">Bracco, A.</searchLink><relatesTo>1</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Nuclear+Instruments+%26+Methods+in+Physics+Research+Section+A%22">Nuclear Instruments & Methods in Physics Research Section A</searchLink>. Aug2008, Vol. 593 Issue 3, p440-447. 8p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Simulation+methods+%26+models%22">Simulation methods & models</searchLink><br /><searchLink fieldCode="DE" term="%22Signal+detection%22">Signal detection</searchLink><br /><searchLink fieldCode="DE" term="%22Detectors%22">Detectors</searchLink><br /><searchLink fieldCode="DE" term="%22Gamma+rays%22">Gamma rays</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Abstract: A novel technique for measuring the HPGe detector pulse shape as a function of the γ-ray interaction position inside the detector volume is presented. This technique is based on a specific pulse shape comparison procedure. Its main feature is that it allows to characterize the 3D position response of a HPGe segmented detector in a much shorter time as compared with the standard coincidence techniques. The method was first validated using a GEANT simulation of a 36-fold HPGe AGATA detector realized taking into account the effects of the electronic chain response and electrical noise on the calculated signal shape. This procedure was then applied to extract experimentally the position response of a non-segmented coaxial HPGe detector along the radial direction, using a 438MBq 137Cs collimated γ-source. The results of this measurement show a dependence of the pulse shape as a function of γ-ray interaction radial coordinate consistent with that obtained with calculations. The signal acquisition rate reached using this characterization technique allows to realize a full scan of a large volume highly segmented HPGe detector in less than a week. [Copyright &y& Elsevier] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Nuclear Instruments & Methods in Physics Research Section A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=33526890 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1016/j.nima.2008.05.057 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 8 StartPage: 440 Subjects: – SubjectFull: Simulation methods & models Type: general – SubjectFull: Signal detection Type: general – SubjectFull: Detectors Type: general – SubjectFull: Gamma rays Type: general Titles: – TitleFull: A novel technique for the characterization of a HPGe detector response based on pulse shape comparison Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Crespi, F.C.L. – PersonEntity: Name: NameFull: Camera, F. – PersonEntity: Name: NameFull: Million, B. – PersonEntity: Name: NameFull: Sassi, M. – PersonEntity: Name: NameFull: Wieland, O. – PersonEntity: Name: NameFull: Bracco, A. IsPartOfRelationships: – BibEntity: Dates: – D: 11 M: 08 Text: Aug2008 Type: published Y: 2008 Identifiers: – Type: issn-print Value: 01689002 Numbering: – Type: volume Value: 593 – Type: issue Value: 3 Titles: – TitleFull: Nuclear Instruments & Methods in Physics Research Section A Type: main |
| ResultId | 1 |